ETERNITY G16, G20, G26 Installation And Operating Instructions Manual

aternit
hot water solutions
by
CHRIMSIEN
EXTERNAL GAS HOT WATER UNIT
INSTALLATION AND OPERATING
INSTRUCTIONS
FOR ADVICE, REPAIRS AND
FAST SERVICE
1300 367 565
20501072(K)
INDEX
INSTALLATION INSTRUCTIONS
PAGE NO.
Introduction
1
Dimensions Connections
2
Exploded Diagram
3
Technical Data
4-5
Gas Connection
6
Cold Water Connection
7
Hot Water Connection
8
Electrical Requirements
8
Remote Controls
9
Remote Controls Wiring Diagram
10
Main Remote Control
11
Shower Remote Control
12
Mounting Remote Controls
13-14
User Instructions
15-17
Care of THE ETERNITY Hot Water Unit
18
Hints for Using THE ETERNITY Unit
19-23
Fault Monitor
24
Warranty Conditions
25
INTRODUCTION
ETERNITY G16/G20/G26
INSTALLATION INSTRUCTIONS
INTRODUCTION
The E I ERNTTY 16/20/26 is an external electronic gas hot water heater. The ETERNITY 16/20/26 is supplied set at a constant 60°C outlet temperature
depending on the model purchased. Three optional remote controls can be provided for complete hot water temperature selection and if this option is
used an approved temperature limiting device must be installed.
THIS HOT WATER UNIT IS NOT FOR
POOL OR SPA HEATING
GENERAL
1.0.1
The ETERNITY 16/20/26 must be installed in accordance with
(1)
These instructions;
(2)
Uniform Building Regulations Local authority regulations;
(3)
AS/NZS 3500.4"National Plumbing and Drainage Code, Part 4 Hot Water Supply Systems",
(4)
The Australian Gas Association installation code AS5601 for gas burning
appliances and equipment;
(5)
Any other statutory regulation that may apply;
(6)
A notice of intention to install shall be lodged with the relevant Municipal
Authority and local Gas Authority prior to installation.
INSTALLATION MUST BE CARRIED OUT ONLY BY AN AUTHORISED AND APPROPRIATELY LICENSED PERSON.
1.0.2 DELIVERY INSPECTION
The ETERNITY HOT WATER unit is supplied fully assembled for installation. The customer or installer upon delivery of the unit should immediately remove all packing materials and inspect the unit for damage and ensure that the unit supplied is correct for the gas supply to which it is to be connected, report any damage or discrepancies quoting to the supplier the serial number and model number, which can be found on the outside of the cabinet.
1
CABLE ENTRY POINT HOT WATER OUTLET
RP1/2/15
111M=1==All
PIFQ)
WATER INLET FILTER
GAS SUPPLY INLET
RP3/4/20
PRESSURE RELIEF VALVE
330
CABLE ENTRY POINT HOT WATER OUTLET
RP3/4/20
10111===YAN
[
pi=
Cr 25:
WATER INLET FILTER
GAS SUPPLY INLET
RP3/4/20
COLD WATER INLET RP3/4/20
PRESSURE RELIEF VALVE
330
COLD WATER INLET RP1/2/15
12
165
15
Model : 16/20
Model : 26
DIMENSIONS CONNECTIONS
2
III
J
/
o0 igo
IN
MirMaCEMIVACIBil
-
11E111
U
I
a
0 0
NOS. PARTS DESCRIPTION
1 FLUE OUTLET 2 GAS VALVE 3 CIRCUIT BOARD 4 BURNER CASE 5 HOT WATER OUTLET 6 COLD WATER INLET 7 GAS SUPPLY INLET 8 HEAT EXCHANGER
NOS. PARTS DESCRIPTION
1 FLUE OUTLET 2 GAS VALVE 3 CIRCUIT BOARD 4 BURNER CASE 5 HOT WATER OUTLET 6 COLD WATER INLET 7 GAS SUPPLY INLET 8 HEAT EXCHANGER 9 WATER VOLUME
PROPORTIONAL VALVE
0
0
Model : 16/20
Model : 26
0
0
0
0
EXPLODED DIAGRAM
2
3
1.1 TECHNICAL DATA AND DIMENSIONS ETERNITY 16 / 20 / 26
Nominal hourly gas consumption MJ/h
MODEL 16 20 26
by proportional electronic gas control
MJ/h
125 160 200
Test point pressure
MODEL NG LP
Water heating capacity raised 40°C
MODEL 16 20 26 ML/M 10 12.5 16.25
Working pressure
Max 1200kPa
Gas injectors of the following size in mm
MODEL NG LPG MODEL NG LPG
are fitted for the approved gas types
16/20 1.35 1.35 mm 26
1.34 1.0mm
1.65 1.65 mm
1.65 1.2 mm
Input voltage single phase 50Hz
240V
Maximum output current
MODEL 16 20 26 Amp0.37 0.45 0.47
SAIG Approval certificate no.
MODEL 16/20 GSCS 20021
26 GSCS 20021
Inlet gas connection male thread
18mm
Cold water connection male thread
MODEL 16/20 13mm
26 18mm
Hot water connection male thread
MODEL 16/20 13mm
26 18mm
Relief valve pressure setting
14001cPa
Weight dry
MODEL 16/20 16kg
26 17kg
1.2 DATA PLATE
Left outside of cabinet
1.3 GAS TYPE
The temporary gas label is located on the cabinet top. The label is the gas that this appliance is designed to operate with.
16 20 26
.40
.40
.56
.61
.68
.70
DO NOT OPERATE WITH ANY OTHER GAS TYPE.
TECHNICAL DATA
4
1.4
HEATER DIMENSIONS:
DEPTH
165mm WIDTH 350mm HEIGHT
575mm
1.5
WARNING LABELS
Located on the side of the cabinet. PLEASE READ THESE LABELS CAREFULLY.
1.6
INSTALLATION POSITION
THIS HEATER IS APPROVED FOR OUTDOOR INSTALLATION ONLY-IT IS NOT SUITABLE FOR INDOOR USE.
Refer AS5601 for clearance details for flue terminal.
In addition,ensure that the appliance installation position permits easy access for
maintenance and operation.
For further infomation,please refer to the Gas Fitting Regulations.
1.7 POSITION FOR INSTALLATION
The heater must be installed by using a fixing method sufficient to hold the weight of the unit (see the technical sheet for dimensions of mounting brackets and positions).
TECHNICAL DATA
5
1.8 GAS CONNECTION
(1)
Fit a union to the water heater gas inlet for easy connection and removal. The thread diameter is 18mm. THIS DOES NOT INDICATE THE SIZE OF THE GAS SUPPLY
refer to AS5601
for
guidance on pipe sizing.
(2)
Fit an AGA approved isolating gas cock in the supply line adjacent to the water heater gas connection.
(3)
Ensure that the supply pipe and the gas pressure regulator(LPG or NaturalGas) has sufficient flow capacity for this and other appliances connected to the fitting line.
(4)
For LPG appliances ensure that gas cylinders are of sufficient size.The water heater alone
will require a regulator of 4KG per hour capacity.
(5)
Before connecting the appliance to the gas service purge any debris or air from the gas service. Venting of purged gas shall be an area free of sources of ignition.
Close the isolating gas cock prior to connection of the appliance.
(6)
After connection check all joints for leaks with an approved leak tester.
Refer to
AS5601
Installation Code for pipe sizing details. For your assistance we have
included the following pipe sizing from
AS5601
for copper tube using Natural Gas.
NOMINAL PIPE
SIZE IN mm
STRAIGHT LENGTH OF
PIPE METRES
HOURLY RATE
IN MJ/h
13
4
43.0
18
4
82.2
20
4
142.0
25
4
313.0
THE ETERNITY 16/20/26 REQUIRES A MINIMUM OF 125/160/200 MJ/h FOR THE CUSTOMER TO OBTAIN THE FULL PERFORMANCE BENEFIT.
SERVICE CALLS ARE CHARGEABLE FOR
UNITS WITH INCORRECT GAS PIPE SIZES.
GAS CONNECTION
6
COLD WATER CONNECTION
1.9 COLD WATER SUPPLY TO WATER HEATER
Refer to the Technical Sheet for the position of connections. Minimum of 13mm for model
16/20 and 18mm for model 26 copper tube should be connected to the appliance . The WATER INLET connection are 13mm BSP for model 16/20 and 18mm BSP for model 26 and requires a union to allow for removal of the water heater. Pipe sizing from the cold water supply should be sized according to local BY LAWS for water supply.
ISOLATING GATE VALVE or BALL VALVE A GATE VALVE or BALL VALVE must be used on the cold water inlet to the water
heater. THIS REQUIREMENT IS AN AUSTRALIA WIDE REQUIREMENT UNDER THE NATIONAL PLUMBING CODE.
IF THE ABOVE INSTRUCTION IS NOT CARRIED OUT ALL WARRANTIES ON THE UNIT WILL BE VOIDED.
STOP TAPS OR COMBINATION STOP TAPS AND NON-RETURN VALVES ARE NOT TO BE USED!
N.B. NO PRESSURE REDUCTION VALVE IS
REQUIRED UNLESS THE INLET WATER PRESSURE EXCEEDS 1400kPa AT ANY TIME OF THE DAY. EG
EARLY HOURS OF THE
MORNING.
HOT WATER CONNECTION
2.0 Refer to Technical Sheet for the position of connection. The outlet connection is 13mm for model 16/20 and 18mm for model 26 male thread and requires an isolating union to allow for removal of the unit.
2.1 Install the hot water supply line to the unit in a minimum of 13mm
for model
16/20 and 18mm for model 26
copper tube. for units set at 50°C this must be a
minimum of Four (4) Metres to the first outlet.
2.2 Keep the pipe lengths to a minimum and make sure that the pipework is well insulated, as correct performance of the appliance is dependent on properly insulated pipework.
2.3 DO NOT FIT ANY VALVES OR RESTRICTORS TO THE OUTLET OF
THE WATER HEATER.
2.4 DO NOT FIT ANY OBSTRUCTION TO THE PRESSURE RELIEF
LOCATED ON THE HOT WATER OUTLET CONNECTION.
2.5 After purging the air from the system using the hot water supply taps, remove
the water inlet strainer located on the cold water supply inlet connection. Remove any debris from the filter and replace. When replacing the filter do not over tighten the"O"ring seal.
ELECTRICAL REQUIREMENTS
3.0 The appliance is equipped with a three pinned earthed plug to be connected to a 220-240V 50Hz power supply. The electrical rating of the appliance is
0.37/0.45/0.47Amp.for the ETERNITY 16/20/26
3.1 The appliance requires a 240V 50Hz weatherproof power outlet installed in a protected position adjacent to the appliance.
3.3 IMPORTANT: The appliance should always be disconnected from the power supply before any maintenance is carried out.
8
Refer to Technical Sheets
4.0 The ETERNITY 16/20/26 comes complete, with one, two or three remote control panels, as optional extras.
ONE REMOTE CONTROLS SYSTEM
MODEL
CMR-154
MAIN CONTROLS
TWO OR THREE REMOTE
MODEL
CMR-154
MAIN CONTROLS
CONTROLS SYSTEM
MODEL
YST-84
SHOWER CONTROLS
MODEL
YST-84S
ENSUITE CONTROLS
4.1 These controls are to be fitted in the following locations:
* MAIN CONTROLS-kitchen or laundry * SHOWER CONTROLS-main bathroom
IMPORTANT DO NOT locate the remote controls where they may come into contact with water. DO NOT position the remote controls in the vicinity of chemicals. DO NOT position the remote controls over a cooker, grill oven or toaster. DO NOT position the remote controls where materials may spill onto them.
4.2 MAIN REMOTE CONTROLS CMR-154 The main remote controls is fitted using the mounting holes in the rear of the casing.
Wiring is from the rear using the wiring hole provided in the casing.
4.3 SHOWER REMOTE CONTROLS YST-84 & ENSUITE REMOTE CONTROL YST-84S These remote controls have a self adhesive backing plate which can be adhered to any
clean dry surface. These controls must also be wired from the rear, leave sufficient
wire for disconnection and removal.
4.4 CONNECTION OF WIRING TO THE ETERNITY
Remove the front cover from the unit. Install the wiring to the ETERNITY 16/20/26 main unit using conduit or by concealing
the wires in the wall cavity. Install the wiring into the cabinet through the wiring access adjacent to the power cable, see the Technical Sheet.
4.5
Using the cable clamps provided on the plate adjacent to the terminal block attach the wiring to the plate. Then attach the wires to the terminals for the remote controls. See wiring diagram next page. Replace the front cover and connect the power plug.
4.6 COMMISSIONING AND TESTING After completing the installation of the unit, turn the water, power and gas supplies on to the
unit. CONTROLS OPERATION
Turn the main remote controls ON by pressing the ON/OFF switch on the controls to the ON position.
The MAIN REMOTE CONTROLS will indicate the 42°C and the MAIN CONTROLS light will be alight.
Using the UP/DOWN buttons select the hot water temperature required. Turn on the hot water supply tap. The burner light glowing will indicate that hot water is being supplied. Move to the shower controls (if fitted). Press the TRANSFER BUTTON and repeat the procedure. Move to the En Suite controls (if fitted). Press the TRANSFER BUTTON and repeat the procedure.
THERE ARE NO MINOR ADJUSTMENTS THAT CAN BE MADE TO THE UNIT.
REMOTE CONTROLS
9
ORO.
IN
c-1
,[71•H,
a
TERMINALS FOR
REMOTE CONTROLS
CABLE CLAMP
-1aPj=f,
I
o
CABLE ENTRY PORT REMOTE CONTROLS CABLE
ANTI-FREEZE HEATER
WIRING DIAGRAM OF PCB
TURN OFF POWER SUPPLY TO HOT WATER UNIT AND REMOVE PLUG FROM POWER OUTLET BEFORE REMOVING FRONT COVER OF HOT WATER UNIT.
WIRING FROM MAIN UNIT TO MAIN & SHOWER/SUB REMOTE CONTROLS
MAIN CONTROL
SHOWER CONTROL
240volt POWER SUPPLY
SUB CONTROL
(ENSUITE)
1
REMOTE CONTROLS WIRING DIAGRAM
10
MAIN REMOTE CONTROL
CMR-154
16
f
ON
(I)
\
(
AL M
AM
17 1'
1 • 17 17 t
PMCILI•ULD
rr
j
4-1 Fi-1
U6FF
i(1.
:.:..
...
:
o
.....°:
t..
.1
KITCHEN
CMR- 154
?
TIME SET
I
dlArrEtrnott
mtealuttatettretcoarigit.*:
hat. artdb.mst
y
t, onvittnet.tere,pkatekter
0.16,1111,t7 frvadcorfrratewta
ts-o_
to el°
1 a
7 4
5
8
3
2
9
NOS.
CONTROL
FUNCTION
1
DIGITAL DISPLAY
INDICATES TEMPERATURE & TIME ERROR CODE WHEN SAFETY DEVICE ON
2
TEMPERATURE CONTROL
ADJUSTS TEMPERATURE BETWEEN 37°C TO 75°C
3
TRANSFER INDICATOR
INDICATES THIS CONTROL HAS PRIORITY
(GREEN)
(CAN ADJUST TEMPERATURE ONLY WHEN)
THE INDICATOR IS ILLUMINATED
4
ON INDICATOR(GREEN) INDICATES POWER IS ON TO SYSTEM
5
ON/OFF SWITCH POWER SWITCH TO OPERATE THIS CONTROL
6
COMBUSTION LAMP(RED)
INDICATES A HOT WATER TAP IS BEING OPERATED
7
ALARM LAMP(RED)
FLASHES IN ABNORMAL CONDITION
8
TIME SETTING LAMP(GREEN)
INDICATES THAT THE TIME SETTING IS IN PROCESS
9
TIME SETTING SWITCH PUSHES WHEN SETTING THE TIME
MAIN REMOTE CONTROLS
11
SHOWER / SUB REMOTE CONTROLS
YST-84 /YST-84S
16
C
ALM
(.„
LA
[
AM
rf TI
PM
Li LI
•nrit
LI 11 Pt 1
Ell In
r---
,
. . .
TRANSFE1
11
nn
ILM
f:---
°11
BATHROOM
,
ON/OFF
YST-84
o....
O.:':
Fa sa-ery erd pew usg Ice areto rend
te.e.e.
Arremox
11.02.Mry cacd,,,:edetrk,i, PM,. *arr.
xla
7
3-A
3
4 5
3-B 2
(ILLUSTRATION IS FOR YST-84)
NOS. CONTROL
1
DIGITAL DISPLAY
2 TEMPERATURE CONTROL
3 TRANSFER SWITCH
(GREEN)
3-A TRANSFER INDICATOR
(GREEN)
3-B TRANSFER INDICATOR
(GREEN "T" LAMP)
4
ON INDICATOR(GREEN)
5
ON/OFF SWITCH
6 COMBUSTION LAMP(RED)
7 ALARM LAMP(RED)
FUNCTION
INDICATES TEMPERATURE & TIME ERROR CODE WHEN SAFETY DEVICE ON
ADJUSTS TEMPERATURE BETWEEN 37°C TO 48°C
PUSHES TO SET PRIORITY TO THIS CONTROL
INDICATES THIS CONTROL HAS PRIORITY
INDICATES THIS CONTROL HAS PRIORITY
INDICATES POWER IS ON TO SYSTEM
POWER SWITCH TO OPERATE THIS CONTROL
INDICATES A HOT WATER TAP IS BEING OPERATED
FLASHES IN ABNORMAL CONDITION
SHOWER/SUB REMOTE CONTROLS
12
MOUNTING AND WIRING OF REMOTE CONTROLS
4.7
REMOTE CONTROLS
OPEN THE CARTON BOX AND MAKE SURE TO CHECK FOLLOWING PARTS PROVIDED.
MAIN CONTROLS MODEL CMR-154
,,,---
j-------------
V
01"
\--,_____
2PCS
2PCS
REMOTE CONTROLS WOOD SCREW
CURL PLUG
WIRING
SHOWER/SUB CONTROLS MODEL YST-84 / YST-84S
''''
1111'11
'11A
-.•-
c
r
2PCS
04"
2PCS
41111°
2PCS
REMOTE CONTROLS
WOOD SCREW
CURL PLUG
CONNECTOR
(C
:1D
---
4
‘-----__
_____,-,
WIRING CABLE CLAMP
MOUNTING REMOTE CONTROLS
13
FRONT COVER
WOOD SCREW
FRONT COVER
REMOTE CONTROL
METAL BRACKET
METAL BRACKET
ALTERNATIVES IN MOUNTING REMOTE CONTROLS
IN EITHER OF THE FOLLOWING TWO ALTERNATIVES, YOU ARE TO REMOVE METAL BRACKET ATTACHED TO THE BACK OF EACH REMOTE BY SLIDING THE BRACKET FIRMLY DOWN TILL IT IS RELEASED FROM THE NOTCH BY CLICK, THEN PULL IT
OUT.(MAIN CONTROL ONLY) SINCE SHOWER/SUB CONTROLS WATERPROOFED, PLEASE INSTALL ON DIRECT
MOUNTING.
A. USING THE BRACKET (BEING REMOVED AS ABOVE) AS A FIXTURE:
(REFER THE DIAGRAM BELOW)
1.
FIX THE BRACKET TO THE WALL WITH WOOD SCREWS PROVIDED USING ANY TWO HOLES OUT OF THE SIX HOLES PROVIDED TO THE BRACKET.
2.
FASTEN WIRING TO THE TERMINAL BLOCK.
3.
FIX THE REMOTE CONTROLS TO THE BRACKET CATCHING THREE NAILS OF THE BRACKET THROUGH NOTCH AND THEN SLIDING FROM ABOVE FIRM UNTIL IT CATCHES THE NOTCH IN THE BRACKET AND CLICKS.
B. DIRECT MOUNTING
(REFER THE DIAGRAM BELOW)
1. REMOVE THE FRONT COVER OF THE CONTROLS USING SCREWDRIVER CAREFULLY EASING THROUGH THREE SLOTS IN TURN PROVIDED AT THE TOP OF THE CONTROLS.
2.
FASTEN WIRING TO THE TERMINAL BLOCK.(PLEASE SKIP THIS PROCESS IN CASE OF SHOWER/SUB CONTROLS.)
3.
FIX THE REMOTE CONTROLS BASE BY WOOD SCREWS PROVIDED THROUGH TWO HOLES AT THE BOTH SIDE OF THE BASE. THEN FIT THE FRONT COVER IN PLACE.
14
ON
`4
27n
{I
V II
A
1]
ILTRAI7ER1
v
ON
2ui
A j
..w-
ON/OFF
USER INSTRUCTIONS
PLEASE HAND THIS HANDBOOK TO THE USER AFTER INSTALLATION. INTRODUCTION:
You have selected the ETERNITY electronic gas hot water unit. The following instructions will assist you to obtain the best performance from your ETERNITY unit.
OPERATION: Up to three remote controls are able to be installed with your ETERNITY unit for complete controls of your hot water. Please note units without remote control will be set at 60°C or in the case of commercial units 75°C.
OPERATION OF MAIN REMOTE CONTROLS
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USING THIS APPLIANCE.
1.
TURN ON THE ON/OFF SWITCH (REFER PG 11 OF THIS MANUAL).
2.
THE TEMPERATURE DISPLAY WILL ILLUMINATE AT 42°C.
3.
THE "T" AND ON INDICATORS WILL ILLUMINATE.
4.
SELECT HOT WATER TEMPERATURE BY PRESSING UP / DOWN BUTTONS ON THE
CONTROLS.
5.
TURN ON A HOT WATER TAP. COMBUSTION INDICATOR WILL ILLUMINATE AFTER A SHORT DELAY, ON BOTH REMOTE CONTROLS. THESE INDICATORS WILL REMAIN ILLUMINATED UNTIL THE HOT WATER TAP IS TURNED OFF.
• MAIN CONTROL
• SHOWER/SUB CONTROLS
6.
THE HOT WATER TEMPERATURE CAN BE ALTERED AT ANY TIME DURING THE
OPERATION BY USING THE UP/DOWN BUTTONS LOCATED ON
.
THE CONTROLS.
USER INSTRUCTIONS
15
OPERATION OF SHOWER / SUB REMOTE CONTROLS
The SHOWER/SUB CONTROLS overrides the operation of the main control. Leave the operation switch on the MAIN CONTROL switched ON.
YST-84/84S SHOWER/SUB CONTROLS
1.
Press the ON/OFF button after opening the cover on the CONTROLS. See diagram 1 below.
2.
Press the TRANSFER BUTTON and the TRANSFER light will illuminate and the TEMPERATURE DISPLAY will have 42°C displayed. Please refer to page 12 of this handbook. See diagram 2 below.
3.
Using the UP/DOWN BUTTONS select the temperature required. See diagram 3 below.
4.When you have finished using the hot water supply press the TRANSFER BUTTON to return the controls back to the MAIN CONTROL.
DIAGRAM 1
DIAGRAM 2
DIAGRAM 3
USER INSTRUCTIONS
16
HINTS FOR USING REMOTE CONTROLS
FOR SAFETY AND ENERGY SAVINGS
1.
Set the MAIN CONTROL to 42°C for normal household use and to prevent small children
from scalding.
2.
For the dishwasher set the MAIN CONTROL to 60°C or the temperature in the manufacturer's
instructions.
3.
For showering use settings between 37°C-39°C and no cold water will be needed to be mixed,
and if other hot or cold water taps are used the temperature will be maintained.
THE TEMPERATURE WILL INCREASE BY 1°C WITH EACH PRESS OF THE UP/DOWN BUTTONS. THE TEMPERATURE CAN BE ADJUSTED CONTINUOUSLY BY KEEPING THE BUTTON PRESSED. OVER 50°C UP TO 75°C, THE TEMPERATURE IS CONTROLLED BY 5-°C NOTCH.
PLEASE NOTE ABOVE 50°C SCALDING CAN OCCUR WITHIN SECONDS
4.
The MAIN REMOTE CONTROL is left switched on at all times for operation.
5.
The MAIN REMOTE CONTROL is left switched on at all times and then change can be made
to the operation temperature at any time during operation of hot water taps.
17
1.
2.
3.
DO NOT HANG WASHING OR OTHER MATERIALS ADJACENT TO THE UNIT.
DO NOT STORE INFLAMMABLE MATERIALS WITHIN 2 METERS OF THE UNIT.
DO NOT TOUCH THE FLUE OUTLET OF THE UNIT DURING OR IMMEDIATELY AFTER OPERATION.
IF ANY GAS SMELL COMES FROM THE UNIT,
DO NOT USE NAKED FLAMES
TO TEST FOR GAS LEAKS.
TURN OFF THE GAS SUPPLY AND POWER AND CONTACT YOUR
GAS SUPPLY COMPANY.
6.
IF A POWER FAILURE OCCURS THE REMOTE CONTROLS WILL NOT FUNCTION AND
THE CHOFU UNIT WILL NOT SUPPLY HOT WATER UNTIL POWER IS RESTORED.
WHEN POWER IS RESTORED THE REMOTE CONTROLS WILL RESET AT 42°C AS A SAFE TEMPERATURE.
PLEASE NOTE
4.
5.
CARE OF THE ETERNITY UNIT
18
Close
Prohibited
No Fire
POINTS NEEDED FOR YOUR SPECIAL ATTENTION
,L
Danger
NO INSTALLATION INDOORS
(May cause oxygen deficiency accident or incomplete combustion.)
The unit is outdoor installation type. Never install indoor or in the bathroom. It will be extremely dangerous since it will cause oxygen deficiency and incomplete combustion. Prohibited
,AWarning
WATCH FOR GAS LEAK
May cause fire.)
When gas leak is noticed, stop using the unit immediately and close the gas valve, then contact the shop you bought the unit from or the gas supply company.
CONFIRM TYPE OF GAS AND POWER SUPPLY
(May cause incomplete combustion, explosive ignition or fire.)
0
Check
ETERNITY G16 EXTERNAL GAS WATER
HEATER
ETERNITY G20 EXTERNAL GAS WATER
HEATER
ETERNITY G26 EXTERNAL GAS WATER
HEATER
SAIL APPROVAL No.
GSCS20021
NAT.G
°
a
0
5
CAN
Safety 8
Certified
n54553
SAI Global
SAIG APPROVAL No.
GSCS20021
NAT.G
A
rmi
5
VeY,
GaS Safety
8
Certified
AS
4558
SAI Global
SAIL APPROVAL No.
GSCS20021
NAT.G
m
.. , A
Gas Safely 8
Certified
As 4552
SA1 Global
INPUT
M1/11
OUTPUT
kW/M1
125
27.8
INPUT
M.1/11
OUTPUT
kW/h
160
365
INPUT
M.1/11
OUTPUT
kW/M1
200
94.4 TEST POINT PRESSURE HIGHkPa TEST POINT PRESSURE LOWkPa
0.40
G103
TEST POINT PRESSURE HIGHkPa TEST POINT PRESSURE LOW
kPa
0.56
0.103
TEST POINT PRESSURE HIGH
kPa
TEST POINT PRESSURE LOWkPa
0.68
0.118
GAS INJECTORS
rnrn
135/1.65
GAS INJECTORS
1,,r11
1.35,1.55
GAS INJECTORS
rnm
1.34/1.65
WEIGHT
kg
MAX WATER PRESSURE
kPa
ISO 1200
WEIGHT
kg
MAX WATER PRESSUREkPa
16.0 1200
WEIGHT
kg
MAX WATER PRESSUREkPa
17.0
1200
MIN. WATER PRESSUREkPa
260
KN. WATER PRESSUREkPa
260
MIN. WATER PRESSUREkPa
210 WATER HEATING CAPACITY 10.01/min RAISED VOLTAGE 240 Volts-50Hz 0.37AMPS
400
WATER HEATING CAPACITY 1 2.51/min RAISED VOLTAGE 240 Volts-SOHz 0.45AMPS
400
WATER HEATING CAPACITY 1 G251./min RAISED 400 VOLTAGE 240 Volts-50Hz 0.47AMPS
20541310
20541330
20541350
SERIAL No. SERIAL No.
SERIAL No.
Make sure to use the gas type as well as power supply (voltage/frequency) as indicated on the RATING LABEL located on the cabinet side. There are Natural Gas and Propane Gas on the GAS TYPE LABEL.
HINTS FOR USING THE ETERNITY UNIT
19
Warning
NO DISASSEMBLY, REPAIR OR
MODIFICATION (May cause fire, electric shock or other
accidents.)
414
No Disassemble
r
0
,3
CJ
Do not dissemble or modify the units. Never fail to ask professional assistance from the dealer you have bought your unit from for such a case as installation, removing, auxiliary installation work or connection to the solar units.
CAUTION FOR INFLAMMABLE ITEMS (May cause fire or explosion.)
4.1
C==
()
Do not place any inflammable items such as gasoline or benzene nor use them around the unit.Take special care.
O
L
Warning
Freeze Prevention.
This unit comes equipped with electric heaters that discourage the water heater from frerzing. To enable this freeze prevention system to operate there must be an electrical power supply connected to the unit. The freeze prevention devices will not operate if the electrical power source is not connected.
Caution.
The electric heaters are installed inside the water heater only all External Hot and Cold water supply pipes and fittings connected to the water heater should be properly insulated.
O
O
20
Close
Close
Pull
No wet hand
Warning
CAUTION TO PREVENT SCALDING
Check the water temperature by hand first before using shower.
MEASURE TO BE TAKEN IN CASE OF EMERGENCY
When there is an emergency such as earthquake or fire, apply following procedure.
1.
Close the hot water outlet.
2.
Close the gas valve and the main water valve.
3.
Turn off the main power.
However, in case of gas leakage, first close the gas valve then wait for the leaked gas to disperse
then turn off the main power supply.
4.
Contact the dealer from whom you bought the unit.
Caution
21
Caution
DANGER OF WET HANDS
INSERT POWER PLUG PROPERLY INTO
(May cause electric shock.)
TERMINAL
Do not touch power plug with wet hands. It is dangerous, because it can cause electric shock.
Check the power plug for dust accumulation, then properly insert to the power point.
DO NOT PULL POWER CORD
(May generate heat and cause fire.)
DO NOT USE POWER CORD BUNDLED
(May generate heat and cause fire.)
Do not turn off the power plug by pulling the cord. It may generate heat by wire breakage then cause fire.
If the power supply cord is damaged,it should be replaced by a cord available from
ETERNITY Agents.
Never use power cord in a bundled condition. It will cause heat generation and fire.
4•
Warning
Prohibited
Prohibited
Check
22
° 11_4_11
ON/Ofj
ON
v
A
J
'TRANSFER
Check
Caution
CONFIRM IGNITION, COMBUSTION AND EXTINCTION
Please always check ignition, combustion and extinction of the unit by the operation lamp of the main or shower/sub remote controls.
DO NOT PUT WATER ON THE
DO NOT INSTALL NEAR ELECTRIC
REMOTE CONTROLS
APPLIANCES
(May cause failure.)
Check
Do not put water on the remote controls.
When installed near to TV or radio, it may cause
It will cause failure.
picture disturbance or sound disturbance. Install away from those appliances.
Instant overflow voltage caused by lightn ng can Make sure to secure good enough space around damage the electronic parts. Therefore, to
n off
the unit to ensure space necessary for checking
the main power when you have thunder.
and maintenance.
SECURE SERVICE SPACE
Check
MEASURE TO BE TAKEN FOR LIGHTNING POSSIBILITY
(May cause failure.)
Pull
No wet hand
23
FAULT MONITOR
THE ETERNITY HOT WATER UNIT HAS A SELF DIAGNOSING FUNCTION FOR FAULTS.
When the unit does not operate correctly, an error code is displayed on the MAIN and SHOWER remote controls TEMPERATURE DISPLAY INDICATOR. The cause of the fault can be determined after checking the fault numbers display on the remote control display.
DISPLAY
PROBLEM
REMEDY
11
GAS BURNER FAILS TO IGNITE.
CHECK GAS SUPPLY.
72
FALSE FLAME DETECTION. CALL SERVICE CENTRE.
12
LOSS OF COMBUSTION.
CHECK GAS SUPPLY AND PRESSURE.
14
RESIDUAL FLAME SAFETY
CALL SERVICE CENTRE.
DEVICE.
32
THERMISTOR WIRE BREAKAGE. CALL SERVICE CENTRE.
61
COMBUSTION FAN FAILURE. CALL SERVICE CENTRE.
740
COMMUNICATION FAILURE
TURN OFF POWER AND TURN
750
BETWEEN REMOTE CONTROLS
ON AGAIN.
760
&
PCB.
PLEASE NOTE REPLACENT POWER CODE FOR THIS APPLIANCE CAN BE OBTAINED FROM THE ETERNITY SERVICE DEPARTMENT TELEPHONE 1300367565.
PLEASE NOTE ONLY AUTHORISED PERSONS ARE TO PERFORM SERVICE WORK ON THIS APPLIANCE FAILURE TO OBSERVE THIS CONDITION WILL VOID THE WARRANTY AND COULD MAKE THE APPLIANCE UNSAFE.
SCHEDULED SERVICE PERIODS
This water heater requires scheduled maintenance at regular 12 monthly periods to obtain the
maximum service life and safe operation.
FAULT MONITOR
24
Eternity Continuous Flow
1.
All Eternity water heaters must be installed by a Licensed installer.
2.
Only Authorised personnel must Install, Commission or Service Eternity water heaters.
3.
All Eternity water heaters must be installed in accordance with Manufacturer's Installation Instructions and in Accordance with local regulations, municipal building codes and current AS/NZS3000, AS/NZS3500, AS 3498 and AS5601.
4.
If the Eternity water heater has not been installed in accordance with Manufacturer's Installation Instructions or installed as to be easily accessable for servicing, a service charge may apply.
5.
Where a component may have failed under warranty and is replaced, the component replaced will only be covered by the warranty for the balance of the appliance warranty period.
6.
Water Quality must be within limits specified in table below.
pH
Sodium
T
(Total DSDissolved
Solids)
Chlorides
Iron
Magnesium
Alkalinity
(as CaCO3)
Dissolved
(free) CO2
Tot
Hardne
al
ss
CaCO3
6.5
to
8.5
Up
to
150
mg/litre
Or
ppm
Up to
600
mg/litre
or
ppm
Up to 300
mg/litre
or
ppm
Up to 1
mg/litre
or
ppm
Up to 10
mg/litre
or
ppm
Up to
200
mg/litre
or
ppm
Up to
25
mg/litre
or
ppm
Up to
200
mg/litre
or
ppm
The warranty will be rendered void in the following circumstances:
1.
Failure due to misuse, Acts of God, accidental damage, installation by an
installer who is not unauthorised to install an Eternity water heater or incorrect installation and attempts to repair Eternity by an unqualified person.
2.
Repairs and service carried out by a person who is not a Qualified Service Person
or Authorised Service Agent.
3.
Faults caused by incorrect installation, water problems, electricity supply and or
gas supply.
The warranty does not cover the following:
4.
Subject to any statutory provisions to the contrary, claims for damages to walls, foundations etc or any other consequential loss caused either directly or indirectly by leakage from the water heater or any other faults.
5.
Warranty does not cover any faults that may arise from connecting to a water
source that is unfiltered such as dams, bores, rivers etc.
Eternity does not accept liability for consequential damage or any incidental expenses resulting from any breach of the Warranty.
WARRANTY CONDITIONS
25
Warranty Terms
Eternity Water Heaters are covered by Eternity for any cost of labour and parts in the event of a component failure due to any defects that may arise either from workmanship and or faulty material.
The Warranty commences on the date of Installation:
Domestic Appliance
Eternity Product
Heat Exchanger
Parts
10 Years
Labour
3 Years
All Other Parts
.
Parts
3 Years
Labour
3 Years
Commercial Application
Eternity Product
Heat Exchanger
Parts
5 Years
Labour
1 Year
All Other Parts
Parts 1 Year
Labour
1 Year
Definition of Domestic Use:
1.
Units installed in any domestic dwelling.
2.
Units installed in any gas boosted solar system in a domestic dwelling.
3.
Units used in any household applications.
Definition of Commercial Use:
1.
Units supplying kitchen areas used for bulk food preparation.
2.
Units used in industrial or bulk heating processors and hydronic heating installations.
3.
Units used as bulk central heating systems and flow and return systems.
Please contact your ETERNITY office for full warranty conditions
On 1300 367 565 for all Warranty and Service information.
Loading...