EXTERNAL GAS HOT WATER UNIT
INSTALLATION AND OPERATING
INSTRUCTIONS
MODELS G16/G20/G26
FOR ADVICE, REPAIRS AND
FAST SERVICE
1300 367 565
20501072(K)
![](/html/55/555c/555ce2a2e4ffe3fe665ae5dec584d94bb8ced1d6dd807b84940471484ccc62e0/bg2.png)
INDEX
INSTALLATION INSTRUCTIONS
PAGE NO.
Introduction
1
Dimensions Connections
2
Exploded Diagram
3
Technical Data
4-5
Gas Connection
6
Cold Water Connection
7
Hot Water Connection
8
Electrical Requirements
8
Remote Controls
9
Remote Controls Wiring Diagram
10
Main Remote Control
11
Shower Remote Control
12
Mounting Remote Controls
13-14
User Instructions
15-17
Care of THE ETERNITY Hot Water Unit
18
Hints for Using THE ETERNITY Unit
19-23
Fault Monitor
24
Warranty Conditions
25
![](/html/55/555c/555ce2a2e4ffe3fe665ae5dec584d94bb8ced1d6dd807b84940471484ccc62e0/bg3.png)
INTRODUCTION
ETERNITY G16/G20/G26
INSTALLATION INSTRUCTIONS
INTRODUCTION
The E I ERNTTY 16/20/26 is an external electronic gas hot water heater.
The ETERNITY 16/20/26 is supplied set at a constant 60°C outlet temperature
depending on the model purchased. Three optional remote controls can be
provided for complete hot water temperature selection and if this option is
used an approved temperature limiting device must be installed.
THIS HOT WATER UNIT IS NOT FOR
POOL OR SPA HEATING
GENERAL
1.0.1
The ETERNITY 16/20/26 must be installed in accordance with
(1)
These instructions;
(2)
Uniform Building Regulations Local authority regulations;
(3)
AS/NZS 3500.4"National Plumbing and Drainage Code, Part 4 Hot Water
Supply Systems",
(4)
The Australian Gas Association installation code AS5601 for gas burning
appliances and equipment;
(5)
Any other statutory regulation that may apply;
(6)
A notice of intention to install shall be lodged with the relevant Municipal
Authority and local Gas Authority prior to installation.
INSTALLATION MUST BE CARRIED OUT ONLY BY
AN AUTHORISED AND APPROPRIATELY LICENSED PERSON.
1.0.2
DELIVERY INSPECTION
The ETERNITY HOT WATER unit is supplied fully assembled for installation.
The customer or installer upon delivery of the unit should immediately remove all
packing materials and inspect the unit for damage and ensure that the unit supplied
is correct for the gas supply to which it is to be connected, report any damage or
discrepancies quoting to the supplier the serial number and model number, which
can be found on the outside of the cabinet.
1
![](/html/55/555c/555ce2a2e4ffe3fe665ae5dec584d94bb8ced1d6dd807b84940471484ccc62e0/bg4.png)
CABLE ENTRY POINT
HOT WATER OUTLET
RP1/2/15
111M=1==All
PIFQ)
WATER INLET FILTER
GAS SUPPLY INLET
RP3/4/20
PRESSURE RELIEF VALVE
330
CABLE ENTRY POINT
HOT WATER OUTLET
RP3/4/20
10111===YAN
[
pi=
Cr 25:
WATER INLET FILTER
GAS SUPPLY INLET
RP3/4/20
COLD WATER INLET RP3/4/20
PRESSURE RELIEF VALVE
330
COLD WATER INLET RP1/2/15
12
165
15
Model : 16/20
Model : 26
DIMENSIONS CONNECTIONS
2
![](/html/55/555c/555ce2a2e4ffe3fe665ae5dec584d94bb8ced1d6dd807b84940471484ccc62e0/bg5.png)
III
J
/
o0 igo
IN
MirMaCEMIVACIBil
-
11E111
U
I
a
0 0
NOS. PARTS DESCRIPTION
1 FLUE OUTLET
2 GAS VALVE
3 CIRCUIT BOARD
4 BURNER CASE
5 HOT WATER OUTLET
6 COLD WATER INLET
7 GAS SUPPLY INLET
8 HEAT EXCHANGER
NOS. PARTS DESCRIPTION
1 FLUE OUTLET
2 GAS VALVE
3 CIRCUIT BOARD
4 BURNER CASE
5 HOT WATER OUTLET
6 COLD WATER INLET
7 GAS SUPPLY INLET
8 HEAT EXCHANGER
9 WATER VOLUME
PROPORTIONAL VALVE
0
0
Model : 16/20
Model : 26
0
0
0
0
EXPLODED DIAGRAM
2
3
![](/html/55/555c/555ce2a2e4ffe3fe665ae5dec584d94bb8ced1d6dd807b84940471484ccc62e0/bg6.png)
1.1 TECHNICAL DATA AND DIMENSIONS ETERNITY 16 / 20 / 26
Nominal hourly gas consumption MJ/h
MODEL 16 20 26
by proportional electronic gas control
MJ/h
125 160 200
Test point pressure
MODEL NG LP
Water heating capacity raised 40°C
MODEL 16 20 26
ML/M 10 12.5 16.25
Working pressure
Max 1200kPa
Gas injectors of the following size in mm
MODEL NG LPG MODEL NG LPG
are fitted for the approved gas types
16/20 1.35 1.35 mm 26
1.34 1.0mm
1.65 1.65 mm
1.65 1.2 mm
Input voltage single phase 50Hz
240V
Maximum output current
MODEL 16 20 26
Amp0.37 0.45 0.47
SAIG Approval certificate no.
MODEL 16/20 GSCS 20021
26 GSCS 20021
Inlet gas connection male thread
18mm
Cold water connection male thread
MODEL 16/20 13mm
26 18mm
Hot water connection male thread
MODEL 16/20 13mm
26 18mm
Relief valve pressure setting
14001cPa
Weight dry
MODEL 16/20 16kg
26 17kg
1.2 DATA PLATE
Left outside of cabinet
1.3 GAS TYPE
The temporary gas label is located on the cabinet top.
The label is the gas that this appliance is designed to operate with.
16
20
26
.40
.40
.56
.61
.68
.70
DO NOT OPERATE WITH ANY OTHER GAS TYPE.
TECHNICAL DATA
4
![](/html/55/555c/555ce2a2e4ffe3fe665ae5dec584d94bb8ced1d6dd807b84940471484ccc62e0/bg7.png)
1.4
HEATER DIMENSIONS:
DEPTH
165mm
WIDTH 350mm
HEIGHT
575mm
1.5
WARNING LABELS
Located on the side of the cabinet.
PLEASE READ THESE LABELS CAREFULLY.
1.6
INSTALLATION POSITION
THIS HEATER IS APPROVED FOR OUTDOOR INSTALLATION
ONLY-IT IS NOT SUITABLE FOR INDOOR USE.
Refer AS5601 for clearance details for flue terminal.
In addition,ensure that the appliance installation position permits easy access for
maintenance and operation.
For further infomation,please refer to the Gas Fitting Regulations.
1.7 POSITION FOR INSTALLATION
The heater must be installed by using a fixing method sufficient to hold the weight of
the unit (see the technical sheet for dimensions of mounting brackets and positions).
TECHNICAL DATA
5
![](/html/55/555c/555ce2a2e4ffe3fe665ae5dec584d94bb8ced1d6dd807b84940471484ccc62e0/bg8.png)
1.8 GAS CONNECTION
(1)
Fit a union to the water heater gas inlet for easy connection and removal. The thread
diameter is 18mm.
THIS DOES NOT INDICATE THE SIZE OF THE GAS SUPPLY
refer to AS5601
for
guidance on pipe sizing.
(2)
Fit an AGA approved isolating gas cock in the supply line adjacent to the water heater gas
connection.
(3)
Ensure that the supply pipe and the gas pressure regulator(LPG or NaturalGas) has
sufficient flow capacity for this and other appliances connected to the fitting line.
(4)
For LPG appliances ensure that gas cylinders are of sufficient size.The water heater alone
will require a regulator of 4KG per hour capacity.
(5)
Before connecting the appliance to the gas service purge any debris or air from the gas
service. Venting of purged gas shall be an area free of sources of ignition.
Close the isolating gas cock prior to connection of the appliance.
(6)
After connection check all joints for leaks with an approved leak tester.
Refer to
AS5601
Installation Code for pipe sizing details. For your assistance we have
included the following pipe sizing from
AS5601
for copper tube using Natural Gas.
NOMINAL PIPE
SIZE IN mm
STRAIGHT LENGTH OF
PIPE METRES
HOURLY RATE
IN MJ/h
13
4
43.0
18
4
82.2
20
4
142.0
25
4
313.0
THE ETERNITY 16/20/26 REQUIRES A MINIMUM OF 125/160/200 MJ/h FOR
THE CUSTOMER TO OBTAIN THE FULL PERFORMANCE BENEFIT.
SERVICE CALLS ARE CHARGEABLE FOR
UNITS WITH INCORRECT GAS PIPE SIZES.
GAS CONNECTION
6
![](/html/55/555c/555ce2a2e4ffe3fe665ae5dec584d94bb8ced1d6dd807b84940471484ccc62e0/bg9.png)
COLD WATER CONNECTION
1.9 COLD WATER SUPPLY TO WATER HEATER
Refer to the Technical Sheet for the position of connections. Minimum of 13mm for model
16/20 and 18mm for model 26 copper tube should be connected to the appliance . The
WATER INLET connection are 13mm BSP for model 16/20 and 18mm BSP for model
26 and requires a union to allow for removal of the water heater. Pipe sizing from the
cold water supply should be sized according to local BY LAWS for water supply.
ISOLATING GATE VALVE or BALL VALVE
A GATE VALVE or BALL VALVE must be used on the cold water inlet to the water
heater. THIS REQUIREMENT IS AN AUSTRALIA WIDE REQUIREMENT UNDER
THE NATIONAL PLUMBING CODE.
IF THE ABOVE INSTRUCTION IS NOT CARRIED OUT ALL WARRANTIES ON THE
UNIT WILL BE VOIDED.
STOP TAPS OR COMBINATION STOP TAPS AND
NON-RETURN VALVES ARE NOT TO BE USED!
N.B. NO PRESSURE REDUCTION VALVE IS
REQUIRED UNLESS THE INLET WATER
PRESSURE EXCEEDS 1400kPa AT ANY TIME
OF THE DAY. EG
EARLY HOURS OF THE
MORNING.