Introduction:
Thank you for your purchase of the Premier150™ Spot. When unpacking and before disposing of
the carton, check there is no transportation damage before using the projector. Should there be
any damage caused by transportation, consult your dealer and do not use the apparatus.
Premier150 Spot Eternal Lighting Fe b 2016
![](/html/1c/1c64/1c64c33dbb26638f2536220d41d3b16dc028bb92ec353c873ce32890d4ccfb7c/bg2.png)
Safety Measures:
The projector is for indoor use only, IP20. Use only in dry locations. Keep this device away from rain
and moisture, excessive heat, humidity and dust. Do not allow contact with water or any other
liquids.
DO NOT mount the projector directly onto an inflammable surface
The projector is only intended for installation, operation and maintenance by qualified personnel.
The projector must be installed in a location with adequate ventilation, at least 20 inches fro m
adjacent wall surfaces. Be sure that no ventilation slots are blocked.
Do not project the beam onto in ammable surfaces, minimum dis 5 inches.
Avoid direct exposure to the light from the lamp. The light is harmful to the eye. Do not attempt to
dismantle and/or modify the projector in any way.
Electrical connection must only be carried out by quali ed personnel.
Before installation, ensure that the voltage and frequency of power supply match the power
requirements of the projector. It is essential that each projector is correctly earthed and that
electrical installation conforms to all relevant standards. Do not connect this device to any
other types of dimmer apparatus.
Make sure that the power-cord is never crimped or damaged by sharp edges. Never let the powercord come into contact with other cables. Only handle the power-cord by the plug. Never pull out
the plug by tugging the power-cord.
Keep a projector’s optical system clean. Do not touch LED lens with bare hands.
The projector should always be installed with a secondary safety cord.
Shields and lens shall be changed if they have become visibly damaged to such an extent than
their effectiveness is impaired, for example by cracks or deep scratches.
LED lamps should be replaced if damaged or having reached life limit.
Exterior surface temperatures of the luminaire after 5 minutes operation is 55C°, when steady
state is achieved 70C°.
There is no user serviceable parts inside the projector do not open the housing and never operate
the projector with the covers removed.
If you have any questions, don’t hesitate to consult your dealer or manufacturer.
Features:
• RGBW 150 Watt LED
• Output Lux @ 1m 40700 and @ 2m 12300+ (Comparable to 575 Watt Bulb)
• Light Source: 150 Watt RGBW LED - 60,000 Hour LED Engine Life
• Drive current 2.25 Amp
• Electrical Input Voltage 90 ~ 240V AC 50-60Hz
• Power Consumption 125W max at full output
Premier150 Spot Eternal Lighting Fe b 2016
![](/html/1c/1c64/1c64c33dbb26638f2536220d41d3b16dc028bb92ec353c873ce32890d4ccfb7c/bg3.png)
• Control Protocol / DMX512 On-board Display for Auto and Sound Active Control & Master/Slave
Functions
• DMX Modes (16CH, 18CH and 24CH Modes)
• Optical System Focus Electronic DMX Focus
• Dimmer 0-100% 8-Bit in 16CH and 18CH or 16-Bit in 24 CH
• Strobe Variable speed Mechanical (1Hz ~ 13Hz)
• Prism Rotating 3-facet prism
• Movement Pan 540° Tilt 270°
• Pan/tilt resolution 8-16 bit
• Special Pan/Tilt Movement Blackout
• User-selectable pan/tilt ranges
• 2 Gobo Wheels
(One Fixed Gobo Wheel: 7 gobos +Open
(One Rotating Gobo Where 7 Gobos Metal and Glass +Open)
• Gobo-flow effect
• Gobo shake
• Gobo Morphing
• Bi-directional rotation
• Millions of Colors because No Color Where - Smooth color mixing
• Rainbow-flow effect
• Physical Dimensions Base 17 3/4" x 17" / Base to Head Up 17"
• Weight 29.8 lbs
• Housing Flame-retardant heavy duty plastic
• Case Color Black
• 3Pin DMX in and out
• Powercon Power Input
• DMX in/out
• Cooling Forced Convection
• Max. Ambient TEMP 113° F (45°C)
Power Supply
Connect the power cord as follows:
L (live) =brown
E (earth) =yellow/green
N (neutral) =blue
Use the plug provided to connect the main power to the projector paying attention to the voltage and
frequency marked on the panel of the projector. It is recommended that each projector be supplied
separately so that they may be individually switched on and off.
IMPORTANT
It is essential that each projector is correctly earthed and the electrical installation conforms to
all relevant standards.
Control Connection
Premier150 Spot Eternal Lighting Fe b 2016
![](/html/1c/1c64/1c64c33dbb26638f2536220d41d3b16dc028bb92ec353c873ce32890d4ccfb7c/bg4.png)
DMX OUT DMX IN
1
2
1
2
3
4
5
FUNCTION
GND
DATA-
FUNCTION
GND
DATADATA+
N/C
N/C
2 1
3 PIN
DMX OUT DMX IN
5
5 PIN
4 2 2 4
3 3
1 5
PI N
PI N
Connection between controller and projector and between one projector and another must be made
with a 2 core-screened cable, with each core having at least a 0.5mm diameter.
Connection to and from the projector is via cannon 5 pin (which are included with the projector) or 3
pin XLR plugs and sockets. The XLR's are connected as shown in the figure above.
Note: care should be taken to ensure that none of the pins touch the metallic body of the plug or each
other. The body of the plug is not connected in any way. The projector accepts digital control signals in
protocol DMX512 (1990).
Connect the controller’s output to the first fixture’s input, and connect the first fixture’s output to the
second fixture’s input and connect the rest fixtures in the same way. Eventually connect the last
fixture’s output to a DMX terminator as shown in the figure below.
D M X Termi n a tor
In the Controller mode, at the last fixture in the chain, the DMX output has to be connected with a
DMX terminator. This prevents electrical noise from disturbing and corrupting the DMX control
signals.
The DMX terminator is simply an XLR connector with a 120 Ω(ohm) resistor connected across pins
2 and 3, which is then plugged into the output socket on the last projector in the chain.
Setup O p tio ns
The Pre mier 15 0 Spo t c o nfi gura t ion ca n be se t co nve niently b y press ing the but to ns on t h e LC D
d isplay. T o b ro wse or cha nge the se tup opt ions , pre ss EN TER to unlo ck the pa ne l. Me nu wi ll be
d isplayed on the scre e n; each menu ha s its o wn sub-menu. Eac h menu ha s sp ec ific func tio n, re fer to
“Ope r atio n Menu ” for det a ls.
Premier150 Spot Eternal Lighting Fe b 2016