Eternal Lighting Cube RGBA User Manual

CUBE RGBA
User Manual
Battery Powered Wireless DMX LED Fixture
Or
Battery Powered LED Fixture – (Without DMX Built inside)
2
Please read over this manual before operating the light
Most important: FIRST CHARGE THE FIXTURES FOR 6-8 Hours on the First Charge before
use. Plug in Power cord. Turn off Power Switch and Turn other switch to charge.
Introduction
Unpacking: Thank you for purchasing the CUBE™ RGBA. Every CUBE™ RGBA has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your fixture for any damage and be sure all accessories necessary to operate the unit has arrived intact. In the case damage has been found or parts are missing, please contact the manufacturer or your dealer for further instructions. Do not return this unit to your dealer without first contacting.
Introduction: The CUBE™ RGBA is a DMX intelligent and battery powered LED par light. This par light is light weight and compact which makes it a great piece for mobile DJ‟s and clubs.
Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.
Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs yourself; doing so will void your manufactures warranty. In the unlikely event your unit may require service please contact the manufacturer or your dealer.
PLEASE recycle the shipping carton whenever possible. General Instructions
To optimize the performance of this product, please read these operating instructions carefully to familiarize you with the basic operations of this unit. These instructions contain important safety information regarding the use and maintenance of this unit. Please keep this manual with the unit, for future reference.
Features
Multi-colors  Control Channels:4/8CH  Color Strobe  Master/Slave synchronization  DMX-512 protocol  Electronic Dimming 0-100%  Operating Modes: Sound activation, Auto and DMX control mode  Led operation menu with function buttons  Daisy Chain Units Together in DMX Mode  1-20 flashes/sec strobe effect
3
Safety Precautions
To reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.
Do not spill water or other liquids into or on to your unit.
Be sure that the local power outlet matches that of the required voltage for your unit.
Do not attempt to operate this unit if the power cord has been frayed or broken. Do not
attempt to remove or break off the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and fire in case of an internal short.
Disconnect from main power before making any type of connection.
Do not remove the cover under any conditions. There are no user serviceable parts inside.
Never operate this unit when its cover is removed.
Never plug this unit in to a dimmer pack.
Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6”
(15cm) between this device and a wall.
Do not attempt to operate this unit, if it becomes damaged.
This unit is intended for indoor use only; use of this product outdoors voids all warranties.
During long periods of non-use, disconnect the unit‟s main power.
Always mount this unit in safe and stable matter.
Power-supply cords should be routed so that they are not likely to be walked on or pinched by
items placed upon or against them, paying particular attention to the point they exit from the unit.
Cleaning -The fixture should be cleaned only as recommended by the manufacturer. See “Cleaning” for details.
Heat -The appliance should be situated away from heat sources such as radiators, heat
registers, stoves, or other appliances (including amplifiers) that produce heat.
The fixture should be serviced by qualified service personnel when:
A. The power-supply cord or the plug has been damaged. B. Objects have fallen, or liquid has been spilled into the appliance. C. The appliance has been exposed to rain or water. D. The appliance does not appear to operate normally or exhibits a marked change in
performance
Fuse standard is2A/250V
Grounded using yellow/green line
The ambient temperature must always be under +35° C
Set Up Power Supply: Before plugging your unit in, be sure the source voltage in your area matches
the required voltage for your CUBE™ RGBA. The CUBE™ RGBA is workable in 100-220V/50~60Hz. Because line voltage may vary from venue to venue, you should be sure your unit voltage matches the wall outlet voltage before attempting to operate you fixture.
Operating Instructions
Operating Modes: You can use the CUBE™ RGBA in 5 ways:
Sound activation – The unit will activated by the sound signal.  Static display – The unit will display the color in static way.
4
Auto Mode - The unit will automatically chase through the different patterns.  DMX control mode - This function will allow you to control the lighting with a standard DMX
512 controller.
Battery powered This function will allow you to control the lighting independently without
any DMX cable
DMX Mode: Operating through a DMX controller give the user the freedom to create their own programs tailored to their own individual needs. This function also allows you to use your fixtures as pattern changing lights.
1. This function will allow you to control each individual fixture‟s traits with a standard DMX 512
controller.
2. The CUBE™ RGBA uses 6 DMX channels to operate. Please see “DMX Values and
Functions” for the DMX traits.
3. To run your fixture in DMX mode, plug in the fixture via the XLR connections to any standard
DMX controller. Set your desired DMX address following the setup specifications that come with your DMX controller.
4. The unit can automatically recognize the DMX signal once the DMX connection is done.
DMX Linking: To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.
DMX Values and Functions 4CH Mode
8CH Mode
Value
RGBA 10mm 198
CH1
0-255
RED dimmer (0-255)
CH2
0-255
GREEN dimmer (0-255)
CH3
0-255
BLUE dimmer (0-255)
CH4
0-255
AMBER dimmer (0-255)
CH5
0-255
R, G, B, A dimmer (0-255)
CH6
0-255
Auto Slow to Fast (0-255)
Value
RGBA 10mm 198
CH1
0-255
RED dimmer (0-255)
CH2
0-255
GREEN dimmer (0-255)
CH3
0-255
BLUE dimmer (0-255)
CH4
0-255
AMBER dimmer (0-255)
Loading...