Eterna Lighting PIRHL60BK Installation Instructions

874/2012
MODELNO.
PIRHL60 Range
SPECIFICATIONS:
• Detection range: Approx. 120° (horizontal), Max. 12 metres.
• Duration time: from 3 min ± 20 sec.
• Factory preset PIR - no override facilit y.
CLEANING:
To avoid dust build-up and ensure proper functioning of the half lantern light, please wipe the sensor lens lightly with a damp cloth every 3 months.
Disconnec t the power and clean the exterior only of this tting with a moist (not wet) cloth.
Do not use any chemical or abrasive cleaners.
EVENTUALLY, YOU MAY WANT TO REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from Electrical and Electronic Equipment (European “WEEE Directive” eective August 2005—UK WEEE Regulations eective 2nd January 2007). Environment Agency Registered Producer: WEE/ GA0248QZ.
WHEN YOUR PRODUC T COMES TO THE END OF ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE RECYCLE IT WHERE FACILITIES EXIST  DO NOT DISPOSE WITH HOUSEHOLD WASTE.
INSTALLATION INSTRUCTIONS
A guide for qualied electricians
LAMP REPLACEMENT:
• Switch o the electricity at the mains.
• Release front diuser cover with screwdriver.
• Remove and replace lamp making sure it seats correctly in the lampholder.
• Replace front diuser cover.
• Restore power.
REPLACEMENT LAMP TYPE:
Requires 1 x suitable ES energy saving lamp (not included).
Fitting is rated at 60W max.
Issue 2013
FOR PRODUCT ADVICE:
• T: 01933 673 144
• F: 01933 678 083
• E: sales@eterna-lighting.co.uk
IF YOU EXPERIENCE PROBLEMS:
If you believe your product is defective, please return it to the place where you bought it. Our Technical Team will gladly advise on any Eterna Lighting product, but may not be able to give specic instructions regarding individual installations.
Visit our website:
www.eterna-lighting.co.uk
Pack contents:
Model:
• Mounting xtures
PIRHL60BK / PIRHL60WH
Half Lantern with 120° PIR
These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE USING YOUR NEW FITTING
PLEASE RETAIN FOR FUTURE REFERENCE
INTRODUCTION:
L
Brown (power cable)
Rubber Grommet
Plastic Cover
Blue (power cable)
N
Fixing Wall Screw
1.8-2.5M
4M 8M 12M
120˚
Appr.
PIR Sensor
L
Brown (power cable)
Rubber Grommet
Plastic Cover
Lamp Holder
Fixing Wall Screw
Blue (power cable)
N
Fixing Wall Screw
Front Housing
L
Brown (power cable)
Rubber Grommet
Plastic Cover
Lamp Holder
Fixing Wall Screw
Blue (power cable)
N
The half lantern incorporates a PIR (passive Infrared) sensing device which continuously scans a preset operating zone and immediately switches the light on when it detects movement in that area.
This means that whenever movement is detected within the range of the sensor the light will switch on automatically to illuminate the area you have selected to light. While there is movement within range of the unit the light will remain on.
READ THIS FIRST:
Check the pack and make sure you have all of the parts listed on the front of this booklet. If not, contact the outlet where you bought this product.
This product must be installed by a competent person in accordance with the current building and IEE wiring regulations.
As the buyer, installer and/or user of this product it is your own responsibility to ensure that this t ting is t for the purpose for which you have intended it. Eterna lighting cannot accept any liability for loss, damage or premature failure resulting from inappropriate use.
This product is designed and constructed according to the principles of the appropriate British Standard and is intended for normal domestic ser vice. Using this tting in any other environments may result in a shortened working life.
Switch o the mains before commencing installation and remove the appropriate circuit fuse or lock o MCB.
This unit is suitable for outdoor use.
This product is designed for permanent connection to xed wiring: this must be a suitable circuit (protected with the appropriate MCB or fuse).
Before making xing hole(s), check that there are no obstructions hidden beneath the mounting surface such as pipes or cables.
Make sure that the xings are strong enough to support the considerable weight of the tting and hold it rigidly.
The lamp must be positioned so that there is at least
0.5m (500mm) between the bulb and any illuminated surface.
When making connections ensure that the terminals are tightened securely and that no strands of wire protrude. Check that the terminals are tightened onto the bared conductors and not onto any insulation.
WARNING: This prodct becomes hot!
This product is not intended to be used by children and persons with sensory, physical and/or mental impairments that would prevent them from using it saf ely.
IMPORTANT - Always switch o the mains power before changing the lamp.
You are advised at every stage of your installation to double-check any electrical connections you have made. After you have completed your installation there are electrical tests that should be carried out, these tests are specied in the current IEE wiring and building regulations.
This product is double insulated, do not connect any part to ear th.
WHERE TO FIT YOUR PIR HALF LANTERN:
To achieve best results we suggest you take the following points into consideration:
Do not mount on a surface that has vibration.
Ideally the PIR half lantern should be mounted 1.8 to 2.5 metres (6 to 8ft) above the area to be scanned (refer to Fig. 1 below).
Fig 1
120˚
1.8-2.5M
To avoid damage to the unit do not aim sensor towards the sun.
Avoid positioning the sensor unit adjacent to a bright light source which may prevent the unit from operating when the lux control is set to operate in dark conditions.
Avoid nuisance false triggering by directing sensor away from:
Trees and shrubs Reective surfaces such as smooth white walls Swimming pools Heat sources such as boiler ues
The PIR sensor scanning specications (approximately 12 metres at 120°) may vary slightly depending on the mounting height and location.
4M 8M 12M
Appr.
The detection range of the unit may also alter with temperature change. Before selecting a place to install your PIR lantern you should note that movement across the scan area is more eective than movement directly towards or away from the sensor (refer to Fig. 2 below).
If movement is made walking directly towards or away from the sensor and not across the apparent detection range will be substantially reduced (refer to Fig. 3 below).
Fig 2 Fig 3
EFFECTIVE
LESS EFFECTIVE
Fig 4
Front Housing
PIR Sensor
INSTALLATION:
Please refer to Fig. 4 below.
1) Remove the two screws at the top and bot tom of the tting and lift o the front housing.
2) Position the tting on the sur face where it is to be installed and mark the mounting hole positions.
3) Drill and plug the wall at the marked positions ensuring you pass the cable wire through rubber grommet.
4) Screw and x the back housing to wall with suitable mounting screws (supplied).
5) Remove PIR terminal cover and expose the connector block and make connections according to the relatives symbols:
(L) Brown wire (N) Blue wire.
Make sure that terminals are tightened securely and that no strands of wire protrude.
6) Replace and secure the plastic PIR cover.
7) Insert suitable ES energy saving lamp.
8) Replace the front housing and tighten the screws.
9) Restore the power and switch on.
Fixing Wall Screw
Lamp Holder
Plastic Cover
Rubber Grommet
Brown
L
(power cable)
Blue
N
(power cable)