Eterna Lighting LDLEM3 Installation Instructions

EVENTUALLY, YOU MAY WANT TO REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from Electrical and Electronic Equipment (European “WEEE Directive” eective August 2005—UK WEEE Regulations eec tive 2nd January 2007). Environment Agency Registered Producer: WEE/GA0248QZ.
WHEN YOUR PRODUCT COMES TO THE END OF IT S LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE RECYCLE IT WHER E FACILITIES EXIST  DO N OT DISPOSE WITH HOUSEHOLD WASTE.
INDUSTRIAL BATTERIES:
Within cer tain products Eterna Lighting Ltd places lead acid, lithium ion, nickel cadmium & nickel metal hydride batteries on the market. Industrial batteries are subject to waste regulation under the Waste Batteries and Accumulators Regulations 2009 and should be disposed of responsibly. Purchasers may be able to dispose of their waste industrial batteries locally via legitimate licensed trade waste contractors. Eterna is obliged to take back, free of charge and within a reasonable time, waste industrial batteries of the same chemistry supplied to a Purchaser, for treatment and recycling and is required to do this in any calendar year new industrial batteries are placed on the market. In certain circumstances, this may include batteries not originally supplied by Eterna. If any Purchaser requires Eterna to take back Industrial batteries, they should write to the Operations Director, Eterna Lighting Ltd, Huxley Close, NN8 6AB, who will then advise on the necessary arrangements for the receipt, proper treatment and recycling of, the waste industrial batteries.
LAMP REPLACEMENT:
The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced.
BATTERY REPLACEMENT:
If after routine operation check, the lamp does not remain lit for the three hour period, a new batter y pack may be required.
1) Switch o the electricity at the mains and allow batteries to fully discharge then reconnect to supply and allow charging for 24 hours.
2) Test again for 3 hours, if light does not remain lit, then change the batter y pack as follows:
3) Isolate from mains supply and unplug the battery plug lead from the socket and re-plug the new bat tery.
4) Restore power and allow charging for 24 hours.
5) Perform full operation check and update test record.
REPLACEMENT BATTERY TYPE:
3.6V 2000mAh Ni-Cad - 3 x C Cell.
CLEANING:
Clean this t ting only with a soft dry cloth.
Do not use any chemical or abrasive cleaners.
IF YOU EXPERIENCE PROBLEMS:
If you believe your product is defective, please return it to the place where you bought it. Our Technical Team will gladly advise on any Eterna Lighting product, but may not be able to give specic instructions regarding individual installations.
INSTALLATION INSTRUCTIONS
A guide for qualied electricians
Email: sales@eterna-lighting.co.uk / technical@eterna-lighting.co.uk
Visit our website: www.eterna-lighting.co.uk
Pack contents:
inverter and battery pack
Model:
1 x Silver trim 1 x White trim 1 x Maintenance check record
LDLEM3
LED Emergency Downlight
These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION
AND RETAIN FOR FUTURE REFERENCE
Made in ChinaIssue 1116
READ THIS FIRST:
Check the pack and make sure you have all of the parts listed on the front of this booklet. If not, contact the outlet where you bought this product.
As the buyer, installer and/or user of this product it is your own responsibility to ensure that this tting is t for the purpose for which you have intended it. Eterna Lighting cannot accept any liability for loss, damage or premature failure resulting from inappropriate use.
Switch o the mains before commencing installation and remove the appropriate circuit fuse or lock o MCB.
Use only with the driver/inverter provided. Do not connect directly to the mains.
This unit is suitable for indoor use only.
This product is designed for permanent connection to xed wiring: this must be a suitable circuit (protected with the appropriate MCB or fuse).
Do not cover the t ting, bat tery and driver with any insulating materials.
The driver should be placed where it cannot come into contact with water or moisture.
You are advised at every stage of your installation to double-check any electrical connections you have made. After you have completed your installation there are electrical tests that should be carried out, these tests are specied in the current IEE wiring and building regulations.
The batteries supplied with this tting are a consumable part and therefore may be outside of any warranty oered.
INSTALLATION:
Choose the location for the new tting taking the above points into consideration.
1) Mark the locations of your downlight and then using an appropriate hole cutter, make a 32mm diameter hole. (See below).
2) Prepare the route for the mains cable and feed through the hole and make the connections to the input side of the driver/inverter.
3) Write commissioning date on to battery.
4) Feed the driver/inverter through the hole, followed by the batter y pack, which can lay adjacent to the hole.
5) Feed the excess cable through the hole and press the down light into position (see below) until it is retained by the springs. The tting may require some manipulation in order to pass through the hole. Do not enlarge the hole to make tting easier.
6) Restore the power and check tting is working correctly. The LED will illuminate green on normal operation, which indicates the tting is charging. On mains power failure the LED will illuminate white light continuously for a minimum of 3 hour
SPECIFICATION:
EBLF: 0.92
OPERATION CHECKS:
Periodic testing should be carried out to ensure emergency lighting is operating correctly. Interruption of the supply, causing the tting to be energised from the battery, should be carried out by the operation of a local keyswitch or other isolation device. During this period all ttings should be examined visually to ensure that they are functioning correctly. At the end of the test period the supply shall be restored and all indicator lamps or devices checked to ensure that the normal supply has been restored.
DA ILY:
Visual inspection of the batter y charge LED.
EACH MONTH:
Isolate the power supply for a period sucient to ensure that each lamp is illuminated. Endorse the test record form supplied.
ONCE EACH YEAR:
Isolate the power supply and check that the light is still illuminated af ter 3 hours. Endorse the test record form.
Because of the possibility of a failure of the normal lighting supply occurring shortly after a period of testing of the emergency lighting system or during the subsequent recharge period, all full duration tests shall wherever possible be undertaken preceding time of low risk to allow for battery recharge.
NOTE: please keep this instruction booklet and the test record in a safe place. A re ocer or other authorised person may want to see your record of inspection and testing.
INPUT 220-240VAC
L E N
NEUTRAL
EARTH
LIVE
50/60Hz
DRIVER
BATTERY
1.4W LED
Dia = 32mm
Ceiling
Clips will lock
fitting into place
Ceiling