LED LAMP SPECIFICATIONS:
Luminaire lumens (with
diuser)
Lumens from chip (no
diuser)
Useful lumens
Rated Wattage 12W
Rated luminous ux 1150 lm
Nominal life time of the lamp 35,000 hrs
Colour temperature 4200K
Number of switching cycles
before premature lamp
failure
Warm-up time up to 60% of
the full light output
Dimmable No
Nominal beam angle 120°
Rated power 12W
Rated lamp lifetime 35,000 hrs
Lamp power factor >0.9
Lumen maintenance factor at
end of nominal life
Starting time <0.1s
Colour rendering ≥80
Colour consistency
Rated peak intensity 280cd
Rated beam angle 120°
Voltage / Frequency 240V~50-60Hz
Not suitable for accent lighting
1200 lm
1450 lm
1150 lm
≥15,000
<1s
≥0.70
Within a six step
Macadam ellipse
Eterna
Ligh�ng
LTD
12 kWh / 1000h
000 kWh/1000h
CO12SCPC
CODE HERE
A
A
INSTALLATION INSTRUCTIONS
A guide for qualied electricians
++
Pack contents:
1 x LED ceiling tting
Model:
Email: sales@eterna-lighting.co.uk / technical@eterna-lighting.co.uk
Visit our website: www.eterna-lighting.co.uk
CO12SCPC
12W IP65 LED Circular Ceiling/Wall Light With Photocell
These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION
AND RETAIN FOR FUTURE REFERENCE
Made in ChinaIssue 0121

READ THIS FIRST:
Check the pack and make sure you have all of the
parts listed on the front of this booklet. If not,
contact the outlet where you bought this product.
This product must be installed by a competent
person in accordance with the current building and
IEE wiring regulations.
As the buyer, installer and/or user of this product it
is your own responsibility to ensure that this tting
is t for the purpose for which you have intended
it. Eterna Lighting cannot accept any liabilit y for
loss, damage or premature failure resulting from
inappropriate use.
This product is designed and constructed according
to the principles of the appropriate British Standard
and is intended for normal domestic service. Using
this tting in any other environments may result in
a shortened working life, for example where there
is prolonged periods of use or higher than normal
ambient temperatures such as lighting public or
shared spaces or in nursing /care home facilities.
Switch o the mains before commencing installation
and remove the appropriate circuit fuse or lock o
MCB.
This product is suitable for use in living areas, and
Bathroom Zone 2 and outsides of zones.
If being tted in a bathroom a 30mA RCD must
be used.
Bathroom Zones Diagram
ZONE 2
ZONE 2
60cm
radius
from tap
60cm240cm
This product is designed for permanent connec tion
to xed wiring: this must be a suitable circuit
(protected with the appropriate MCB or fuse).
This product is suitable for installation on surfaces
with normal ammability e.g. wood, plasterboard
and masonry. It is not suitable for use on highly
ammable sur faces (e.g. polystyrene, textiles).
Before making xing hole(s), check that there are no
obstructions hidden beneath the mounting surface
such as pipes or cables.
ZONE 1
ZONE 0
The chosen location of your new tting should
allow for the product to be securely mounted (e.g.
to a ceiling joist) and safely connected to the mains
supply (lighting circuit).
When making connections ensure that the terminals
are tightened securely and that no strands of wire
protrude. Check that the terminals are tightened
onto the bared conductors and not onto any
insulation.
This product is double insulated, do not connect any
part to Earth.
This product is not intended to be used by children
and persons with sensory, physical and/or mental
impairments that would prevent them from using it
saf ely.
You are advised at every stage of your installation to
double-check any electrical connections you have
made. After you have completed your installation
there are electrical tests that should be carried out,
these tests are specied in the current IEE wiring and
building regulations.
LAMP REPLACEMENT:
The light source is designed to last the lifetime of the
luminaire.
The light source contained in this luminaire
shall only be replaced by the manufacturer,
service agent or a similar qualied person.
CAUTION, RISK OF ELECTRIC SHOCK.
PHOTOCELL:
Do not install under eaves or in a location of frequent
225cm
shadow that will prevent the light from switching o
when required. Do not install near other sources of
bright light that will prevent the light from switching
on when the ambient light level falls.
Do not install on white or ver y reective surfaces as
this may cause the photocell to work incorrectly due
to light reec ting back in to the photocell.
INSTALLATION:
Choose the location for your new tting according to
the conditions listed opposite.
01) Remove diuser.
02) Unscrew the gear tray screw and allow the gear
tray to rest on its hinge.
03) Drill holes in the back of your tting for your
xing screws, take care and drill gently to
ensure a clean hole through. Use a drill bit sized
appropriately to your xing screws (not supplied).
04) Using the back of your tting as a template,
mark the position of your xing holes on your
mounting sur face.
05) Prepare the holes in your mounting surface as
appropriate for your xings.
06) Pierce the rubber grommet in the back of your
tting making a hole just large enough to make a
tight t around the incoming mains cable.
07) Thread the cable through the grommet and oer
the tting to the ceiling / wall.
08) Secure the tting in place. Note, if protection
against ingress of moisture is required, the heads
of screws must be covered with a silicone or
similar sealant.
09) Check that the grommet is still correctly tted in
the cable entry hole and around the incoming
cable.
10) Make the electrical connections to the terminal
block according to the markings:
Brown to live (L)
Blue to neutral (N)
11) Replace gear tray and secure in position.
12) Replace diuser.
13) Restore the power and switch on.
14) The tting will light when the power has been
restored and the ambient light level falls below
the preset threshold on the photocell (NOTE: this
unit is not adjustable).
On: 10-20lux • O: 30-60lux
EVENTUALLY, YOU MAY WANT TO
REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from
Electrical and Electronic Equipment (European
“WEEE Directive” eective August 2005—UK
WEEE Regulations eective 2nd January 2007).
Environment Agency Registered Producer: WEE/
GA0248QZ.
WHEN YOUR PRODUCT COMES TO THE END OF
ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE
RECYCLE IT WHERE FACILITIES EXIST DO NOT
DISPOSE WITH HOUSEHOLD WASTE.
CLEANING:
Clean this tting only with a soft dry cloth.
Do not use any chemical or abrasive cleaners.
IF YOU EXPERIENCE PROBLEMS:
If you believe your product is defective, please return
it to the place where you bought it. Our Technical
Team will gladly advise on any Eterna Lighting
product, but may not be able to give specic
instructions regarding individual installations.
Brown
(Power Cable)
Blue
(Power Cable)
L N
Brown
(Power Cable)
Blue
(Power Cable)