Eterna Lighting CO12SCPC Installation Instructions

LED LAMP SPECIFICATIONS:
Luminaire lumens (with diuser)
Lumens from chip (no diuser)
Useful lumens
Rated Wattage 12W
Rated luminous ux 1150 lm
Nominal life time of the lamp 35,000 hrs
Colour temperature 4200K
Number of switching cycles before premature lamp failure
Warm-up time up to 60% of the full light output
Dimmable No
Nominal beam angle 120°
Rated power 12W
Rated lamp lifetime 35,000 hrs
Lamp power factor >0.9
Lumen maintenance factor at end of nominal life
Starting time <0.1s
Colour rendering ≥80
Colour consistency
Rated peak intensity 280cd
Rated beam angle 120°
Voltage / Frequency 240V~50-60Hz
Not suitable for accent lighting
1200 lm 1450 lm
1150 lm
≥15,000
<1s
≥0.70
Within a six step
Macadam ellipse
Eterna
Ligh�ng
LTD
12 kWh / 1000h
000 kWh/1000h
CO12SCPC
CODE HERE
A
A
INSTALLATION INSTRUCTIONS
A guide for qualied electricians
++
Pack contents: 1 x LED ceiling tting
Model:
Email: sales@eterna-lighting.co.uk / technical@eterna-lighting.co.uk
Visit our website: www.eterna-lighting.co.uk
CO12SCPC
12W IP65 LED Circular Ceiling/Wall Light With Photocell
These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION
AND RETAIN FOR FUTURE REFERENCE
Made in ChinaIssue 0121
READ THIS FIRST:
Check the pack and make sure you have all of the parts listed on the front of this booklet. If not, contact the outlet where you bought this product.
This product must be installed by a competent person in accordance with the current building and IEE wiring regulations.
As the buyer, installer and/or user of this product it is your own responsibility to ensure that this tting is t for the purpose for which you have intended it. Eterna Lighting cannot accept any liabilit y for loss, damage or premature failure resulting from inappropriate use.
This product is designed and constructed according to the principles of the appropriate British Standard and is intended for normal domestic service. Using this tting in any other environments may result in a shortened working life, for example where there is prolonged periods of use or higher than normal ambient temperatures such as lighting public or shared spaces or in nursing /care home facilities.
Switch o the mains before commencing installation and remove the appropriate circuit fuse or lock o MCB.
This product is suitable for use in living areas, and Bathroom Zone 2 and outsides of zones.
If being tted in a bathroom a 30mA RCD must be used.
Bathroom Zones Diagram
ZONE 2
ZONE 2
60cm radius from tap
60cm240cm
This product is designed for permanent connec tion to xed wiring: this must be a suitable circuit (protected with the appropriate MCB or fuse).
This product is suitable for installation on surfaces with normal ammability e.g. wood, plasterboard and masonry. It is not suitable for use on highly ammable sur faces (e.g. polystyrene, textiles).
Before making xing hole(s), check that there are no obstructions hidden beneath the mounting surface such as pipes or cables.
ZONE 1
ZONE 0
The chosen location of your new tting should allow for the product to be securely mounted (e.g. to a ceiling joist) and safely connected to the mains supply (lighting circuit).
When making connections ensure that the terminals are tightened securely and that no strands of wire protrude. Check that the terminals are tightened onto the bared conductors and not onto any insulation.
This product is double insulated, do not connect any part to Earth.
This product is not intended to be used by children and persons with sensory, physical and/or mental impairments that would prevent them from using it saf ely.
You are advised at every stage of your installation to double-check any electrical connections you have made. After you have completed your installation there are electrical tests that should be carried out, these tests are specied in the current IEE wiring and building regulations.
LAMP REPLACEMENT:
The light source is designed to last the lifetime of the luminaire.
The light source contained in this luminaire shall only be replaced by the manufacturer, service agent or a similar qualied person.
CAUTION, RISK OF ELECTRIC SHOCK.
PHOTOCELL:
Do not install under eaves or in a location of frequent
225cm
shadow that will prevent the light from switching o when required. Do not install near other sources of bright light that will prevent the light from switching on when the ambient light level falls.
Do not install on white or ver y reective surfaces as this may cause the photocell to work incorrectly due to light reec ting back in to the photocell.
INSTALLATION:
Choose the location for your new tting according to the conditions listed opposite.
01) Remove diuser.
02) Unscrew the gear tray screw and allow the gear tray to rest on its hinge.
03) Drill holes in the back of your tting for your xing screws, take care and drill gently to ensure a clean hole through. Use a drill bit sized appropriately to your xing screws (not supplied).
04) Using the back of your tting as a template, mark the position of your xing holes on your mounting sur face.
05) Prepare the holes in your mounting surface as appropriate for your xings.
06) Pierce the rubber grommet in the back of your tting making a hole just large enough to make a tight t around the incoming mains cable.
07) Thread the cable through the grommet and oer the tting to the ceiling / wall.
08) Secure the tting in place. Note, if protection against ingress of moisture is required, the heads of screws must be covered with a silicone or similar sealant.
09) Check that the grommet is still correctly tted in the cable entry hole and around the incoming cable.
10) Make the electrical connections to the terminal block according to the markings:
Brown to live (L) Blue to neutral (N)
11) Replace gear tray and secure in position.
12) Replace diuser.
13) Restore the power and switch on.
14) The tting will light when the power has been restored and the ambient light level falls below the preset threshold on the photocell (NOTE: this unit is not adjustable).
On: 10-20lux • O: 30-60lux
EVENTUALLY, YOU MAY WANT TO REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from Electrical and Electronic Equipment (European “WEEE Directive” eective August 2005—UK WEEE Regulations eective 2nd January 2007). Environment Agency Registered Producer: WEE/ GA0248QZ.
WHEN YOUR PRODUCT COMES TO THE END OF ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE RECYCLE IT WHERE FACILITIES EXIST  DO NOT DISPOSE WITH HOUSEHOLD WASTE.
CLEANING:
Clean this tting only with a soft dry cloth.
Do not use any chemical or abrasive cleaners.
IF YOU EXPERIENCE PROBLEMS:
If you believe your product is defective, please return it to the place where you bought it. Our Technical Team will gladly advise on any Eterna Lighting product, but may not be able to give specic instructions regarding individual installations.
Brown (Power Cable)
Blue (Power Cable)
L N
Brown (Power Cable)
Blue (Power Cable)
Loading...