READ THIS FIRST:
Check the pack and make sure you have all of the
parts listed on the front of this booklet. If not,
contact the outlet where you bought this product.
This product contains glass, care must be taken when
assembling, tting or handling to prevent personal
injury or damage to the product.
This product must be installed by a competent
person in accordance with the current building and
IEE wiring regulations.
As the buyer, installer and/or user of this product it
is your own responsibility to ensure that this tting
is t for the purpose for which you have intended
it. Eterna Lighting cannot accept any liability for
loss, damage or premature failure resulting from
inappropriate use.
This product is designed and constructed according
to the principles of the appropriate British Standard
and is intended for normal domestic service. Using
this tting in any other environments may result in
a shortened working life, for example where there
is prolonged periods of use or higher than normal
ambient temperatures such as lighting public or
shared spaces or in nursing /care home facilities.
Switch o the mains before commencing installation
and remove the appropriate circuit fuse or lock o
MCB.
The lamp supplied with this tting is a consumable
part and therefore may be outside of any warranty
oered.
This unit is suitable for indoor and outdoor use.
This product is suitable for use in living areas, and
Bathroom Zone 2 and outsides of zones. If being
tted in a bathroom a 30mA RCD must be used.
Bathroom Zones Diagram
ZONE 2
ZONE 2
60cm
radius
from tap
This product is designed for permanent connection
to xed wiring: this must be a suitable circuit
(protected with the appropriate MCB or fuse).
This product is suitable for installation on sur faces
with normal ammability e.g. wood, plasterboard
and masonry. It is not suitable for use on highly
ammable sur faces (e.g. polystyrene, textiles).
Before making xing hole(s), check that there are no
obstructions hidden beneath the mounting surface
such as pipes or cables.
ZONE 1
225cm
ZONE 0
60cm240cm
When choosing the location for your new tting,
give consideration to the ease and frequency of
lamp changes. The tting should not be installed in a
position where it will be dicult to reach.
When choosing the location for your new tting,
ensure that the xings will be anchored in a solid
surface e.g. concrete, brick or a joist—do not x
directly onto panelling, cladding, plasterboard etc.
Do not attach to surfaces which are damp, freshly
painted or otherwise electrically conductive (e.g.
metallic surfaces).
When making connections ensure that the terminals
are tightened securely and that no strands of wire
protrude. Check that the terminals are tightened
onto the bared conductors and not onto any
insulation.
This product must be connected to earth
termination.
You are advised at every stage of your installation to
double-check any electrical connections you have
made. After you have completed your installation
there are electrical tests that should be carried out,
these tests are specied in the current IEE wiring and
building regulations.
NOTE: Very frequent switching can shorten the
life of the lamp. If lighting controls are used with
this product (e.g PIR or mircowave sensor) then to
minimise this, it is recommended to adjust the time
to the maximum setting.
EVENTUALLY, YOU MAY WANT TO
REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from
Electrical and Electronic Equipment (European
“WEEE Directive” eective August 2005—UK
WEEE Regulations eective 2nd Januar y 2007).
Environment Agency Registered Producer: WEE/
GA0248QZ.
WHEN YOUR PRODUCT COMES TO THE END OF
ITS LIFE OR YOU CHOOSE TO REPL ACE IT, PLEASE
RECYCLE IT WHERE FACILITIES EXIST DO NOT
DISPOSE WITH HOUSEHOLD WASTE.
IF YOU EXPERIENCE PROBLEMS:
If you believe your product is defec tive, please return
it to the place where you bought it. Our Technical
Team will gladly advise on any Eterna Lighting
product, but may not be able to give specic
instructions regarding individual installations.
For breakage information visit:
www.eterna-lighting.co.uk
INSTALLATION:
Choose the location for your new tting according to
the conditions listed opposite.
01. Hold the base of the tting and gently turn the
diuser and decorative trim anti- clockwise and
lift o.
02. Remove the uorescent lamp.
03. Loosen the three screws retaining the gear tray,
slide free from xings, lift out and let the gear tray
hang on the retaining strap.
04. Drill holes in the back of your tting for your
xing screws. Use a drill bit sized appropriately to
your xing screws (not supplied).
05. Using the back of your tting as a template,
mark the position of your xing holes on your
mounting sur face.
06. Prepare the holes in your mounting sur face as
appropriate for your xings.
07. Pierce the rubber grommet in the back of your
tting making a hole just large enough to make a
tight t around the incoming mains cable.
08. Thread the cable through the grommet and oer
the tting to the wall/ceiling.
09. Secure the t ting in place. Note, if protection
against ingress of moisture is required, the heads
of screws must be covered with a silicone or
similar sealant.
10. Check that the grommet is still correctly tted in
the cable entry hole and around the incoming
cable.
11. Make the electrical connections to the gear tray
according to the colour codes below:
Live: Brown
Neutral: Blue
Earth: Green and Yellow
12. Oer the gear tray into position locating on the
three screws, slide into place and tighten the
three retaining screws.
13. Fit the lamp pressing into position until the lamp
has clicked into place and it is held securely.
14. Oer the diuser and decorative trim onto the
top of the tting and turn clockwise until they are
held securely.
15. Restore the power and switch on.
CLEANING:
Clean this product only with a soft dry cloth.
The shade(s) may be removed and washed in a
mild detergent solution. Make sure the shade is
completely dry before putting back on your light
tting.
Do not use any chemical or abrasive cleaners.
LAMP REPLACEMENT:
01. Switch o the electricity at the mains.
02. Turn the diuser anti-clockwise and lift o.
03. Pull the lamp straight out of the tting and press
a new one back into position ensuring that it is
retained securely.
04. Replace the diuser and turn clockwise so that it
is retained securely.
Regulations require the recycling of Waste from Electrical
and Electronic Equipment (European “WEEE Directive”
eective August 2005—UK WEEE Regulations eective
2nd January 2007). Environment Agency Registered
Producer: WEE/GA0248QZ.
WHEN YOUR PRODUCT COMES TO THE END OF IT S
LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE R ECYCLE
IT WHER E FACILITIES EXIST DO N OT DISPOSE WITH
HOUSEHOLD WASTE.
INDUSTRIAL BATTERIES:
Within cer tain products Eterna Lighting Ltd places lead
acid, lithium ion, nickel cadmium & nickel metal hydride
batteries on the market. Industrial batteries are subject
to waste regulation under the Waste Batteries and
Accumulators Regulations 2009 and should be disposed
of responsibly. Purchasers may be able to dispose of their
waste industrial batteries locally via legitimate licensed
trade waste contractors. Eterna is obliged to take back,
free of charge and within a reasonable time, waste
industrial batteries of the same chemistry supplied to a
Purchaser, for treatment and recycling and is required
to do this in any calendar year new industrial batteries
are placed on the market. In certain circumstances, this
may include batteries not originally supplied by Eterna.
If any Purchaser requires Eterna to take back Industrial
batteries, they should write to the Operations Director,
Eterna Lighting Ltd, Huxley Close, NN8 6AB, who will then
advise on the necessary arrangements for the receipt,
proper treatment and recycling of, the waste industrial
batteries.
CLEANING:
Clean this t ting only with a soft dry cloth.
Do not use any chemical or abrasive cleaners.
IF YOU EXPERIENCE PROBLEMS:
If you believe your product is defective, please return it
to the place where you bought it. Our Technical Team will
gladly advise on any Eterna Lighting product, but may not
be able to give specic instructions regarding individual
installations.
For breakage information visit:
www.eterna-lighting.co.uk
These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE USING YOUR NEW FITTING
PLEASE RETAIN FOR FUTURE REFERENCE
Made in ChinaIssue 0516
Page 4
READ THIS FIRST:
SW
L1
N
Remove link to makeit non-mantained
N
L1
N
Switch supply
N
L
L
L
L1
L
L1
N
Remove link to makeit non-mantained
N
L
L
THIS INSTRUCTION LEAFLET SHOULD BE READ IN
CONJUNC TION WITH THE USER INSTRUCTIONS
FOR THE FITTING INTO WHICH YOU ARE
INSTALLING THE GEAR TRAY
This emergency control gear must be installed by a
competent person.
This emergency control gear has been designed for
installation into the Eterna range of circular bulkhead
light ttings (code CF28CR/MS/ WH) which has
been designed specically to allow conversion for
emergency use.
This emergency control gear may be incorporated
into any other tting that has been designed
for emergency use, providing that the tting is
suciently large to allow circulation of air inside
and correct dissipation of any build up of heat. For
protection against possible electric shock, it must be
xed so that it is not possible to touch any live par t
(including the terminals) when opening the tting to
change the lamp. Use of this gear inside any tting
other than that for which it was specically designed
(see model reference above) may invalidate any
warranty given at the time of purchase.
As the buyer, installer and/or user of this product it
is your own responsibility to ensure that this ballast
is t for the purpose for which you have intended
it. Eterna Lighting cannot accept any liability for
loss, damage or premature failure resulting from
inappropriate use.
This product is designed and constructed according
to the principles of the appropriate British Standards
and is intended for normal service. Use of this ballast
in any other environment where higher than normal
ambient temperatures are likely may result in a
foreshortened working life – for example lighting
public or shared spaces or in nursing / care home
facilities. If the product is controlled with a PIR this
can also shor ten the lifetime of the ballast and the
lamp.
Disconnec t the tting from the electrical supply
before ash or high voltage testing.
This product is designed for permanent installation
in a light tting which should be connected to a
dedicated constant live supply for battery charging
and switched live supply for operation of the lamp.
This circuit should be protected with a 5 or 6 Amp
MCB or fuse.
When making connections, ensure that the terminals
clamp the stripped conductors securely and that no
strands of wire protrude. Check that the terminals are
tightened onto the bared conductors and not onto
any insulation.
This product must be connected to Earth.
You are advised at every stage of your installation to
double-check any electrical connections you have
made.
NOTE: Very frequent switching can shorten the
life of the lamp. If lighting controls are used with
this product (e.g PIR or mircowave sensor) then to
minimise this, it is recommended to adjust the time
to the maximum setting.
The lamps (bulbs/tubes) & batteries supplied with
this tting are consumable parts and therefore may
be outside of any warranty oered.
INSTALLATION:
Insert loose battery wire into the ballast. (See Fig. 3
opposite).
Fit the gear tray to your light tting according to the
instructions supplied with the light tting.
Make connections according to Fig. 1 & 2 below:
Fig 1 - UNSWITCHED MAINTAINED UNIT
N
N
L
L
L1
Remove link to make
it non-mantained
Fig 2 - SWITCHED MAINTAINED UNIT
N
N
L
L
SW
L1
L1
Switch supply
Connections to the ballast/inverter control unit are
made as shown in Fig. 3 opposite.
Fit a lamp and reassemble the tting according to
the instructions supplied with the tting.
Terminate wires as above and restore the power and
switch on. Green LED will indicate healthy charging
circuit.
BATTERY REPLACEMENT:
If after routine operation check, the lamp does not
remain lit for the three hour period, a new batter y
pack may be required.
Switch o the electricity at the mains.
Allow batteries to fully discharge then reconnect to
supply and allow to charge for 24 hours.
Test again for 3 hours, if light does not remain lit
change the battery pack as follows:
Remove the diuser and trim (Eterna CF28 range).
Loosen the three screws indicated on the gear tray,
slide and lif t o.
Unplug the battery lead from the ballast (push t
connectors).
Undo the two screws that secure the battery pack in
place and remove battery pack from the gear tray.
Write current date on the new battery pack.
Fit new battery pack securing in place using the
screws removed from the old pack (or suitable
alternatives).
Reconnec t battery pack.
Replace gear tray, slide and secure in position by
tightening the three screws.
Replace diuser and the trim (Eterna CF28 range).
Restore power and allow to charge for at least 24
hours.
Perform full operation check and update test record.
Fig 3 - WIRING DIAGRAM
Brown: Switchable
Blue: Neutral
Brown: Unwitched
Yellow / Green: Earth
Pink + LED +VE
Pink - LED -VE
Red: Battery +VE
Black: Battery -VE
LED
indicator
+++
- - -
Emergency Module
OPERATION CHECKS:
Periodic testing should be carried out to ensure
emergency lighting is operating correctly.
Interruption of the supply, causing the tting to be
energised from the battery, should be carried out by
the operation of a local keyswitch or other isolation
device. During this period all ttings should be
examined visually to ensure that they are functioning
correctly. At the end of the test period the supply
shall be restored and all indicator lamps or devices
checked to ensure that the normal supply has been
restored.
DA ILY:
Visual inspection of the batter y charge LED.
EACH MONTH:
Isolate the power supply for a period sucient to
ensure that each lamp is illuminated. Endorse the
test record form supplied.
ONCE EACH YEAR:
Isolate the power supply and check that the light is
still illuminated after 3 hours. Endorse the test record
form.
Because of the possibility of a failure of the normal
lighting supply occurring shortly after a period of
testing of the emergency lighting system or during
the subsequent recharge period, all full duration
tests shall wherever possible be undertaken
preceding time of low risk to allow for battery
recharge.
NOTE: please keep this instruction booklet and
the test record in a safe place. A re ocer or
other authorised person may want to see your
record of inspection and testing.
IMPORTANT NOTES:
The ballast and control gear must be operated only
within the enclosure supplied. The gear must not be
operated outside of the enclosure.
The battery charging circuit and DC ballast are
separated from the mains by at least basic (single
layer) insulation.
When energised by a constant mains supply, the
battery will be constantly charged whether or not
the lamp is illuminated. On failure of the constant
mains supply, the tting will switch automatically
using transistorised switching from battery charging
to battery discharge powering the lamp whether
or not the lamp was illuminated before the power
failure. Both the mains and battery supplies
incorporate fuse protection: see tting for location
and rating.
Page 5
Product
Code:
Product
Location:
Product
Description:
INSTALLATION, MAINTENANCE
AND OPERATION CHECK RECORD
Year:Year:Year:Year:Year:
Test
Month
01Short
02Short
03Short
04Short
05Short
06Short
SignDateSignDateSignDateSignDateSignDate
Installation
Date:
Installed
By:
Installation
Test Duration:
07Short
08Short
09Short
10Short
11Short
12
3 Hour
Endurance
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.