LAMP SPECIFICATIONS:
Lumens total ux
Rated Wattage 6W
Rated luminous ux 450 lm
Nominal life time of the lamp 35,000 hrs
Colour temperature 4200K
Number of switching cycles
before premature lamp failure
Warm-up time up to 60 % of
the full light output
Dimmable No
LED array dimensions (L/W) 140 x 60mm
Nominal beam angle 120°
Rated power 6W
Rated lamp lifetime 35,000 hrs
Lamp power factor >0.5
Lumen maintenance factor at
end of nominal life
Starting time <0.1s
Colour rendering ≥80
Colour consistency
Rated peak intensity 160cd
Rated beam angle 120°
Voltage 240V
Not suitable for accent lighting
450 lm
≥17,500
Instant full light
≥0.70
Within 6 step
Macadam ellipse
874/2012
MODELNO.
BOPLED6
INSTALLATION INSTRUCTIONS
A guide for qualied electricians
EVENTUALLY, YOU MAY WANT TO
REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from
Electrical and Electronic Equipment (European
“WEEE Directive” eective August 2005—UK
WEEE Regulations eective 2nd January 2007).
Environment Agency Registered Producer: WEE/
GA0248QZ.
WHEN YOUR PRODUC T COMES TO THE END OF
ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE
RECYCLE IT WHERE FACILITIES EXIST DO NOT
DISPOSE WITH HOUSEHOLD WASTE.
Email: sales@eterna-lighting.co.uk / technical@eterna-lighting.co.uk
Visit our website: www.eterna-lighting.co.uk
CLEANING:
Clean this light tting only with a soft dr y cloth.
Do not use any chemical or abrasive cleaners.
IF YOU EXPERIENCE PROBLEMS:
If you believe your product is defective, please return
it to the place where you bought it. Our Technical
Team will gladly advise on any Eterna Lighting
product, but may not be able to give specic
instructions regarding individual installations.
For breakage information visit:
www.eterna-lighting.co.uk
Made in ChinaIssue 1015
Pack contents:
Model:
1 x 6W LED bulkhead
1 x Fixing kit
BOPLED6
6W IP65 LED Polycarbonate Bulkhead
These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION
AND RETAIN FOR FUTURE REFERENCE

READ THIS FIRST:
Check the pack and make sure you have all of the
parts listed on the front of this booklet. If not,
contact the outlet where you bought this product.
This light tting must be installed by a competent
person in accordance with the Building and IEE
Wiring Regulations.
As the buyer, installer and/or user of this product it
is your own responsibility to ensure that this tting
is t for the purpose for which you have intended
it. Eterna Lighting cannot accept any liability for
loss, damage or premature failure resulting from
inappropriate use.
This product is designed and constructed according
to the principles of the appropriate British Standard
and is intended for normal domestic ser vice. Use of
this tting in any other environments for example;
where prolonged periods of use or higher than
normal ambient temperatures, may result in a
shortened working life.
Switch o the mains before commencing installation
and remove the appropriate circuit fuse or lock o
MCB.
Make connections to the electrical supply in
accordance with the following code:
LIVE - Brown or Red
NEUTRAL - Blue or Black
EARTH - Green and Yellow
This unit is suitable for outdoor use.
This product is suitable for installation on surfaces
with normal ammability e.g. wood, plasterboard,
and masonry. It is not suitable for use on highly
ammable surfaces.
Before making xing hole(s), check that there are no
obstructions hidden beneath the mounting surface
such as pipes or cables.
The chosen location of your new tting should allow
for the product to be securely mounted and safely
connected to the mains supply (lighting circuit).
When making connections ensure; that the terminals
are tightened securely and that no strands of wire
protrude. Check that the terminals are tightened
onto the bared conductors and not onto any
insulation. Wrap loose terminal blocks well with
insulating tape.
IMPORTANT: you are advised at ever y stage of
your installation to double-check any electrical
connections you have made. Af ter you have
completed your installation there are electrical tests
that should be carried out: these tests are specied
in the Wiring Regulations (BS7671) referred to in the
Building Regulations.
INSTALLATION:
01) Choose the location for your new light tting
giving consideration to the points listed opposite.
02) To access the tting, remove the 2 retaining
screws and remove diuser.
03) Drill out xing holes in the back of the tting,
according to your chosen xing method. All four
blind holes are pre-cast within the back housing.
This enables the tting to be mounted securely to
a solid surface.
04) Choose the point for cable entry and remove
(with care) the corresponding knock-out using a
20mm hole saw. DO NOT USE A HAMMER.
05) Using the tting as a template, mark the
location of your xing holes on the mounting
surface.
06) Secure the tting into position using suitable
screws and washers (xings not supplied).
07) Cover the heads of the screws with silicone
sealant (not supplied), to maintain IP rating.
08) Insert an IP rated grommet or an IP65 cable gland
and lock into position.
09) Thread the supply cable into the tting.
10) Loosen the 3 LED panel screws so you are able to
slide and lif t it o (as shown opposite).
11) Make the electrical connections by connecting
to the 3 way terminal block (on the underside of
the LED panel) according to the colour code listed
opposite and noting the terminal identication in
the tting.
12) Re-ax LED panel and tighten the 3 screws
taking care not to over tighten, as this may
damage the unit.
13) Restore power and switch on.
Wire & install
cable gland
THIS SIDE
for ease
DO NOT
USE A
HAMMER!
1) Loosen (DO NOT REMOVE) the below 3 screws
2) Slide and lift out the LED panel
Terminal block on reverse of LED panel
Blue
(Power Cable)
Yellow & Green
(Power Cable)
Brown
(Power Cable)
N
L
Blue or Black
(Neutral)
Yellow & Green
(Earth)
Brown or Red
(Live)
Slide
& lift