Eterna Lighting BOPLED6 Installation Instructions

LAMP SPECIFICATIONS:
Lumens total ux
Rated Wattage 6W
Rated luminous ux 450 lm
Nominal life time of the lamp 35,000 hrs
Colour temperature 4200K
Number of switching cycles before premature lamp failure
Warm-up time up to 60 % of the full light output
Dimmable No
LED array dimensions (L/W) 140 x 60mm
Nominal beam angle 120°
Rated power 6W
Rated lamp lifetime 35,000 hrs
Lamp power factor >0.5
Lumen maintenance factor at end of nominal life
Starting time <0.1s
Colour rendering ≥80
Colour consistency
Rated peak intensity 160cd
Rated beam angle 120°
Voltage 240V
Not suitable for accent lighting
450 lm
≥17,500
Instant full light
≥0.70
Within 6 step
Macadam ellipse
874/2012
MODELNO.
BOPLED6
INSTALLATION INSTRUCTIONS
EVENTUALLY, YOU MAY WANT TO REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from Electrical and Electronic Equipment (European “WEEE Directive” eective August 2005—UK WEEE Regulations eective 2nd January 2007). Environment Agency Registered Producer: WEE/ GA0248QZ.
WHEN YOUR PRODUC T COMES TO THE END OF ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE RECYCLE IT WHERE FACILITIES EXIST  DO NOT DISPOSE WITH HOUSEHOLD WASTE.
Email: sales@eterna-lighting.co.uk / technical@eterna-lighting.co.uk
Visit our website: www.eterna-lighting.co.uk
CLEANING:
Clean this light tting only with a soft dr y cloth.
Do not use any chemical or abrasive cleaners.
IF YOU EXPERIENCE PROBLEMS:
If you believe your product is defective, please return it to the place where you bought it. Our Technical Team will gladly advise on any Eterna Lighting product, but may not be able to give specic instructions regarding individual installations.
For breakage information visit: www.eterna-lighting.co.uk
Made in ChinaIssue 1015
Pack contents:
Model:
1 x 6W LED bulkhead
1 x Fixing kit
BOPLED6
6W IP65 LED Polycarbonate Bulkhead
These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION
AND RETAIN FOR FUTURE REFERENCE
READ THIS FIRST:
Check the pack and make sure you have all of the parts listed on the front of this booklet. If not, contact the outlet where you bought this product.
This light tting must be installed by a competent person in accordance with the Building and IEE Wiring Regulations.
As the buyer, installer and/or user of this product it is your own responsibility to ensure that this tting is t for the purpose for which you have intended it. Eterna Lighting cannot accept any liability for loss, damage or premature failure resulting from inappropriate use.
This product is designed and constructed according to the principles of the appropriate British Standard and is intended for normal domestic ser vice. Use of this tting in any other environments for example; where prolonged periods of use or higher than normal ambient temperatures, may result in a shortened working life.
Switch o the mains before commencing installation and remove the appropriate circuit fuse or lock o MCB.
Make connections to the electrical supply in accordance with the following code:
LIVE - Brown or Red NEUTRAL - Blue or Black EARTH - Green and Yellow
This unit is suitable for outdoor use.
This product is suitable for installation on surfaces with normal ammability e.g. wood, plasterboard, and masonry. It is not suitable for use on highly ammable surfaces.
Before making xing hole(s), check that there are no obstructions hidden beneath the mounting surface such as pipes or cables.
The chosen location of your new tting should allow for the product to be securely mounted and safely connected to the mains supply (lighting circuit).
When making connections ensure; that the terminals are tightened securely and that no strands of wire protrude. Check that the terminals are tightened onto the bared conductors and not onto any insulation. Wrap loose terminal blocks well with insulating tape.
IMPORTANT: you are advised at ever y stage of your installation to double-check any electrical connections you have made. Af ter you have completed your installation there are electrical tests that should be carried out: these tests are specied in the Wiring Regulations (BS7671) referred to in the Building Regulations.
INSTALLATION:
01) Choose the location for your new light tting giving consideration to the points listed opposite.
02) To access the tting, remove the 2 retaining screws and remove diuser.
03) Drill out xing holes in the back of the tting, according to your chosen xing method. All four blind holes are pre-cast within the back housing. This enables the tting to be mounted securely to a solid surface.
04) Choose the point for cable entry and remove
(with care) the corresponding knock-out using a 20mm hole saw. DO NOT USE A HAMMER.
05) Using the tting as a template, mark the location of your xing holes on the mounting surface.
06) Secure the tting into position using suitable
screws and washers (xings not supplied).
07) Cover the heads of the screws with silicone sealant (not supplied), to maintain IP rating.
08) Insert an IP rated grommet or an IP65 cable gland
and lock into position.
09) Thread the supply cable into the tting.
10) Loosen the 3 LED panel screws so you are able to slide and lif t it o (as shown opposite).
11) Make the electrical connections by connecting to the 3 way terminal block (on the underside of the LED panel) according to the colour code listed opposite and noting the terminal identication in the tting.
12) Re-ax LED panel and tighten the 3 screws taking care not to over tighten, as this may damage the unit.
13) Restore power and switch on.
Wire & install cable gland
THIS SIDE
for ease
DO NOT USE A HAMMER!
1) Loosen (DO NOT REMOVE) the below 3 screws
2) Slide and lift out the LED panel
Terminal block on reverse of LED panel
Blue
(Power Cable)
Yellow & Green
(Power Cable)
Brown
(Power Cable)
N
L
Blue or Black (Neutral)
Yellow & Green (Earth)
Brown or Red (Live)
Slide & lift