READ THIS FIRST:
Check the pack and m ake sure you have all of the
parts liste d on the front of this bookle t. If not,
contact the outlet where you bought this product.
This produ ct must be install ed by a competent
person in accordance with the current building
and IEE wiring regulations.
As the buyer, install er and/or user of this product it
is your own responsi bility to ensure that this tt ing
is t for the purpo se for which you have intended
it. Eterna Lightin g cannot accept any liability fo r
loss, damage or premature failure resulting from
inappropriate use.
Switch o the mains be fore commencing installati on
and remove the appro priate circuit fuse or lock o
MCB.
This unit is suitable for indoor and outdoor use.
This produc t is designed for permanent co nnection
to xed wiring: this m ust be a suitable circuit
(protected w ith the appropriate MCB or fuse).
This produc t is suitable for installatio n on surfaces
with normal ammability e.g. wood, plasterboard
and masonry. It is not s uitable for use on highly
ammable sur faces (e.g. polystyren e, textiles).
Before makin g xing hole(s), check that there are no
obstructi ons hidden beneath the mount ing surface
such as pipes or cab les.
When making con nections ensure that the ter minals
are tightened se curely and that no strands of wi re
protrude. Chec k that the terminals are tightene d
onto the bared cond uctors and not onto any
insulation.
This produc t is double insulated; do not conne ct
either the blue /brown wires or any part to the e arth
terminal.
You are advised at ever y stage of your installatio n to
double-check any electrical connections you have
made. After you h ave completed your installatio n
there are elec trical tests that should b e carried out,
these tests are sp ecied in the current IEE wir ing and
building regulations.
LAMP REPLACEMENT: INSTALLATION:
Choose the loc ation for your new light tting
according to the conditions listed opposite.
01) Isolate the mains before comme ncing installation.
02) Using the base as a template, ma rk the position of
the xing holes.
03) Undo the two screws ho lding the diuser in place
and unscrew the LED ar ray.
04) Pierce the rubbe r grommet and thread the mains
supply cable th rough it.
NOTE: Do not make th e holes in the grommet
too large. They sh ould be tight on the cable to
ensure a water-tight seal.
05) Make the terminal conn ections:
Live (L), Neutral (N).
06) Replace the LED ar ray and diuser.
07) Restore power an d switch on.
The light source cont ained in this luminaire
shall only be rep laced by the manufacturer,
service age nt or a similar qualied pers on.
CAUTION, RISK OF ELECTRIC SHOCK.
The light source is designed to last the lifetime of the
luminaire.