LED LAMP SPECIFICATIONS:
Lumens total ux
Rated Wattage 7W
Nominal life time of the lamp 35,000 hrs
Colour temperature 3100K
Number of switching cycles
before premature lamp
failure
Warm-up time up to 60 % of
the full light output
Dimmable No
Nominal beam angle 120°
Rated power 7W
Rated lamp lifetime 35,000 hrs
Lamp power factor >0.5s
Lumen maintenance factor at
end of nominal life
Starting time <0.1s
Colour rendering ≥80
Colour consistency
Rated peak intensity 110cd
Rated beam angle 120°
Voltage / Frequency 240V~50Hz
Not suitable for accent lighting
420 lm
≥15,000
Instant full light
≥0.70
Within 6 step
Macadam ellipse
INSTALLATION INSTRUCTIONS
A guide for qualied electricians
EVENTUALLY, YOU MAY WANT TO
REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from
Electrical and Electronic Equipment (European
“WEEE Directive” eective August 2005—UK
WEEE Regulations eective 2nd January 2007).
Environment Agency Registered Producer: WEE/
GA0248QZ.
WHEN YOUR PRODUC T COMES TO THE END OF
ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE
RECYCLE IT WHERE FACILITIES EXIST DO NOT
DISPOSE WITH HOUSEHOLD WASTE.
Email: sales@eterna-lighting.co.uk / technical@eterna-lighting.co.uk
Visit our website: www.eterna-lighting.co.uk
IF YOU EXPERIENCE PROBLEMS:
If you believe your product is defective, please return
it to the place where you bought it. Our Technical
Team will gladly advise on any Eterna Lighting
product, but may not be able to give specic
instructions regarding individual installations.
Made in ChinaIssue 0318
Pack contents:
• Full lantern
• Mounting xtures
Model:
VECOFBK
LED Economy Full Lantern
These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION
AND RETAIN FOR FUTURE REFERENCE
READ THIS FIRST:
Check the pack and make sure you have all of the
parts listed on the front of this booklet. If not,
contact the outlet where you bought this product.
This product must be installed by a competent
person in accordance with the current building and
IEE wiring regulations.
As the buyer, installer and/or user of this product it
is your own responsibility to ensure that this tting
is t for the purpose for which you have intended
it. Eterna Lighting cannot accept any liability for
loss, damage or premature failure resulting from
inappropriate use.
This light tting must be installed in accordance with
the Building Regulations.
Switch o the mains before commencing installation
and remove the appropriate circuit fuse or lock o
MCB.
Suitable for outdoor use.
This product is suitable for installation on surfaces
with normal ammability, e.g. wood, plasterboard,
masonry. It is not suitable for use on highly
ammable sur faces (e.g. polystyrene, textiles).
Before making xing hole(s), check that there are no
obstructions hidden beneath the mounting surface
such as pipes or cables.
The chosen location of your new tting should allow
for the product to be securely mounted and safely
connected to the mains supply (lighting circuit).
If the location of your new tting requires the
provision of a new electrical supply, the supply
must conform with the requirements of the Building
Regulations.
This product is designed for permanent connection
to xed wiring: this should be either a suitable
lighting circuit (protected with a 5 or 6 Amp MCB or
fuse) or a fused spur (with a 3 Amp fuse) via a fused
connection unit. We recommend that the supply
incorporates a switch for ease of operation.
Make connections to the electrical supply in
accordance with the following code:
Live - Brown or Red
Neutral - Blue or Black
This tting is double insulated. DO NOT CONNECT
ANY PART TO E ARTH.
You are advised at every stage of your installation to
double-check any electrical connections you have
made. After you have completed your installation
there are electrical tests that should be carried out:
these tests are specied in the Wiring Regulations
(BS7671) referred to in the Building Regulations.
LAMP REPLACEMENT:
The light source is designed to last the lifetime of the
luminaire.
The light source contained in this luminaire
shall only be replaced by the manufacturer,
service agent or a similar qualied person.
CAUTION, RISK OF ELECTRIC SHOCK.
INSTALLATION:
01) Undo the nuts on the backplate of the tting and
detach.
02) Using the back of the tting as a template, mark
the location of the xing holes.
03) Pierce the rubber grommet in the back of the
tting. Make the hole as small as possible so that
a good water tight seal is maintained when the
cable has been threaded through.
04) Thread the cable through the grommet.
05) Secure the tting to the wall using xings.
06) Make the connections to the terminal block
according to the colour code. Connect the cable
from the main body of the tting observing the
colour code.
07) Oer the main body on to the back plate, and
tighten nuts to secure, ensuring the two gaskets
are in place.
08) Restore the power and switch on.
CLEANING:
Clean this tting only with a soft dry cloth.
Do not use any chemical or abrasive cleaners.
Blue
(Power Cable)
Brown
(Power Cable)
Back of tting
LN
LN
Backplate
nut
Rubber
grommet
Backplate
nut
Blue
(Power Cable)
Brown
(Power Cable)