WHERE TO F IT YOUR PIR FLOODLI GHT:
To achieve best results we su ggest you take the
following points into consideration:
Do not mount on a sur face that has vibration.
Ideally the PIR o od light should be mounted 3
metres above the ar ea to be scanned (refer to g.1
below).
To avoid damage to the unit do not ai m sensor
towards sun.
Avoid positioning th e sensor unit adjacent to a
bright light source w hich may prevent the unit from
operating whe n the lux control is set to operate i n
dark conditions.
Avoid nuisance / false t riggering by directing s ensor
away from:
• Trees and shrubs
• Reective su rfaces such as smooth white w alls
• Swimming pools
• Heat sources such as b oiler ues
The PIR sensor sc anning specications
(approximately 10 metres at 140° ) may vary slightly
depending on the mounting height and location.
The detecti on range of the unit may also alter w ith
temperature cha nge. Before selectin g a place to
install your PIR o odlight you should note that
movement across the s can area is more eective
than movement dire ctly towards or away from the
sensor. (Refer to g. 2 opposite).
If movement is made w alking directly towards o r
away from the senso r and not across the sensor
the apparent dete ction range will be subs tantially
reduced (refer to g . 3 below).
INTRODUCTION:
The oodlight i ncorporates a PIR (Passive Infra R ed)
sensing device wh ich continuously scans a prese t
operating zon e and immediately switches th e light
on when it detec ts movement in that area.
This means that whe never movement is detecte d
within the range o f the sensor the light will switch
on automaticall y to illuminate the area you have
selected to l ight. While there is movement wi thin
range of the unit th e light will remain on.
READ THIS FIRST:
Check the pack and m ake sure you have all of the
parts liste d on the front of this bookle t. If not,
contact the outlet where you bought this product.
This produc t must be installed by a compet ent
person in accord ance with the current building a nd
IEE wiring regulations.
As the buyer, install er and/or user of this product it
is your own responsi bility to ensure that this tt ing
is t for the purpo se for which you have intended
it. Eterna Lightin g cannot accept any liability fo r
loss, damage or premature failure resulting from
inappropriate use.
This product is designed and constructed according
to the principles of the appropriate British Standard.
Switch o the mains be fore commencing installati on
and remove the appro priate circuit fuse or lock o
MCB.
This unit is suitab le for outdoor use.
This produc t is designed for permanent co nnection
to xed wiring: this m ust be a suitable circuit
(protected w ith the appropriate MCB or fuse).
Before makin g xing hole(s), check that there are no
obstructi ons hidden beneath the mount ing surface
such as pipes or cab les.
Make sure that the xi ngs are strong enough to
support the co nsiderable weight of the t ting and
hold it rigidly.
The lamp must be p ositioned so that there is at
least 1M between th e luminaire and any illuminated
surface.
When making con nections ensure that the ter minals
are tightened se curely and that no
strands of wire p rotrude. Check that the termin als are
tightened onto the b ared conductors and not o nto
any insulation.
This product is double insulated. DO NOT CONNECT
ANY PART TO EARTH.
This produc t is not intended to be used by childr en
and persons wi th sensory, physical and/or ment al
impairments th at would prevent them from using i t
saf ely.
You are advised at ever y stage of your installatio n to
double-check any electrical connections you have
made. After you h ave completed your installatio n
there are elec trical tests that should b e carried out,
these tests are sp ecied in the current IEE wir ing and
building regulations.
CLEANING:
• To avoid dust build-up and ensur e proper
functionin g of the oodlight, please w ipe the
sensor lens light ly with a damp cloth every 3
months.
• Disconnect the po wer and clean the exterior o nly of
this tting wit h a moist (not wet) cloth.
• Do not use any chemic al or abrasive cleaners.
LAMP REPLACEMENT:
The light source of th is luminaire is not replaceable;
when the light sou rce reaches its end of life the
whole luminaire shall be replaced.
SPECIFICATIONS:
• Detection rang e: max. 10M at approx. 140° scan
• Duration time adjust ment: (10±2) seconds to (10±2)
minutes
• Detection c ircuitry: Passive Infra -Red (PIR)
• Weather proof: IP54
• Power required: 240V~ 50 Hz
• Recommended powe r supply cable: H05RN- F 3G
1.0m m
2
• Protection: Cla ss II
• Lux level: adjust able
NOTE: the PIR head c an be rotated 90° lef t or right
3M
4M 8M 10M
140˚
Approx
Fig 1
EFFECTIVE:
Movement across
scan area
LESS EFFECTIVE:
Movement
directly in front
of scan area
Fig 2
Fig 3
PG 2 PG 3