EVENTUALLY, YOU MAY WANT TO REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from Electrical and Electronic Equipment (European “WEEE Direc tive” eective August 20 05—UK WEEE Regulation s eective 2nd January 20 07). Environment Agenc y Registered Producer : WEE/ GA0248Q Z.
WHEN YOUR PR ODUCT COMES TO TH E END OF ITS LIFE OR YO U CHOOSE TO REPLACE I T, PLEASE RECYCLE IT W HERE FACILITIES E XIST  DO NOT DISPOSE WITH HOUSEHOLD WASTE.
IF YOU EXPERIENCE PROBLEMS:
If you believe your p roduct is defective, p lease return it to the place where yo u bought it. Our Technical Team will gladly advise on any Eterna Lighting product, bu t may not be able to give specic instructions regarding individual installations.
874/2012
MODELNO.
FOCUS RANGE
Email: sales@eterna-lighting.co.uk / technical@eterna-lighting.co.uk
Visit our website: www.eterna-lighting.co.uk
Made in ChinaIssue 1016
Pack contents:
1 x Focus LED oodlight with PIR
10W
20W
LAMP SPECIFICATIONS: 10W 20W
Lumens total ux
680 lm 1500 lm
Lumens 90° ux
640 lm 1400 lm
Rated Wattage 10W 20W
Rated luminous ux 680 lm 1360 lm
Nominal life time of the lamp 25,000 hrs 25,000 hrs
Colour temperature 4200K 4200K
Number of switching cycles before premature lamp failure
15,000 15,000
Warm-up time up to 60 % of the full light output
Instant full light Instant full light
Dimmable No No
LED array dimensions (Ø) 29mm 29mm
Nominal beam angle 40° 100°
Rated power 10W 20W
Rated lamp lifetime 25,000 hrs 25,000 hrs
Lamp power factor >5 >5
Lumen maintenance factor at end of nominal life
70% 70%
Starting time 0.17s 0.34s
Colour rendering ≥65 ≥65
Colour consistency
Within 6 step
Macadam ellipse
Within 6 step
Macadam ellipse
Rated peak intensity 300cd 600cd
Rated beam angle 40° 100°
Voltage 240V 240V
WHERE TO F IT YOUR PIR FLOODLI GHT:
To achieve best results we su ggest you take the following points into consideration:
Do not mount on a sur face that has vibration.
Ideally the PIR o od light should be mounted 3 metres above the ar ea to be scanned (refer to g.1 below).
To avoid damage to the unit do not ai m sensor towards sun.
Avoid positioning th e sensor unit adjacent to a bright light source w hich may prevent the unit from operating whe n the lux control is set to operate i n dark conditions.
Avoid nuisance / false t riggering by directing s ensor away from:
• Trees and shrubs
• Reective su rfaces such as smooth white w alls
• Swimming pools
• Heat sources such as b oiler ues
The PIR sensor sc anning specications (approximately 10 metres at 140° ) may vary slightly depending on the mounting height and location.
The detecti on range of the unit may also alter w ith temperature cha nge. Before selectin g a place to install your PIR o odlight you should note that movement across the s can area is more eective than movement dire ctly towards or away from the sensor. (Refer to g. 2 opposite).
If movement is made w alking directly towards o r away from the senso r and not across the sensor the apparent dete ction range will be subs tantially reduced (refer to g . 3 below).
INTRODUCTION:
The oodlight i ncorporates a PIR (Passive Infra R ed) sensing device wh ich continuously scans a prese t operating zon e and immediately switches th e light on when it detec ts movement in that area.
This means that whe never movement is detecte d within the range o f the sensor the light will switch on automaticall y to illuminate the area you have selected to l ight. While there is movement wi thin range of the unit th e light will remain on.
READ THIS FIRST:
Check the pack and m ake sure you have all of the parts liste d on the front of this bookle t. If not, contact the outlet where you bought this product.
This produc t must be installed by a compet ent person in accord ance with the current building a nd IEE wiring regulations.
As the buyer, install er and/or user of this product it is your own responsi bility to ensure that this tt ing is t for the purpo se for which you have intended it. Eterna Lightin g cannot accept any liability fo r loss, damage or premature failure resulting from inappropriate use.
This product is designed and constructed according to the principles of the appropriate British Standard.
Switch o the mains be fore commencing installati on and remove the appro priate circuit fuse or lock o MCB.
This unit is suitab le for outdoor use.
This produc t is designed for permanent co nnection to xed wiring: this m ust be a suitable circuit (protected w ith the appropriate MCB or fuse).
Before makin g xing hole(s), check that there are no obstructi ons hidden beneath the mount ing surface such as pipes or cab les.
Make sure that the xi ngs are strong enough to support the co nsiderable weight of the t ting and hold it rigidly.
The lamp must be p ositioned so that there is at least 1M between th e luminaire and any illuminated surface.
When making con nections ensure that the ter minals are tightened se curely and that no strands of wire p rotrude. Check that the termin als are tightened onto the b ared conductors and not o nto any insulation.
This product is double insulated. DO NOT CONNECT
ANY PART TO EARTH.
This produc t is not intended to be used by childr en and persons wi th sensory, physical and/or ment al impairments th at would prevent them from using i t saf ely.
You are advised at ever y stage of your installatio n to double-check any electrical connections you have made. After you h ave completed your installatio n there are elec trical tests that should b e carried out, these tests are sp ecied in the current IEE wir ing and building regulations.
CLEANING:
• To avoid dust build-up and ensur e proper functionin g of the oodlight, please w ipe the sensor lens light ly with a damp cloth every 3 months.
• Disconnect the po wer and clean the exterior o nly of this tting wit h a moist (not wet) cloth.
• Do not use any chemic al or abrasive cleaners.
LAMP REPLACEMENT:
The light source of th is luminaire is not replaceable; when the light sou rce reaches its end of life the whole luminaire shall be replaced.
SPECIFICATIONS:
• Detection rang e: max. 10M at approx. 140° scan
• Duration time adjust ment: (10±2) seconds to (10±2) minutes
• Detection c ircuitry: Passive Infra -Red (PIR)
• Weather proof: IP54
• Power required: 240V~ 50 Hz
• Recommended powe r supply cable: H05RN- F 3G
1.0m m
2
• Protection: Cla ss II
• Lux level: adjust able
NOTE: the PIR head c an be rotated 90° lef t or right
3M
4M 8M 10M
140˚
Approx
Fig 1
EFFECTIVE:
Movement across scan area
LESS EFFECTIVE:
Movement directly in front of scan area
Fig 2
Fig 3
PG 2 PG 3