Eterna SSRCDMC, SSRCDWH Installation Instructions Manual

Issue 2014
Model:
SSRCDMC / SSRCDWH - Single Fused RCD Spur
TWSRCDMC / TWSRCDWH - Twin Unswitched RCD Socket
These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION
AND RETAIN FOR FUTURE REFERENCE
1 x Fitting
2 x M3 screws
FOR PRODUCT ADVICE:
• T: 01933 673 144
• F: 01933 678 083
• E: sales@eterna-lighting.co.uk
Visit our website:
www.eterna-lighting.co.uk
INSTALLATION INSTRUCTIONS
A guide for qualied electricians
EVENTUALLY, YOU MAY WANT TO REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from Electrical and Electronic Equipment (European “WEEE Direc tive” eective August 20 05—UK WEEE Regulation s eective 2nd January 20 07). Environment Agenc y Registered Producer : WEE/ GA0248Q Z.
WHEN YOUR PR ODUCT COMES TO TH E END OF ITS LIFE OR YO U CHOOSE TO REPLACE I T, PLEAS E RECYCLE IT W HERE FACILITIES E XIST  DO NOT DISPOSE WITH HOUSEHOLD WASTE.
CLEANING:
Clean this ttin g only with a soft dry clo th.
Do not use any chemic al or abrasive cleaners.
IF YOU EXPERIENCE PROBLEMS:
If you believe your p roduct is defective, p lease return it to the place where yo u bought it. Our Technical Team will gladly advise on any Eterna Lighting product, bu t may not be able to give specic instructions regarding individual installations.
For breakage inf ormation visit: www.eterna-lighting.co.uk
SSRCDMC
SSRCDWH
TWSRCDMC
TWSRCDWH
READ THIS FIRST:
Check the pack and m ake sure you have all of the parts liste d on the front of this bookle t. If not, contact the outlet where you bought this product.
This tting mus t be installed by a competent p erson in accordance with th e Building Regulations mak ing reference to the cu rrent edition of the IEE Wirin g Regulations (BS7671).
As the buyer, install er and/or user of this product it is your own respon sibility to ensure that this spur or socket is t f or the purpose for which you have intended it. Ete rna Lighting cannot accept any liability fo r loss, damage or premature fai lure resulting from inappropriate use.
Suitable for indoor use only.
Do not attach to su rfaces which are damp, fresh ly painted or other wise electricall y conductive (e.g. metallic sur faces).
Make connecti ons to the electrical supp ly in accordance with the f ollowing code:
Live - Brown or Red Neutral - Blue or B lack Earth - Gree n and Yellow
When making con nections, ensure that the te rminals are tightened se curely and that no strands of wi re protrude. Chec k that the terminals are tightene d onto the bared cond uctors and not onto any insulation.
This produc t must be connected to Ear th.
You are advised at ever y stage of your installatio n to double- check all electrical co nnections you have made. After you h ave completed your installatio n there are elec trical tests that should b e carried out: these tests are sp ecied in the Wiring Reg ulations (BS7671) referre d to in the Building Regulatio ns.
INSTALLATION:
SINGL E FUSED RCD SPUR
Connect the wi ring from the mains supply to the terminals marked “LINE”. See diagram oppo site.
Connect the wi ring from your appliance to the terminals marked “LOAD”. See diagram opp osite.
TWIN UNSWITCHED RCD SOCKET
Connect your ma ins supply wiring to the termina ls according to the colo ur code above. Note that earth connec tions may be made to either or b oth terminal(s) marked “E”. See diagram opposite.
OPERATION:
01. Restore the mains power (after in stallation).
02. Press the green reset b utton and check that the indicator window has turned red.
03. (For every use) Press th e TEST button.
04. Check that the indi cator window has turned white.
05. Press the reset butt on and use as a normal socket.
SPECIFICATION:
• Maximum operati ng load: 13A resistive, 3A
inductive.
• Mechanically latch ed (no need to reset after po wer
loss).
• Responsive to both po sitive and negative cycles .
• Trip speed less than 40 ms.
• 30mA trip current .
• RCD contact brea k: double pole.
NOTE: unit will trip if the li ve and neutral input is reversed and if n eutral and/or earth connec tions are lost. The unit w ill also react to pulsating ear th fault currents.
N
E
NL
L
N
L
E
LOAD
LINE
Brown (L)
Blue (N)
Yellow / Green (E)