READ THIS FIRST:
Check the pack and m ake sure you have all of the
parts liste d on the front of this bookle t. If not,
contact the outlet where you bought this product.
This produc t contains glass, care must be take n when
assembling, t ting or handling to prevent per sonal
injury or damag e to the product.
This light tting must be installed by a competent
person in accordance with the current building
and IEE wiring regulations.
As the buyer, install er and/or user of this product it
is your own responsi bility to ensure that this tt ing
is t for the purpo se for which you have intended
it. Eterna Lightin g cannot accept any liability fo r
loss, damage or premature failure resulting from
inappropriate use.
This product is designed and constructed according
to the principles of the appropriate British Standard.
Using this tting in an environment where there
is prolonged p eriods of use or higher than no rmal
ambient temper atures, may result in a shorten ed
working life.
Switch o the mains be fore commencing installati on
and remove the appro priate circuit fuse or lock o
MCB.
This unit is suitab le for outdoor use.
This produc t is suitable for installatio n on surfaces
with normal ammability e.g. wood, plasterboard
and masonry. It is not s uitable for use on highly
ammable sur faces (e.g. polystyren e, textiles).
Before makin g xing hole(s), check that there are no
obstructi ons hidden beneath the mount ing surface
such as pipes or cab les.
Make sure that the xi ngs are strong enough to
support the co nsiderable weight of the t ting and
hold it rigidly.
The lamp must be p ositioned so that there is at
least 1M (1000mm) between th e luminaire and any
illuminated sur face. Floodlights shoul d be positioned
well away from ammab le materials.
Do not attach to su rfaces which are damp, fresh ly
painted or otherwise electrically conductive
(e.g. metallic sur faces).
This produc t is designed for permanent co nnection
to xed wiring: this m ust be a suitable circuit
(protected w ith the appropriate MCB or fuse).
When making con nections ensure that the ter minals
are tightened se curely and that no strands of wi re
protrude. Chec k that the terminals are tightene d
onto the bared cond uctors and not onto any
insulation.
This product is double insulated. DO NOT CONNECT
ANY PART TO EARTH.
This produc t is not intended to be used by childr en
and persons wi th sensory, physical and/or ment al
impairments th at would prevent them from using i t
saf ely.
IMPORTANT - if the ex ternal exible cable of t his
luminaire is damag ed it shall be exclusively repl aced
by a qualied engi neer.
You are advised at ever y stage of your installatio n to
double-check any electrical connections you have
made. After you h ave completed your installatio n
there are elec trical tests that should b e carried out,
these tests are sp ecied in the current IEE wir ing and
building regulations.
Do not carr y or lift the ood light by the mains
supply cable.
LAMP REPLACEMENT:
This luminaire has a s ealed LED lamp and is
maintenance free , no lamp replacement is require d.
CLEANING:
Clean this light t ting only with a soft dr y cloth.
Do not use any chemic al or abrasive cleaners.
INSTALLATION:
1. Choos e the location for your new lig ht tting
giving considerations to the points listed opposite.
2. Isolate mains.
3. Usi ng the bracket, mark xing p oints and drill
xing holes, according to your chosen xing
method (Fixing s not included). See diagrams
opposite for marking measurements.
4. Terminate loose ends of wi re to an appropriate IP
rated junctio n box or similar, ensuring the Live and
Neutral polarities are observed.
Live - Brown / Red
Neutral - Blue / Bl ack
The oodlight is supplied pre-wired but also
has a 2-way termi nal block in the ho using.
5) I f wiring direct in to the tti ng re-t the terminal
block, tighte n the cable restraint clamp, ti ghten
the gland nut and re -t the cover.
6. Restore power an d test the luminaire.
7. Adjust oo dlight head towards the area to be
illuminated and lo ck o using two clamping bol ts.
Fixing slots on bracket
70mm
For All Floodlights
LN
Blue
(Power Cable)
Brown
(Power Cable)
Blue
(Power Cable)
Brown
(Power Cable)
Terminal Block
Power
Cable