Eterna POLY10, POLY30, POLY20 Installation Instructions Manual

These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION
AND RETAIN FOR FUTURE REFERENCE
Model:
POLY10 / POLY20 / POLY30
10W / 20W / 30W Polycarbonate LED Floodlights
INSTALLATION INSTRUCTIONS
Pack contents:
1 x LED oodlight complete with 2 core
1.0mm2 x 0.8m silicone cable and quick x mounting bracket
Issue 2015
HELPLINE:
• T: 01933 673 144
• F: 01933 678 083
• E: sales@eterna-lighting.co.uk
Visit our website:
www.eterna-lighting.co.uk
1M
Made in China
EVENTUALLY, YOU MAY WANT TO REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from Electrical and Electronic Equipment (European “WEEE Direc tive” eective August 20 05—UK WEEE Regulation s eective 2nd January 20 07). Environment Agenc y Registered Producer : WEE/ GA0248Q Z.
WHEN YOUR PR ODUCT COMES TO TH E END OF ITS LIFE OR YO U CHOOSE TO REPLACE I T, PLEA SE RECYCLE IT W HERE FACILITIES E XIST  DO NOT DISPOSE WITH HOUSEHOLD WASTE.
IF YOU EXPERIENCE PROBLEMS:
If you believe your p roduct is defective, p lease return it to the place where yo u bought it. Our Technical Team will gladly advise on any Eterna Lighting product, bu t may not be able to give specic instructions regarding individual installations.
LAMP SPECIFICATIONS:
10W 20W 30W
Lumens total ux
800 lm 2000 lm 3000 lm
Lumens 120° ux
750 lm 1870 lm 2800 lm
Rated Wattage 9.3W 19.9W 30W
Rated luminous ux 900 lm 2000 lm 3000 lm
Nominal life time of the lamp 25,000 hrs 25,000 hrs 25,000 hrs
Colour temperature 4000K 4000K 4000K
Number of switching cycles before premature lamp failure
15,000 15,000 15,000
Warm-up time up to 60 % of the full light output
Instant full light Instant full light Instant full light
Dimmable No No No
LED array dimensions (L/W) 42 x 22mm 60 x 30mm 77 x 33mm
Nominal beam angle 120° 120° 120°
Rated power 9.3W 19.9W 30W
Rated lamp lifetime 25,000 hrs 25,000 hrs 25,000 hrs
Lamp power factor >0.9 >0.9 >0.9
Lumen maintenance factor at end of nominal life
≥70% ≥70% ≥70%
Starting time <0.5s <0.5s <0.5s
Colour rendering >65 >65 >65
Colour consistency
Within 6 step
Macadam ellipse
Within 6 step
Macadam ellipse
Within 6 step
Macadam ellipse
Rated peak intensity 326cd 852cd 1300cd
Voltage 230V 230V 230V
Not suitable for accent lighting
10W
20W
30W
TRADE
PRODUCT:
ENERGY INFORMATION AVAILABLE ON
APPLICATION
READ THIS FIRST:
Check the pack and m ake sure you have all of the parts liste d on the front of this bookle t. If not, contact the outlet where you bought this product.
This produc t contains glass, care must be take n when assembling, t ting or handling to prevent per sonal injury or damag e to the product.
This light tting must be installed by a competent person in accordance with the current building and IEE wiring regulations.
As the buyer, install er and/or user of this product it is your own responsi bility to ensure that this tt ing is t for the purpo se for which you have intended it. Eterna Lightin g cannot accept any liability fo r loss, damage or premature failure resulting from inappropriate use.
This product is designed and constructed according to the principles of the appropriate British Standard. Using this tting in an environment where there is prolonged p eriods of use or higher than no rmal ambient temper atures, may result in a shorten ed working life.
Switch o the mains be fore commencing installati on and remove the appro priate circuit fuse or lock o MCB.
This unit is suitab le for outdoor use.
This produc t is suitable for installatio n on surfaces with normal ammability e.g. wood, plasterboard and masonry. It is not s uitable for use on highly ammable sur faces (e.g. polystyren e, textiles).
Before makin g xing hole(s), check that there are no obstructi ons hidden beneath the mount ing surface such as pipes or cab les.
Make sure that the xi ngs are strong enough to support the co nsiderable weight of the t ting and hold it rigidly.
The lamp must be p ositioned so that there is at least 1M (1000mm) between th e luminaire and any illuminated sur face. Floodlights shoul d be positioned well away from ammab le materials.
Do not attach to su rfaces which are damp, fresh ly painted or otherwise electrically conductive (e.g. metallic sur faces).
This produc t is designed for permanent co nnection to xed wiring: this m ust be a suitable circuit (protected w ith the appropriate MCB or fuse).
When making con nections ensure that the ter minals are tightened se curely and that no strands of wi re protrude. Chec k that the terminals are tightene d onto the bared cond uctors and not onto any insulation.
This product is double insulated. DO NOT CONNECT
ANY PART TO EARTH.
This produc t is not intended to be used by childr en and persons wi th sensory, physical and/or ment al impairments th at would prevent them from using i t saf ely.
IMPORTANT - if the ex ternal exible cable of t his luminaire is damag ed it shall be exclusively repl aced by a qualied engi neer.
You are advised at ever y stage of your installatio n to double-check any electrical connections you have made. After you h ave completed your installatio n there are elec trical tests that should b e carried out, these tests are sp ecied in the current IEE wir ing and building regulations.
Do not carr y or lift the ood light by the mains supply cable.
LAMP REPLACEMENT:
This luminaire has a s ealed LED lamp and is maintenance free , no lamp replacement is require d.
CLEANING:
Clean this light t ting only with a soft dr y cloth.
Do not use any chemic al or abrasive cleaners.
INSTALLATION:
1. Choos e the location for your new lig ht tting giving considerations to the points listed opposite.
2. Isolate mains.
3. Usi ng the bracket, mark xing p oints and drill xing holes, according to your chosen xing method (Fixing s not included). See diagrams opposite for marking measurements.
4. Terminate loose ends of wi re to an appropriate IP rated junctio n box or similar, ensuring the Live and Neutral polarities are observed.
Live - Brown / Red Neutral - Blue / Bl ack
The oodlight is supplied pre-wired but also has a 2-way termi nal block in the ho using.
5) I f wiring direct in to the tti ng re-t the terminal block, tighte n the cable restraint clamp, ti ghten the gland nut and re -t the cover.
6. Restore power an d test the luminaire.
7. Adjust oo dlight head towards the area to be illuminated and lo ck o using two clamping bol ts.
Fixing slots on bracket
70mm
For All Floodlights
LN
Blue (Power Cable)
Brown (Power Cable)
Blue (Power Cable)
Brown (Power Cable)
Terminal Block
Power
Cable