Eterna PIRF120BK, PIRF120WH, PIRF400BK, PIRF400WH Installation Instructions Manual

Issue 2013
HELPLINE:
• T: 01933 673 144
• F: 01933 678 083
• E: sales@eterna-lighting.co.uk
Visit our website:
www.eterna-lighting.co.uk
These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE USING YOUR NEW FITTING
PLEASE RETAIN FOR FUTURE REFERENCE
Model:
PIRF120BK / PIRF120WH / PIRF400BK / PIRF400WH
120W / 400W 180º PIR Halogen Floodlights
Pack contents:
1 x Floodlight 1 x Linear Halogen Lamp
INSTALLATION INSTRUCTIONS
A guide for qualied electricians
PI RF120 WH
PIRF400 BK
1M
EVENTUALLY, YOU MAY WANT TO REPL ACE THI S PRODUCT:
Regulations re quire the recycling of Waste fr om Electrical and Elec tronic Equipment (European “ WEEE Directive” e ective August 2005— UK WEEE Regulations eec tive 2nd January 2007). Environmen t Agency Registered Pro ducer: WEE/GA0248QZ.
WHEN YOUR PR ODUCT COMES TO TH E END OF ITS LIFE OR YOU CH OOSE TO REPLACE IT, PLEA SE RECYCLE IT WHERE FACILI TIES EXIST  DO N OT DISPOSE WITH HO USEHOLD WASTE.
IF YOU EXPERIENCE PROBLEMS:
If you believe your p roduct is defective, p lease return it to the place whe re you bought it. Our Technical Team will gladly adv ise on any Eterna Lighting produc t, but may not be able to give spe cic instructions rega rding individual installations.
874/2012
C
MODELNO.
PIRF Range
MODELNO.
A
++
XXX kWh/1000h
120
PIRF120BK / WH
C
MODELNO.
A
++
XXX kWh/1000h
400
PIRF400BK / WH
C
Fig 1
Avoid nuisance / false t riggering by directing s ensor away from:
• Trees and shrubs
• Reective su rfaces such as smooth white w alls
• Swimming pools
• Heat sources such as b oiler ues
The PIR sensor sc anning specications (approximately 12 metres at 180°) may v ary slightly depending on the mounting height and location.
The detecti on range of the unit may also alter w ith temperature cha nge. Before selectin g a place to install your PIR o odlight you should note that movement across the s can area is more eective than movement dire ctly towards or away from the sensor. (Refer g.2).
If movement is made w alking directly towards o r away from the senso r and not across the sensor the apparent dete ction range will be subs tantially reduced (refer g . 3).
Fig 3
INTRODUCTION:
The oodlight i ncorporates a PIR (Passive Infra R ed) sensing device wh ich continuously scans a prese t operating zon e and immediately switches th e light on when it detec ts movement in that area.
This means that whe never movement is detecte d within the range o f the sensor the light will switch on automaticall y to illuminate the area you have selected to l ight. While there is movement wi thin range of the unit th e light will remain on.
READ THIS FIRST:
Check the pack and m ake sure you have all of the parts liste d on the front of this bookle t. If not, contact the outlet where you bought this product.
This produc t contains glass, care must be take n when assembling, t ting or handling to prevent per sonal injury or damag e to the product.
This produc t must be installed by a compet ent person in accord ance with the current building a nd IEE wiring regulations.
As the buyer, install er and/or user of this product it is your own responsi bility to ensure that this tt ing is t for the purpo se for which you have intended it. Eterna Lightin g cannot accept any liability fo r loss, damage or premature failure resulting from inappropriate use.
This product is designed and constructed according to the principles o f the appropriate British Stan dard and is intended fo r normal domestic ser vice. Using this tting in any oth er environments may result in a shortened working life.
Switch o the mains be fore commencing installati on and remove the appro priate circuit fuse or lock o MCB.
When replacin g the lamp, do not touch with bare ngers, grip th e lamp with a tissue or clean sof t cloth.
This unit is suitab le for outdoor use.
This produc t is designed for permanent co nnection to xed wiring: this m ust be a suitable circuit (protected w ith the appropriate MCB or fuse).
Before makin g xing hole(s), check that there are no obstructi ons hidden beneath the mount ing surface such as pipes or cab les.
Make sure that the xi ngs are strong enough to support the co nsiderable weight of the t ting and hold it rigidly.
The lamp must be p ositioned so that there is at lea st 1M between the bulb an d any illuminated surface.
When making con nections ensure that the ter minals are tightened se curely and that no strands of wire p rotrude. Check that the termin als are tightened onto the b ared conductors and not o nto any insulation.
This produc t must be connected to ear th termination.
WARNING: This product becomes hot!
This produc t is not intended to be used by childr en and persons wi th sensory, physical and/or ment al impairments th at would prevent them from using i t saf ely.
IMPORTANT - Always s witch o the mains p ower before changing the lamp.
You are advised at ever y stage of your installatio n to double-check any electrical connections you have made. After you h ave completed your installatio n there are elec trical tests that should b e carried out, these tests are sp ecied in the current IEE wir ing and building regulations.
CLEANING:
• To avoid dust build-up and ensur e proper functionin g of the oodlight, please w ipe the sensor lens light ly with a damp cloth every 3 months.
• Disconnect the po wer and clean the exterior o nly of this tting wit h a moist (not wet) cloth.
• Do not use any chemic al or abrasive cleaners.
WHERE TO F IT YOUR PIR FLOODLIGHT:
To achieve best results we su ggest you take the following points into consideration:
Do not mount on a sur face that has vibration.
Ideally the PIR o od light should be mounted 1.8 to
2.5 metres (6 to 8f t) above the area to be scanned
(refer to g.1 below).
To avoid damage to the unit do not ai m sensor towards sun.
Avoid positioning th e sensor unit adjacent to a bright light source w hich may prevent the unit from operating whe n the lux control is set to operate i n dark conditions.
Yellow/Green (Power Cable)
Blue / White (Power Cable)
Brown (Power Cable)
White (Lamp Wire)
Yellow / Green
(power cable)
2.5M
4M 8M 12M
180˚
Appr.
Eective
Less
Eective
Fig 2
INSTALLATION:
LN
Yellow/Green (Power Cable)
Blue / White (Power Cable)
Brown (Power Cable)
Yellow/Green (Earth)
Blue (Power Cable)
Brown (Power Cable)
RED (PIR Switch Wire)
White (Lamp Wire)
Terminal Block
Power Cable
L N
Brown (power cable)
Blue (power cable)
Yellow / Green
(power cable)
Lamp Cover Screw
Cable Gland
Wall Mounting
Support Screws
Wall Mounting
Support Bracket
Junction Box
Locking Nut
Fig 4