874/2012
MODELNO.
PERLED20
EVENTUALLY, YOU MAY WANT TO REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from Electrical and Electronic Equipment (European “WEEE Direc tive” eective August 20 05—UK WEEE Regulation s eective 2nd January 20 07). Environment Agenc y Registered Producer : WEE/ GA0248Q Z.
WHEN YOUR PR ODUCT COMES TO TH E END OF ITS LIFE OR YO U CHOOSE TO REPLACE I T, PLEA SE RECYCLE IT W HERE FACILITIES E XIST  DO NOT DISPOSE WITH HOUSEHOLD WASTE.
CLEANING:
Disconnect t he power and clean the exte rior only of this tting wit h a moist (not wet) cloth.
Do not use any chemic al or abrasive cleaners.
IF YOU EXPERIENCE PROBLEMS:
If you believe your p roduct is defective, p lease return it to the place where yo u bought it. Our Technical Team will gladly advise on any Eterna Lighting product, bu t may not be able to give specic instructions regarding individual installations.
Pack contents:
20W perimeter LED li ght with IP rated wiring con nection box and wall mounting b racket
LAMP SPECIFICATIONS:
Lumens total ux
1800 lm
Rated Wattage 20W
Rated luminous ux 1800 lm
Nominal life time of the lamp 25,000 hrs
Colour temperature 3000K
Number of switching cycles before premature lamp failure
20,000
Warm-up time up to 60 % of the full light output
Instant full light
Dimmable No
LED strip dimensions (L/W) 270 x 60mm
Nominal beam angle 160°
Rated power 20W
Rated lamp lifetime 25,000 hrs
Lamp power factor 0.85
Lumen maintenance factor at end of nominal life
70%
Starting time <0.5s
Colour rendering >80
Colour consistency
Within 6 step
Macadam ellipse
Rated peak intensity 540cd
Rated beam angle 160°
Voltage 240V
Email: sales@eterna-lighting.co.uk / technical@eterna-lighting.co.uk
Visit our website: www.eterna-lighting.co.uk
Made in ChinaIssue 1016
READ THIS FIRST:
Check the pack and m ake sure you have all of the parts liste d on the front of this bookle t. If not, contact the outlet where you bought this product.
This produc t must be installed by a compet ent person in accord ance with the current building a nd IEE wiring regulations.
As the buyer, install er and/or user of this product it is your own responsi bility to ensure that this tt ing is t for the purpo se for which you have intended it. Eterna Lightin g cannot accept any liability fo r loss, damage or premature failure resulting from inappropriate use.
This product is designed and constructed according to the principles o f the appropriate British Stan dard and is intended fo r normal service. Using this  tting in any other environm ents may result in a shortene d working life, for example where there is prolonged periods of use.
Switch o the mains be fore commencing installati on and remove the appro priate circuit fuse or lock o MCB.
This unit is suitab le for outdoor use.
This produc t is designed for permanent co nnection to xed wiring: this m ust be a suitable circuit (protected w ith the appropriate MCB or fuse).
This produc t is suitable for installatio n on surfaces with normal ammability e.g. wood, plasterboard and masonry.
Before makin g xing hole(s), check that there are no obstructi ons hidden beneath the mount ing surface such as pipes or cab les.
Make sure that the xi ngs are strong enough to support the co nsiderable weight of the t ting and hold it rigidly.
The lamp must be p ositioned so that there is at lea st
0.5m (500mm) bet ween the bulb and any illuminated surface.
When choosing th e location for your new tt ing, ensure that the xin gs will be anchored in a solid surface e.g. con crete, brick or a joist—do not  x directly onto panelling, cladding, plasterboard etc.
Do not attach to su rfaces which are damp, fresh ly painted or other wise electricall y conductive (e.g. metallic sur faces).
When making con nections ensure that the ter minals are tightened se curely and that no strands of wi re protrude. Chec k that the terminals are tightene d onto the bared cond uctors and not onto any insulation.
This tting is d ouble insulated; do not connec t any part to eart h.
This produc t is not intended to be used by childr en and persons wi th sensory, physical and/or ment al impairments th at would prevent them from using i t saf ely.
You are advised at ever y stage of your installatio n to double-check any electrical connections you have made. After you h ave completed your installatio n there are elec trical tests that should b e carried out, these tests are sp ecied in the current IEE wir ing and building regulations.
IMPORTANT:
PERLED20 PHOTOCELL - Do not inst all under
eaves or in a location o f frequent shadow that will prevent the light fro m switching o when require d. Do not install ne ar other sources of bright light tha t will prevent the light f rom switching on when the ambient light leve l falls.
DO NOT CAR RY OR LIFT THE PERI METER LIGHT BY THE MAINS SUPPLY CABLE!
PLEASE NOTE:
THE PHOTOCELL OPE RATES IN NATURAL LIGHT, THIS SH OULD NOT BE TESTED USING ARTIFICIAL LIGHT (LE D, ENERGY SAVING LAM P ETC).
LAMP REPLACEMENT:
INSTALLATION:
1. Choose the location f or your new light tting giving considerations to the points listed opposite and take account of mou nting height for area to be lit.
2. Isolate mains.
3. Mark xing poin ts by using the xing bracket as a template and drill  xing holes, according to your chosen xing method.
4. Make connecti ons in the IP65 rated connectio n box, ensuring th e Live, and Neutral polariti es are observed.
5A) Connect blue wir e to Neutral terminal marked
(N).
5B) Connect brown wi re to live terminal marked (L)
(light to stay on contin uously) or connect brown cable to terminal m arked LI (if you want photocell operation).
6. Restore power a nd test the luminaire.
Connection Box
Connect BLUE wire to (N)
N
STEP 5A
Connection Box
Connect BROWN wire to (L)
L
STEP 5B
CONTINUOUS LIGHT OPTION
Connection Box
Connect BROWN wire to (LI)
LI
STEP 5B
PHOTOCELL OPTION
Based On Maintenance Factor 0.8
PERLED20 Illuminance Area
0
0m
5m
3m
4.5m
8.5m
7.5 10 15 20 30
Illuminance (Lux)
EXAMPLE FOR MEDIUM TRAFFIC PARKING AREAS
>=10 LUX AVERAGE
Oce buildings • Plants • Sports & Multipurpose Building Complexes
3m
high
4.25m
4.25m
The light source cont ained in this luminaire shall only be rep laced by the manufacturer, service age nt or a similar qualied pers on.
CAUTION, RISK OF ELECTRIC SHOCK.
The light source is designed to last the lifetime of the luminaire.
Loading...