Eterna MODERNOBK, MODPIRBK, MODERNOWH, MODPIRWH Installation Instructions And Operators Manual

Model:
MODERNOBK / MODERNOWH
MODPIRBK / MODPIRWH
6W LED Lantern / 6W LED Lantern With PIR
These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION
AND RETAIN FOR FUTURE REFERENCE
A guide for qualied electricians
874/2012
MODELNO.
MODERNO RANGE
EVENTUALLY, YOU MAY WANT TO REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from Electrical and Electronic Equipment (European “WEEE Direc tive” eective August 20 05—UK WEEE Regulation s eective 2nd January 20 07). Environment Agenc y Registered Producer : WEE/ GA0248Q Z.
WHEN YOUR PR ODUCT COMES TO TH E END OF ITS LIFE OR YO U CHOOSE TO REPLACE I T, PLEASE RECYCLE IT W HERE FACILITIES E XIST  DO NOT DISPOSE WITH HOUSEHOLD WASTE.
CLEANING:
Disconnect t he power and clean the exte rior only of this tting wit h a moist (not wet) cloth.
Do not use any chemic al or abrasive cleaners.
IF YOU EXPERIENCE PROBLEMS:
If you believe your p roduct is defective, p lease return it to the place where yo u bought it. Our Technical Team will gladly advise on any Eterna Lighting product, bu t may not be able to give specic instructions regarding individual installations.
Email: sales@eterna-lighting.co.uk / technical@eterna-lighting.co.uk
Visit our website: www.eterna-lighting.co.uk
Made in ChinaIssue 1116
PG 6 PG 1
Pack contents:
1 x LED lantern
LED LAM P SPECIFICATIONS:
Lumens total ux
330 lm
Lumens 120° ux
300 lm
Rated Wattage 6W
Rated luminous ux 300 lm
Nominal life time of the lamp 35,000 hrs
Colour temperature 3100K
Number of switching cycles before premature lamp failure
≥15,000
Warm-up time up to 60 % of the full light output
Instant full light
Dimmable No
LED array dimensions (Ø) 65mm
Nominal beam angle 120°
Rated power 6W
Rated lamp lifetime 35,000 hrs
Lamp power factor >0.5
Lumen maintenance factor at end of nominal life
≥0.70
Starting time <0.1s
Colour rendering ≥80
Colour consistency
Within 6 step
Macadam ellipse
Rated peak intensity 120cd
Rated beam angle 120°
Voltage 240V
Not suitable for accent lighting
PG 2 PG 3
READ THIS FIRST:
Check the pack and m ake sure you have all of the parts liste d on the front of this bookle t. If not, contact the outlet where you bought this product.
This produc t must be installed by a compet ent person in accord ance with the current building a nd IEE wiring regulations.
As the buyer, install er and/or user of this product it is your own responsi bility to ensure that this tt ing is t for the purpo se for which you have intended it. Eterna Lightin g cannot accept any liability fo r loss, damage or premature failure resulting from inappropriate use.
This product is designed and constructed according to the principles o f the appropriate British Stan dard and is intended fo r normal domestic ser vice. Using this tting in any oth er environments may result in a shortened w orking life, for example w here there is prolonged p eriods of use or higher than no rmal ambient temper atures such as lighting public or shared spaces.
Switch o the mains be fore commencing installati on and remove the appro priate circuit fuse or lock o MCB.
This unit is suitab le for outdoor use.
This produc t is suitable for installatio n on surfaces with normal ammability e.g. wood, plasterboard and masonry. It is not s uitable for use on highly ammable surfaces
Before makin g xing hole(s), check that there are no obstructi ons hidden beneath the mount ing surface such as pipes or cab les.
Make sure that the xi ngs are strong enough to support the co nsiderable weight of the t ting and hold it rigidly.
The chosen loc ation of your new tting shou ld allow for the produc t to be securely mounted. An d safely connected to th e mains supply (lighting circuit).
When choosing th e location for your new tt ing, ensure that the xin gs will be anchored in a solid surface e.g. con crete, brick or a joist—do not  x directly onto panelling, cladding, plasterboard etc.
When making con nections ensure that the ter minals are tightened se curely and that no strands of wi re protrude. Chec k that the terminals are tightene d onto the bared cond uctors and not onto any insulation.
This tting is d ouble insulated; do not connec t any part to eart h.
This produc t is not intended to be used by childr en and persons wi th sensory, physical and/or ment al impairments th at would prevent them from using i t saf ely.
You are advised at ever y stage of your installatio n to double-check any electrical connections you have made. After you h ave completed your installatio n there are elec trical tests that should b e carried out, these tests are sp ecied in the current IEE wir ing and building regulations.
INSTALLATION:
ISOLATE MAINS BEFORE CARRYING OUT INSTALLATION
01) Undo the nuts each s ide at the front of the tting and lift o the f ront section of the lanter n
02) Using the b ack cover of the tting as a template, mark the locati on of the xing holes.
03) Pierce the r ubber grommet in the back of th e tting. Make th e hole as small as possible so that a good watert ight seal is maintained when th e cable has been threaded through.
04) Th read the cable through the gro mmet.
05) Sec ure the tting to the wall using  xings (not supplie d).
06) Make t he connections to the termi nal block according to the colo ur code and symbols:
LIVE - Brown or Red • NEUTRAL - Bl ue or Black
07) Conne ct the two wires from the f ront half of the lantern to the push ter minal block in line with the colour code and s ymbols (see g. 4 opposite).
08) Re place the front part of lanter n and secure by tightening the t wo nuts making sure you have a rubber sealin g washer under both nuts.
09) Res tore power.
10) Switch on and product should function.
SPECIFICATIONS:
• Det ection range: Approx. 120° (hor izontal), Max. 8
metres.
• Duration time: f rom 5 sec - 5 mins. (adjustable).
• No over ride facility.
• LUX - adjustable.
LAMP REPLACEMENT:
WHERE TO F IT YOUR PIR FU LL LANTERN:
To achieve best results we su ggest you take the following points into consideration:
Do not mount on a sur face that has vibration.
Ideally the PIR lante rn should be mounted 1.8 to 2.5 metres (6 to 8ft) ab ove the area to be scanned (refer to Fig. 1 below).
To avoid damage to the unit do not ai m sensor towards the sun.
Avoid positioning th e sensor unit adjacent to a bright light source w hich may prevent the unit from operating whe n the lux control is set to operate i n dark conditions.
Avoid nuisance false t riggering by directing s ensor away from:
Trees and shrubs Reective su rfaces such as smooth white w alls Swimming pools Heat sources such as b oiler ues
The PIR sensor sc anning specications (approximately 8 met res at 120°) may vary slightly depending on the mounting height and location.
The detecti on range of the unit may also alter with temperatu re change. Before selec ting a place to install your PIR lant ern you should note that movement across the s can area is more eective than movement dire ctly towards or away from the sensor (refer to Fig. 2 a bove).
If movement is made w alking directly towards o r away from the senso r and not across the apparent detection r ange will be substantially re duced (refer to Fig. 3 above).
1.8-
2.5M
4M 8M
120˚
Approx
Fig 1
EFFECTIVE:
Movement across scan area
LESS EFFECTIVE:
Movement directly in front of scan area
Fig 2
Fig 3
L N
Blue (Power Cable)
Brown
(Power Cable) Blue (Power Cable)
Brown (Power Cable)
Fig 4
The light source cont ained in this luminaire shall only be rep laced by the manufacturer, service age nt or a similar qualied pers on.
CAUTION, RISK OF ELECTRIC SHOCK.
The light source is designed to last the lifetime of the luminaire.
Loading...