READ THIS FIRST:
Check the pack and m ake sure you have all of the
parts liste d on the front of this bookle t. If not,
contact the outlet where you bought this product.
This produc t must be installed by a compet ent
person in accord ance with the current building a nd
IEE wiring regulations.
As the buyer, install er and/or user of this product it
is your own responsi bility to ensure that this tt ing
is t for the purpo se for which you have intended
it. Eterna Lightin g cannot accept any liability fo r
loss, damage or premature failure resulting from
inappropriate use.
This product is designed and constructed according
to the principles o f the appropriate British Stan dard
and is intended fo r normal domestic ser vice.
The lifetime of co mpact uorescent lamps an d
ballasts are ne gatively aected by incr eased
switching i.e. wh ere a PIR is being used to control the
tting.
This light ttin g must be installed in accorda nce with
the Building Re gulations. These may be obta ined
from HMSO or viewed and downloaded from www.
communities.go v.uk following the link for Building
Regulations.
Switch o the mains be fore commencing installati on
and remove the appropriate circuit fuse.
Suitable for outdoor use.
This produc t is suitable for installatio n on surfaces
with normal ammability, e.g. wood, plasterboard,
masonry. It is not sui table for use on highly
ammable sur faces (e.g. polystyren e, textiles).
Before makin g xing hole(s), check that there are no
obstructi ons hidden beneath the mount ing surface
such as pipes or cab les.
The chosen loc ation of your new tting shou ld allow
for the produc t to be securely mounted and s afely
connected to th e mains supply (lighting circuit).
If the location o f your new tting requires th e
provision of a new el ectrical supply, the suppl y
must conform with the requirements of the Building
Regulations.
This produc t is designed for permanent co nnection
to xed wiring: this s hould be either a suitable
lighting circuit (p rotected with a 5 or 6 Amp MCB or
fuse) or a fused spu r (with a 3 Amp fuse) via a fused
connection u nit. We recommend that the suppl y
incorporates a s witch for ease of operation .
Make connecti ons to the electrical supp ly in
accordance with the f ollowing code:
Live - Brown or Red
Neutral - Blue or B lack
This tting is d ouble insulated, do not connec t any
part to eart h.
You are advised at ever y stage of your installatio n to
double-check any electrical connections you have
made. After you h ave completed your installatio n
there are elec trical tests that should b e carried out:
these tests are sp ecied in the Wiring Reg ulations
(BS7671) refer red to in the Building Regulati ons.
INSTALLATION:
01) Undo the screws at the top and bot tom of the
tting and lif t o the front.
02) Undo the screw in the plas tic cover at the bottom
of the lamphold er and prize o the cover.
03) Using the back of the tt ing as a template, mark
the location of t he xing holes.
04) Pierce the rubbe r grommet in the back of the
tting. Make th e hole as small as possible so that
a good watert ight seal is maintained when th e
cable has been threaded through.
05) Thread the cabl e through the grommet.
06) Secure the t ting to the wall using xings
(supplied). If the x ings supplied with your t ting
are not appropriate to your installation, select
suitable alternatives.
07) Make the connecti ons to the lampholder
according to the colour code.
08) Replace the cover on th e bottom of the
lampholder and tighten the screw.
09) Insert suita ble ES energy saving lamp.
10) Replace the front of the t ting and tighten the
screws.
11) Restor e the power and switch on.