READ THIS FIRST:
Check the pack and m ake sure you have all of the
parts liste d on the front of this bookle t. If not,
contact the outlet where you bought this product.
This light tting must be installed by a competent
person in accordance with the current building
and IEE wiring regulations.
As the buyer, install er and/or user of this product it
is your own responsi bility to ensure that this tt ing
is t for the purpo se for which you have intended
it. Eterna Lightin g cannot accept any liability fo r
loss, damage or premature failure resulting from
inappropriate use.
This product is designed and constructed according
to the principles of the appropriate British Standard.
Switch o the mains be fore commencing installati on
and remove the appro priate circuit fuse or lock o
MCB.
This unit is suitab le for outdoor use.
This produc t is suitable for installatio n on surfaces
with normal ammability e.g. wood, plasterboard
and masonry. It is not s uitable for use on highly
ammable sur faces (e.g. polystyren e, textiles).
Before makin g xing hole(s), check that there are no
obstructi ons hidden beneath the mount ing surface
such as pipes or cab les.
Make sure that the xi ngs are strong enough to
support the co nsiderable weight of the t ting and
hold it rigidly.
The lamp must be p ositioned so that there is at lea st
1m between the bulb an d any illuminated surface.
Floodlights sh ould be positioned well away f rom
ammable materials.
Do not attach to su rfaces which are damp, fresh ly
painted or otherwise electrically conductive
(e.g. metallic sur faces).
This produc t is designed for permanent co nnection
to xed wiring: this m ust be a suitable circuit
(protected w ith the appropriate MCB or fuse).
When making con nections ensure that the ter minals
are tightened se curely and that no strands of wi re
protrude. Chec k that the terminals are tightene d
onto the bared cond uctors and not onto any
insulation.
This produc t must be connected to an ear th
termination.
This produc t is not intended to be used by childr en
and persons wi th sensory, physical and/or ment al
impairments th at would prevent them from using i t
saf ely.
IMPORTANT - if the ex ternal exible cable of t his
luminaire is damag ed it should be exclusively
replaced by a quali ed engineer.
You are advised at ever y stage of your installatio n to
double-check any electrical connections you have
made. After you h ave completed your installatio n
there are elec trical tests that should b e carried out,
these tests are sp ecied in the current IEE wir ing and
building regul ations. If in doubt, consult a qual ied
electrician.
Do not carr y or lift the ood light by the mains
supply cable.
LAMP REPLACEMENT:
CLEANING:
Clean this light t ting only with a soft dr y cloth.
Do not use any chemic al or abrasive cleaners.
INSTALLATION:
1. Choose the location f or your new light tting
giving considerations to the points listed opposite.
2. Isolate mains.
3. Using the bracket, m ark xing points and drill
xing holes, according to your chosen xing
method (xings n ot included). See diagram
opposite for marking measurements.
4. Terminate loose ends of wi re to an appropriate IP
rated junctio n box or similar, ensuring the Live,
Earth and Neutral polarities are observed.
Live - Brown / Red
Neutral - Blue / Bl ack
Earth - Yellow / Green
5. Restore power and te st the luminaire.
6. Adjust oodli ght head towards the area to be
illuminated and secure in place.
EVENTUALLY, YOU MAY WANT TO
REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from
Electrical and Electronic Equipment (European
“WEEE Direc tive” eective August 20 05—UK
WEEE Regulation s eective 2nd January 20 07).
Environment Agenc y Registered Producer : WEE/
GA0248Q Z.
WHEN YOUR PR ODUCT COMES TO TH E END OF
ITS LIFE OR YO U CHOOSE TO REPLACE I T, PLEA SE
RECYCLE IT W HERE FACILITIES E XIST DO NOT
DISPOSE WITH HOUSEHOLD WASTE.
IF YOU EXPERIENCE PROBLEMS:
If you believe your p roduct is defective, p lease return
it to the place where yo u bought it. Our Technical
Team will gladly advise on any Eterna Lighting
product, bu t may not be able to give specic
instructions regarding individual installations.
102mm
103mm
FIXING S LOTS ON BRACKET
FIXING S LOTS ON BRACKET
FLOOD50
FLOOD80
88mm
310m m
FIXING S LOTS ON BRACKET
FLOOD120
FLOOD200
The light source cont ained in this luminaire
shall only be rep laced by the manufacturer,
service age nt or a similar qualied pers on.
CAUTION, RISK OF ELECTRIC SHOCK.
The light source is designed to last the lifetime of the
luminaire.
FIXING S LOTS ON BRACKET