READ THIS FIRST:
Check the pack and m ake sure you have all of the
parts liste d on the front of this bookle t. If not,
contact the outlet where you bought this product.
This produc t contains glass, care must be take n when
assembling, t ting or handling to prevent per sonal
injury or damag e to the product.
This light ttin g must be installed by a compe tent
person in accord ance with the Building Regulat ions
making refere nce to the current edition of the
IEE Wiring Regu lations (BS7671). The Buildin g
Regulations may b e obtained from HMSO or view ed
and downloaded from www.communities.gov.uk
following the lin k for Building Regulations .
As the buyer, install er and/or user of this product it
is your own responsi bility to ensure that this tt ing
is t for the purpo se for which you have intended
it. Eterna Lightin g cannot accept any liability fo r
loss, damage or premature failure resulting from
inappropriate use.
The lamps (bulbs/tubes) supplied with this tting are
consumable par ts and therefore may be out side of
any warranty oered.
Switch o the mains be fore commencing installati on
and remove the appropriate circuit fuse.
When working at h eights, please use a suita ble
platform.
Disconnect t he tting from the elec trical supply
before ash or hi gh voltage testing.
Suitable for indoor and outdoor use.
This produc t is suitable for installatio n on surfaces
with normal ammability e.g. wood, plasterboard,
and masonry. It is not s uitable for use on highly
ammable sur faces (e.g. polystyren e, textiles).
Before makin g xing hole(s), check that there are no
obstructi ons hidden beneath the mount ing surface
such as pipes or cab les.
The chosen loc ation of your new tting shou ld allow
for the produc t to be securely mounted and s afely
connected to th e mains supply (lighting circuit).
When choosing th e location for your new tt ing,
ensure that the xin gs will be anchored in a solid
surface e.g. con crete, brick or a joist—do not x
directly onto panelling, cladding, plasterboard etc.
If the location o f your new tting requires th e
provision of a new el ectrical supply, the suppl y
must conform with the requirements of the Building
Regulations mak ing reference to the current e dition
of the IEE Wiring Re gulations (BS7671).
This produc t is designed for permanent co nnection
to xed wiring: this s hould be either a suitable
lighting circuit (p rotected with a 5 or 6 Amp MCB or
fuse) or a fused spu r (with a 3 Amp fuse) via a fused
connection unit.
We recommend that the s upply incorporates a
switch for ease of o peration.
Make connecti ons to the electrical supp ly in
accordance with the f ollowing code:
Live - Brown or Red
Neutral - Blue or B lack
Earth - Gree n and Yellow
When making con nections, ensure that the te rminals
are tightened se curely and that no strands of wi re
protrude. Chec k that the terminals are tightene d
onto the bared cond uctors and not onto any
insulation.
This produc t must be connected to Ear th.
IMPORTANT: Always switch o at the mains before
changing the lamp.
You are advised at ever y stage of your installatio n to
double-check any electrical connections you have
made. After you h ave completed your installatio n
there are elec trical tests that should b e carried out:
these tests are sp ecied in the Wiring Reg ulations
(BS7671) refer red to in the Building Regulati ons.
INSTALLATION:
01. Choose the location for yo ur new oodlight
giving consideration to all of the conditions listed
above.
02. Using the xing str ap as a template, mark the
position for the xing holes on your mounting
surface.
03. Prepare your mounti ng surface as appropriate fo r
your chosen xin gs (not supplied). Use a spirit
level to ensure the t ting will be level.
04. Secure the tting in place.
05. Loosen the bolt s at each end of the xing strap
and adjust the ang le of your oodlight to give the
desired spread of light.
06. Tighten the b olts to lock your oodlight i n
position.
07. Make the connections to your mains su pply as
described in th e “Read this rst” sec tion.
08. Using a cross-h eaded screwdriver, undo the
screws that secur e the diuser and allow to hang
down.
09. Fit the uorescent la mp.
10. Replace the diuser a nd tighten the screws
making sure that the wat erproof gasket is
correctly positioned and compressed.
11. Press the trim back o nto the front of the tting
making sure the sl ots used for removal are at the
bottom.
12. Restore the power and s witch on.
LAMP REPLACEMENT:
01. Switch o the electricit y at the mains.
02. Us ing a cross-headed screwdr iver, undo the
screws that secur e the diuser and allow to hang
down.
03. Remove the lamp.
04. Insert new lamp.
05. R eplace the diuser and sec ure in position
making sure that th e gasket is correctly
positioned and compressed.
06. Restore th e power and switch on.
REPLACEMENT LAMP TYPE:
Fitting requi res 1 x 23W ES helical CFLi 6400K
(included) or energy saving alternative.
Fitting is rated a t 23W max.