Eterna D033, D034 Installation Instructions

Page 1
Cleaning:
> Clean this product only with a soft dry cloth > Do not use any chemical or abrasive cleaners.
Eventually, you may want to replace this transformer:
When your light fitting comes to the end of it’s life or you choose to update or upgrade it by replacing it, please do not dispose of it with your normal household waste, please recycle where facilities exist. When you need to dispose of this fitting, check with your retailer or local authority for suitable options. New regulations will encourage the recycling of Waste from Electrical and Electronic Equipment ( European “WEEE Directive” effective August 2005 ).
35—105W Electronic
step down transformer.
Model(s)
D033, D034
Pack contents:
D033 D034
Electronic transformer complete with: Electronic transformer complete with:
If you experience problems:
If your transformer is defective or develops a fault, please return it to the place where you bought it. You can call our Helpline for advice. The Helpline will gladly give advice on any aspect of any Eterna Lighting product but may not be able to give specific instructions regarding individual installations.
If in doubt, consult a qualified electrician.
Help line:
Tel: 01933 673 144 Fax: 01933 678 083 Email: sales@eterna-lighting.co.uk
For answers to frequently asked questions ( FAQs ) and other information visit our web-site www.eterna-lighting.co.uk
Mini-Amp socket box, Mini-Amp socket box,
Eterna ® Link&Light mains lead. 2m flexible mains lead ( not terminated ).
PLEASE READ THESE INSTRUCTIONS BEFORE
INSTALLING YOUR NEW FITTING
- -
PLEASE RETAIN FOR FUTURE REFERENCE
Page 2
Read this first:
> If in any doubt, consult a qualified
electrician.
> Suitable for indoor use only. > This product is only suitable for use in living
areas ( not for areas constantly subject to moisture ).
> This product is suitable for installation on
surfaces with normal flammability ( indicated by the "F" in a triangle ) e.g. wood, plasterboard, masonry. It is not suitable for use on highly flammable surfaces ( e.g. polystyrene, textiles ).
> Do not overload the transformer, check that
the total Wattage of all fittings does not exceed the maximum marked on the transformer.
> If the location of your new transformer requires
the provision of a new electrical supply, the supply must conform with the requirements of the latest edition of the IEE wiring regulations.
> Do not cover the transformer with any
insulating materials.
> Switch off the mains before commencing
installation and remove the appropriate circuit fuse.
> Make connections to the electrical supply in
accordance with the following code: Live - Brown or Red Neutral - Blue or Black Additional red wires may be present in your ceiling
that are connected to the ring live circuit. Do
not connect your transformer to these wires. If
these wires are not terminated in a ceiling
rose, join them together in a separate
terminal block ( not supplied ), ensure that
there are no strands of wire protruding from
the terminals and wrap well with insulating
tape.
> This product is designed for permanent
connection to fixed wiring: this should be either
a suitable lighting circuit ( protected with a 5 or
6 Amp MCB or fuse ) or a fused spur ( with a 3
Safety markings:
115°C
Amp fuse ) via a fused connection unit. We recommend that the supply incorporates a switch for ease of operation.
> This transformer is double insulated, do not
connect any part to earth.
> Do not connect to a circuit which also has
inductive loads connected as spikes generated switching inductive loads may damage electronic components within your transformer.
> Ensure that the transformer will be accessible
after installation for maintenance or replacement.
> The transformer should be placed where it
cannot be splashed.
> Do not install on surfaces which are damp,
freshly painted or otherwise electrically conductive (e.g. metallic surfaces).
> The transformer should be installed in a
ventilated area free from sources of heat.
> Important ! Disconnect from mains before
High Voltage testing. Do not flash test this product.
> This electronic transformer will shut off the
load automatically in the case of short circuit and overload. After removing the cause of the short circuit or overload, the Low Voltage supply will be restored.
> In the event that the transformer overheats, the
low voltage supply will be cut off by the operation of a thermal fuse to prevent further damage. The thermal fuse will be reset once the transformer has cooled down.
> It is recommended that this product be used
with Low Voltage compatible dimmers such as:- Varilight Intelligent, Home Automation Low Voltage and MK Intelligent Dimmer Switch.
> Always allow good ventilation around fitting
and transformer.
> When installing intumescent downlight covers,
do not place the transformer inside the fire hood.
> If in any doubt, consult a qualified
electrician.
For use with SELV ( Safety Extra Low Voltage ) light fittings
Typical installation:
> Choose the location for your transformer. Note
the conditions listed opposite.
> Switch off the power at the mains and remove
the appropriate circuit fuse.
> We recommend the use of Eterna Lighting Low
Voltage light fittings with this transformer.
with Eterna ® Link&Light mains lead or D034 with fitted mains lead ), ensure that connections are made according to the colour code opposite. Ensure also that there are no strands of wire protruding from the terminal block after making your connections block and wrap it well with insulating tape.
> Connect your low voltage light fittings > Restore the power and switch on.
Eterna lighting fittings have plugs fitted that are designed to plug directly into the socket block fitted to this transformer.
> Connect this transformer to the mains using
either ( D033 ) an Eterna ® Link&Light mains lead ( not supplied ) or ( D034 ) by connecting directly to your lighting circuit—see opposite.
> If you are using a terminal block ( either D033
Typical installation
Always ensure that cables are kept away from heat
Junction box
LV
Mains
300mm dia. Minimum clear area around fitting
Transformer ratings
Primary Voltage ( Mains in ) 240Volts 50Hz AC
Primary running current 0.46 Amps
Low Voltage ( Secondary ) 11.6 Volts AC
Low Voltage (VA) (Sec) 35—105 VA
Max. Sec Amps 8.8 Amps
Isolation Class Class III SELV
IP Rating IP20
Thermal 115°C Cut-off, resettable.
Dimmable Yes
VOID
Typical LV Downlighter. 20, 35 or 50W Dichroic
150mm