Eterna ALMFBKFUL, ALMFWHEYE, ALMFBKGRI, ALMFWHGRI, ALMFWHFUL Installation Instructions Manual

...
Page 1
INSTALLATION INSTRUCTIONS
A guide for qualied electricians
Email: sales@eterna-lighting.co.uk / technical@eterna-lighting.co.uk
Visit our website: www.eterna-lighting.co.uk
Made in ChinaIssue 0117
874/2012
MODELNO.
Aluminium Range
Regulations require the recycling of Waste from Electrical and Electronic Equipment (European “WEEE Direc tive” eective August 20 05—UK WEEE Regulation s eective 2nd January 20 07). Environment Agenc y Registered Producer : WEE/ GA0248Q Z.
WHEN YOUR PR ODUCT COMES TO TH E END OF ITS LIFE OR YO U CHOOSE TO REPLACE I T, PLEASE RECYCLE IT W HERE FACILITIES E XIST  DO NOT DISPOSE WITH HOUSEHOLD WASTE.
CLEANING:
Clean this ttin g only with a soft dry clo th.
Do not use any chemic al or abrasive cleaners.
IF YOU EXPERIENCE PROBLEMS:
If you believe your p roduct is defective, p lease return it to the place where yo u bought it. Our Technical Team will gladly advise on any Eterna Lighting product, bu t may not be able to give specic instructions regarding individual installations.
LED LAM P SPECIFICATIO NS:
FULL / GRILL EYELID
Luminaire lumens (opal)
1400 lm 1300 lm
Lumens from chip (no diuser)
1900 lm 1750 lm
Useful lumens
1350 lm 1250 lm
Rated Wattage 18W 18W
Rated luminous ux 1350 lm 1250 lm
Nominal life time of the lamp 35,000 hrs 35,000 hrs
Colour temperature 4200K 4200K
Number of switching cycles before premature lamp failure
>15,000 >15,000
Warm-up time up to 60% of the full light output
Instant full light Instant full light
Dimmable No No
Nominal beam angle 120° 120°
Rated power 18W 18W
Rated lamp lifetime 35,000 hrs 35,000 hrs
Lamp power factor >0.9 >0.9
Lumen maintenance factor at end of nominal life
>0.7 >0.7
Starting time <0.1s <0.1s
Colour rendering >80 Ra >80 Ra
Colour consistency
Within 6 step
Macadam ellipse
Within 6 step
Macadam ellipse
Rated peak intensity 520cd 520cd
Rated beam angle 120° 120°
Voltage / Frequency 240V~50Hz 240V~50Hz
Not suitable for accent lighting
Model:
ALMFBKFUL / ALMFWHFUL
ALMFBKEYE / ALMFWHEYE
ALMFBKGRI / ALMFWHGRI
IP65 LED Aluminium Wall Lights With Multi-Function Sensor
These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION
AND RETAIN FOR FUTURE REFERENCE
Pack contents:
1 x LED tting
Page 2
READ THIS FIRST:
Check the pack and m ake sure you have all of the parts liste d on the front of this bookle t. If not, contact the outlet where you bought this product.
This produc t must be installed by a compet ent person in accord ance with the current building a nd IEE wiring regulations.
As the buyer, install er and/or user of this product it is your own responsi bility to ensure that this tt ing is t for the purpo se for which you have intended it. Eterna Lightin g cannot accept any liability fo r loss, damage or premature failure resulting from inappropriate use.
This product is designed and constructed according to the principles o f the appropriate British Stan dard and is intended fo r normal domestic ser vice. Using this tting in any oth er environments may result in a shortened w orking life, for example w here there is prolonged p eriods of use or higher than no rmal ambient temper atures such as lighting public or shared spaces or in n ursing /care home facilities.
Switch o the mains be fore commencing installati on and remove the appro priate circuit fuse or lock o MCB.
Suitable for outdoor use.
This produc t is designed for permanent co nnection to xed wiring: this m ust be a suitable circuit (protected w ith the appropriate MCB or fuse).
This produc t is suitable for installatio n on surfaces with normal ammability e.g. wood, plasterboard and masonry. It is not s uitable for use on highly ammable sur faces (e.g. polystyren e, textiles).
Before makin g xing hole(s), check that there are no obstructi ons hidden beneath the mount ing surface such as pipes or cab les.
The chosen loc ation of your new tting shou ld allow for the prod uct to be securely mounte d (e.g. to a ceiling joist) and s afely connected to the mai ns supply (lighting circuit).
When making con nections ensure that the ter minals are tightened se curely and that no strands of wi re protrude. Chec k that the terminals are tightene d onto the bared cond uctors and not onto any insulation.
This produc t must be connected to ear th termination.
This produc t is not intended to be used by childr en and persons wi th sensory, physical and/or ment al impairments th at would prevent them from using i t saf ely.
You are advised at ever y stage of your installatio n to double-check any electrical connections you have made. After you h ave completed your installatio n there are elec trical tests that should b e carried out,
these tests are sp ecied in the current IEE wir ing and building regulations.
INTRODUCTION:
The LED Aluminium Wall L ight incorporates a microwave sensing de vice which continuously scans the operating zo ne and immediately switch es the light on when it det ects movement in that area. This means that whe never movement is detecte d within the range o f the sensor the light will switch on automaticall y and illuminate the area you have selected to l ight. While there is movement wi thin range of the unit th e light will remain on.
A microwave sensor is an a ctive motion detecto r emitting high -frequency ele ctro-magnetic waves at
5.8GHz and rece iving their echo. The senso r detects change in the echo p attern within its detec tion zone and the light is th en triggered. The wave can pass through doo rs, glass and thin walls and will continually monit or the signal within the detec tion area.
LAMP REPLACEMENT:
INSTALLATION:
Isolate mains and lo ck o.
Choose the loc ation for your new tting accor ding to the conditions listed opposite.
01. Undo the screws ret aining the trim and lift o.
02. Loosen gear tray s crews and rotate to remove.
03) Using the back o f your tting as a template, mark the positio n of your xing holes on your mounting surf ace.
04) Prepa re the holes in your mounting sur face as appropriate for your xings.
05) Pierce the r ubber grommet in the back of yo ur tting makin g a hole just large enough to make a tight t around the in coming mains cable.
06) Threa d the cable through the gromm et and oer the tting to the ce iling / wall.
07) Secure t he tting in place.
08) Check t hat the grommet is still correc tly tted in the cable entry hole and around the incoming cable.
09) Make the e lectrical connec tions according to the symbols, adj acent to the connector bloc k:
Brown to live (L) Blue to neutral (N) Earth green & y ellow (E)
10) Set the multi -function sensor. (See “understanding the controls” instructions on next page).
11) Conne ct the plug / socket betw een terminal block & gear tray.
12) Replace gear tray an d screw in position with the three screws.
NOTE: For eyelid  ttings - ensure the arrows on the gear tray and bas e match up.
13) Oer the diuse r onto the top of the tting and secure in place wi th the trim.
14) Restore the pow er and switch on.
The light source cont ained in this luminaire shall only be rep laced by the manufacturer, service age nt or a similar qualied pers on.
CAUTION, RISK OF ELECTRIC SHOCK.
The light source is designed to last the lifetime of the luminaire.
Yellow/Green
EARTH
L
N
Blue/Black
Brown/Red
NEUTRAL
LIVE
Page 3
MULTIFUNCTION SENSOR SPECIFICATIONS:
UNDERSTANDING THE CONTROLS:
Refer to the tabl e (g. 1) below.
The sensor is an ac tive motion detector : it emits a high frequenc y electromagneti c wave 5.8GHz and receives its ech o. The sensor detects th e change in echo from movem ent in its detection zone . A microprocesso r then triggers the switch li ght ON command. Detection is possible through doors, panels of glass and t hin walls.
DETECTION AREA:
This determine s the eective range of the m otion detector and i s set up by DIP switches at the sens or, refer to g. 2 opp osite. Note that reducing the sensitivity will also narrow the detection range.
The following settings are available:
I - Detection R ange 100% II - Detectio n Range 75% III - Detecti on Range 50% IV - Detectio n Range 10%
HOLD TI ME:
This determine s the time the tting remains at 100% level on motion d etection and is set with DI P switches at the se nsor, refer to g. 2 opposite. The walk test sett ing is useful when installi ng the tting to establish correct operation and range.
The following settings are available:
I - Walk test mode 5s II - 90s III - 3 minutes IV - 10 minutes
DAYLIGHT SE NSOR:
This setting h olds o the 100% light output sho uld there be sucien t daylight and is set using DIP switches at the se nsor, refer to g. 2 opposite.
The following settings are available:
I - Photocell disabl ed II - 50 lux twilight o peration III - 15 lux twilight ope ration IV - 5 lux darknes s operation only
* In dayli ght setting the lamp(s) will always b e on
with motion dete cted and operate at 100% light output, even in br ight daylight.
CORRIDOR FUNCTION:
This setting determines how long the tting should operate at 10% output a fter the hold time has elapsed and is se t by DIP switching at the sensor, refer to g. 2 opp osite.
NOTE: Setting at 0 s disables this function; s etting at +
leaves it permane ntly at 10% output until
activated again.
The following settings are available:
I - 0s II - 30s III - 10 minutes IV - +
Detection Area Hold Time Daylight Sensor Corridor Function
1 2 3 4 5 6 7 8
I ON ON 100% I ON ON 5s I ON ON
Disable
I ON ON 0s
II - ON 75% II - ON 90s II - ON 50Lux II - ON 30s
III ON - 50% III ON - 3min III ON - 15Lux III ON - 10min
IV - - 10% IV - - 10min IV - - 5Lux IV - -
+
ON
OFF
Model number MLC16C- P
Operating voltage 220-240Vac, 50/60Hz
Output constant current
300mA / 350mA, s et via DIP
switch
Output voltage 28- 48Vdc
Eciency ≥80%
Power fac tor ≥0.9
HF system
5.8GHz ± 75MHz, ISM wave band
Transmitting power <0. 5mW
Detection z one max. 16m (D) x 6m (H)
Dectection sensitivit y 10% / 50% / 75% / 100%
Hold time 5s / 90s / 3 min / 10 min
Corridor function 0s / 30s / 10 min / Disable
Daylight sensor 5lux / 15lux / 50lux / Disable
Standby dimming level 10% - can be customised
Mounting height 6m Max. Motion detection 0.5~3m/s
Detection angle
150° (wall installation)
360° (ceiling insta llation)
Fig 1
Detection Area
Daylight Sensor
Hold Time
Daylight Sensor
Corridor function
Fig 2
RED DIRECTIVE Eterna Lighting Ltd
Microwave Occupancy Sensor
Full declaration available at www.eterna-lighting.co.uk
Loading...