Thank you for purchasing the Dual Mode Thermometer by Etekcity. This device offers rapid reading and simple operation for measuring both eardrum and forehead temperature. This multifunctionality offers a safer and simpler solution in temperature analysis for subjects ranging from the age of infancy to seniors. It eliminates the potential dangers of glass thermometers and
EN
mercury with highly accurate infrared scanning measurement. Know body temperatures in an instant and recall from a history of up to 20 past measurement results. The Dual Mode Thermometer also includes a fever alert when results are high, so you can act fast for a quicker recovery. A simpler life starts here.
IMPORTANT:
Please read, understand, and comply with all the instructions provided in this manual before using the device. Failure to comply with the instructions given in this manual and/or using the device in ways other than the ones mentioned in this manual may result in serious injury and/or damage to the product.
NOTE:
The thermometer has a precision of ±
(±0.4°F)
. Should you ever receive a high fever alert from the thermometer, it is recommended to consult your primary physician before taking any further action.
2
0.2°C
Contents
Safety Use & Care ......................................................... 4
Features ......................................................................... 6
Current Consumption .................................................. 7
Function Diagram ......................................................... 7
Icon Key ..........................................................................8
Set-Up ..............................................................................8
Operation........................................................................9
Cleaning and Maintenance ........................................11
Error Indications ...........................................................11
Troubleshooting ...........................................................12
Security Type ................................................................14
Authorized European Representative ....................14
Package Contents ........................................................15
3
ENEN

Safety Use & Care

y The thermometer is intended for indoor use. Wind
turbulence will adversely affect the accuracy of the
device. yKeep the thermometer out of children’s reach. yDO NOT use this device on newborn infants.
EN
yThis device is not intended for continuous monitoring. y It is recommended to clean the thermometer sensor
after each use with a cotton swab and rubbing alcohol. y To avoid result inaccuracy, DO NOT clean directly
before use.
yDO NOT touch or blow on the sensor’s probe tip. y Avoid measuring temperature for at least 30
minutes after exercise, bathing, or returning from
the outdoors. y DO NOT submerge the thermometer in any type of
liquid, it is not waterproof. y If the device shows any sign of damage, do not use
it. Contact customer service at support@etekcity.
com for assistance . y DO NOT tamper with the thermometer’s internal
components. Doing so will invalidate the warranty
on this device and may cause damage. y DO NOT subject the device to excessive force,
4
shock, dust, temperature or humidity. This may result in malfunction, shorter electronic life span, damaged battery and/or distorted parts.
y This device is not intended to substitute any
advice given by a physician, pharmacist, or other licensed health-care professional. You should not use this product for self-diagnosis or for treating a health problem. Contact your health-care provider immediately if you suspect that you have a medical problem.
y DO NOT use the product in a wet ear canal or on
foreheads with heavy perspiration. Doing so may cause inaccuracy in the temperature results.
y It is not recommended to use the product on
subjects suffering from any ear disease or infection including otitis externa or tympanitis, as this may aggravate such conditions.
y If the device fails to turn on, check whether the
batteries are installed correctly. Replace the batteries if necessary.
y If the thermometer is not in use for an extended
period of time, remove the batteries to conserve battery lifetime.
y If there is a large difference between two
consecutive temperature results, wait 10 minutes before retaking temperature measurements with the thermometer.
5
ENEN
y The thermometer contains sensitive electronic
components that should not be used under
conditions with electromagnetic interference.

Features

yABS Plastic
EN
yInfrared temperature measurement yMeasure forehead and ear temperature yBacklit display yFever warning buzzer (37.5°C / 99.5°F or higher) yMemory recall of 20 previous readings yTemperature Units: °C / °F yForehead Temperature Range: 32°C ~ 42.2°C
(89.6°F~ 107.9°F) yEardrum Temperature Range: 0°C ~ 100.0°C
(32.0°F~ 212.0°F) yPrecision: ± 0.2°C / ± 0.4°F yWorking Temperature: 10°C ~ 40°C (50°F~ 104°F) yWorking Humidity: <80% RH, non- condensing yAtmospheric Pressure: 860hPa ~ 1060hPa yDisplay Resolution: 0.1°C / 0.1°F yLatency Time: 1 second ySound: ≥ 50db
6
yAuto -Off: 10 ± 1 second yBattery: 2 x AAA 1.5V batteries

Current Consumption

Standby <2μA Working <0.5mA
Buzzer <2mA
Backlight <15mA

Function Diagram

1
2 3 45 6
1. Eardrum sensor cover
2. Sensor
3. F1: Forehead temperature analysis
4. F2: Eardrum temperature analysis
5. LCD display
6. Battery compartment
7
ENEN

Icon Key

Icon Message
The measured value is over the maximum
H°C
temperature range. The measured value is below the minimum
L°C
EN
temperature range. Eardrum temperature measurement mode.
Forehead temperature measurement mode. Temperature is above of the normal human
body temperature. (89.6°F ~ 107.9°F / 32°C ~
42.2°C). Memory recall mode.
M

Set-Up

The 2 AAA 1.5V batteries are preinstalled in the device battery compartment. Open the battery compartment cover located on the thermometer handle and remove the protective plastic film. Re- apply the batteries under the correct polarity and reseal the battery compartment in order to activate the thermometer.
8

Operation

Forehead Temperature Analysis
1. Before measuring forehead temperature, make sure
there is no water, sweat, or direct sunlight on the forehead.
2. Press and hold ‘F1’ while slowly scanning the entire
forehead from one temple to the other. Make sure to keep the thermometer in contact with the forehead at all times while moving from one side of the forehead to another.
3. Release the ‘F1’ button. The temperature results will
appear on the LCD display. A second measurement may be taken once the LCD backlight turns off.
NOTE:
K eeping the infrared scanner at one point may affect the accuracy of temperature results. Make sure to move the thermometer across and in contact with the forehead for better temperature result accuracy.
Eardrum Temperature Analysis
1. Remove the sensor plastic cover.
2. Before measuring eardrum temperature, clean out
the ear canal.
3. Gently insert the sensor tip fully into the ear canal.
4. Press ‘F2’ while holding the sensor in the ear canal.
The thermometer will chime and the temperature results will appear on the LCD display.
9
ENEN
Note:
Make sure to dry the ear canal and keep the sensor contact with ear canal for better temperature result accuracy.
Fever Alert:
W hen measuring temperature in either of the two modes, the thermometer will sound 7 short ticks and the LCD display will flicker if the reading
EN
results exceed 37.5°C / 99.5°F to indicate that the subject may have a fever.
Auto -Off:
I f left idle for 10 seconds, the thermometer
will shut off automatically to conserve battery lifetime.
Memory Recall
1. When the thermometer is on standby, press and hold
the ‘F2’ button for 4 to 8 seconds. The LCD screen will display ‘ - - - M’ w ith the ‘M’ letter blinking.
2. Press ‘F2’ once more and the LCD screen will display
data with a corresponding icon indicating what mode the results are under.
Unit Conversion
While the device is off, press and hold ‘F2’ for 8 to 12 seconds. The current unit of measurement will appear. Press ‘F2’ once more to change and select the desired unit. NOTE: W hile holding the ‘F2’ button, the memory interface will first appeal. Keep holding the button until the unit changing interface appears.
10

Cleaning and Maintenance

Inaccurate results may occur if the thermometer is not regularly cleaned. The thermometer sensor is extremely sensitive to dirt and oil, so make sure to check that it is clean before each use. If cleaning is necessary, gently clean with medical alcohol and a cotton swab or Q-tip until the sensor is no longer dull or lackluster.

Error Indications

Error
Message
“Er 1”
“ErC”
Reason Indication
Ambient temperature exceeds 40°C / 104°F
or is below 10°C / 50°F
minimum readable
temperature
EEPROM data reading
error (contact customer
service) or Incomplete
analysis
Battery power is low, replace the batteries
11
3 short ticks and
green backlight activation for 3
seconds
3 short ticks and
green backlight activation for 3
seconds
ENEN

Troubleshooting

Symptom Possible Cause Solution
Physical condition is
EN
unstable.
Unreadable status.
The difference in consecutive
measurements
is too high. (Forehead)
Measurement operation error.
Sensor too far. Make sure the probe
12
Allow the subject to rest for about 30 minute before trying again.
Make sure the forehead is completely clean and dry without any perspiration. Also, make sure that the subject is not in direct sunlight during measurement.
Make sure to slowly scan across the forehead while keeping in contact. Do not keep the sensor in place when measuring forehead temperature.
is in contact with the forehead when scanning.
Symptom
The difference
in consecutive
measurements
is too high. (Forehead)
Possible Cause Solution
If your warranty has
Faulty device.
not expired, contact Etekcity’s customer support.
Physical condition is unstable.
Allow the subject to rest for about 30 minute before trying again.
ENEN
The difference
in consecutive
measurements
is too high. (Ear Canal)
Unreadable status.
Incorrect sensor placement.
Faulty device. If your warranty has
Make sure the ear canal and eardrum is completely clean and dry before measurement.
Make sure the sensor is fully inside the ear canal without harming the subject.
not expired, contact Etekcitys customer support.
13
NOTE:
Normal human body temperatures vary depending on the body location. When taking temperature from different parts of your body, it is normal to obtain a slight variation in the temperature readings. An ear (tympanic) temperature is usually 0.5-1°F (0.3-0.6°C) higher than an oral temperature, whereas a forehead (temporal) temperature is usually 0.5-1°F (0.3-0.6°C)
EN
lower than an oral temperature. Therefore, it is
NORMAL
an ear measurement versus a forehead measurement. This is NOT due to the inaccuracy of the thermometer.

Security Type

This signal indicates that thermometer is a BF
type device with internal power supply.

Authorized European Representative

EC REP
1-2°F (0.6-1.2°C)
to get
Wellkang Ltd Suite B, 29 Harley Street, London, W1G9QR, U.K.
14
difference between

Package Contents

1 x Dual Mode Thermometer 1 x Storage Bag 2 x AAA 1.5V batteries (installed) 1 x User Manual
15
ENEN
EN
Please contact us
at
(855) 686-3835
www.etekcity.com
Visit
Mon-Fri 9:00 AM - 6:00 PM PST
support@etekcity.com
or email
for more products.
16
Duales Fieberthermometer
Modell Nr.: JPD-FR100+
Fragen oder Anliegen? support.eu@etekcity.com
Besuchen Sie auch etekcity.com für weitere Produkte
1
ENDEDE
Vielen Dank für den Erwerb dieses dualen Fieberthermometers von Etekcity. Dieses Thermometer erlaubt Ihnen das schnelle Ablesen und den einfachen Betrieb sowohl zur Messung der Trommelfellals auch der Stirntemperatur. Diese Multifunktionalität stellt eine sicherere und einfachere Lösung zur Temperaturmessung bei allen Patienten vom Kleinkind­bis zum Seniorenalter. Es eliminiert die Gefahren von Glasthermometern und Quecksilber und bietet eine hochpräzise Infrarotscan-Temperaturmessung. Es kann sowohl die aktuelle Körpertemperatur bestimmen als auch die letzten 20 Messergebnisse anzeigen. Das duale Fieberthermometer besitzt außerdem einen Fieberalarm, der bei hohen Messwerten warnt, damit Sie schnell handeln und so die Erholungsphase verkürzen können. Ein einfacheres Leben beginnt hier.
WICHTIG: Bitte lesen, verstehen und beachten Sie alle Anweisungen, die in diesem Handbuch beschrieben sind, bevor Sie das Gerät benutzen. Das Nichtbeachten der Instruktionen dieses Handbuchs und/oder der Einsatz des Gerätes für andere, hier nicht beschriebene, Zwecke, können zu ernsthaften Verletzungen und/oder zu Schäden am Produkt führen!
2
INHALTSVERZEICHNIS
SICHERHEITSHINWEISE UND HANDHABUNG .......4
FUNKTIONEN UND TECHNISCHE
SPEZIFIKATIONEN .......................................................6
STROMVERBRAUCH .................................................... 7
FUNKTIONSSCHEMA ...................................................8
ERKLÄRUNG DER SYMBOLE .....................................8
INBETRIEBNAHME .......................................................9
BENUTZUNG ..................................................................9
REINIGUNG UND PFLEGE ..........................................12
FEHLERMELDUNGEN .................................................12
FEHLERBEHEBUNG .....................................................13
SICHERHEITSTYP ........................................................15
Authorized European Representative ....................15
LIEFERUMFANG ...........................................................15
3
ENDEDE

SICHERHEITSHINWEISE UND HANDHABUNG

y Das Thermometer ist nur zum Einsatz in
geschlossenen Räumen zugelassen. Luftturbulenzen können die Genauigkeit der Messung beeinflussen.
yBewahren Sie das Thermometer außerhalb der
Reichweite von Kindern auf.
yBENUTZEN Sie dieses Thermometer NICHT bei
Neugeborenen.
yDieses Gerät ist nicht für die kontinuierliche
Überwachung geeignet.
yEs wird empfohlen, den Temperatursensor nach
jeder Benutzung mit einem Wattestäbchen und Reinigungsalkohol zu reinigen.
yBERÜHREN oder blasen Sie die Fühlerspitze des
Messgerätes NICHT an.
yVermeiden Sie es, die Temperatur weniger als 30
Minuten nach einer sportlichen Betätigung, nach dem Baden oder nach der Rückkehr von Draußen zu messen.
yTAUCHEN Sie das Thermometer in KEINE Flüssigkeit,
es ist nicht wasserdicht.
yWenn das Gerät auf irgendeine Art beschädigt ist,
dann verwenden Sie es nicht. Nehmen Sie Kontakt zu unserem Kundendienst aus, um Hilfe zu erhalten.
yNEHMEN Sie KEINE Änderungen an den internen
4
Komponenten des Thermometers vor. Das Nichtbeachten führt zum sofortigen Garantieverlust und kann Schäden verursachen.
ySETZEN Sie das Gerät KEINEN starken Kräften,
Erschütterungen, Staub oder Feuchtigkeit aus. Dies kann zu Fehlfunktionen, zu
einer kürzeren Lebenszeit der Elektronik, zu Schäden an den Batterien und/oder zur Deformierung der Komponenten führen.
yDieses Gerät ist kein Ersatz für eine Meinung
eines Arztes, Apothekers oder anderen Gesundheitsexperten. Sie sollten dieses Gerät nicht zur Selbstdiagnose oder zur Behandlung eines gesundheitlichen Problems verwenden. Nehmen Sie sofort Kontakt zu Ihrem Arzt auf, wenn Sie glauben, an einem medizinischen Problem zu leiden.
yBENUTZEN Sie das Gerät NICHT in einem feuchten
Gehörgang, wie er beim Baden oder durch das Schwimmen entsteht, weil das zu Schäden am Gehörgang führen kann.
yDas Gerät darf nicht bei Personen verwendet
werden, die an einer Erkrankung oder Infektion der Ohren, wie z. B. einer Außenohrentzündung (Otitis externa) oder einer Entzündung des Gehörgangs (Tympanitis), leiden, weil dies die Krankheit verschlimmern kann.
yWenn sich das Gerät nicht einschalten lässt, dann
5
ENDEDE
prüfen Sie bitte, ob die Batterien korrekt eingelegt sind. Ersetzen Sie, wenn nötig, die Batterien.
yWenn das Thermometer für längere Zeit nicht
verwendet wird, dann entfernen Sie die Batterien, um deren Lebensdauer zu verlängern.
yWenn es große Unterschiede zwischen zwei
aufeinanderfolgen den Temperaturmessungen gibt, dann warten Sie bitte 10 Minuten ab, bevor Sie eine weitere Messung vornehmen.
yDas Thermometer enthält empfindliche, elektronische
Bestandteile, die nicht unter Bedingungen mit elektromag netischen Interferenzen verwendet werden sollten.
FUNKTIONEN UND TECHNISCHE
SPEZIFIKATIONEN
yABS-Plastik yInfrarottemperaturmessung yMessung der Stirn- und der Ohrtemperatur yHintergrundbeleuchtetes Display yFieberwarnsignal (37,5 °C/99,5 °F oder höher) ySpeicherfunktion für die letzten 20 Messungen yTemperatureinheiten: °C/°F yTemperaturmessbereich für die Stirntemperatur:
32,0°C ~ 42,2 °C (89,6°F ~ 107,9 °F)
6
yTemperaturmessbereich für die
Trommelfelltemperatur: 0,0°C ~100,0 °C (32,0°F ~ 212,0 °F)
yPräzision: ±0,2 °C/±0,4 °F yArbeitstemperatur: 10°C~ 40°C (50°F ~ 104 °F) yLuftfeuchtigkeit während des Betriebs: <80% rel.
Luftfeuchte, nicht-kondensierend
yArbeitsbereich für den atmosphärischer Druck:
860hPa ~1060 hPa
yGenauigkeit der Anzeige: 0,1 °C/0,1 °F yLatenzzeit: 1 s yLautstärke des Alarms: ≥50 dB yAuto-Abschaltung: 10±1 s yBatterien: 2x AAA 1,5 V-Batterien

STROMVERBRAUCH

Stand-By <2μA
Im Betrieb <0.5mA
Alarmsignal <2mA
Hintergrundbeleuchtung <15mA
7
ENDEDE

FUNKTIONSSCHEMA

1
2 3 45 6
1. Trommelfellsensorabdeckung
2. Sensor
3. F1: Messung der Stirntemperatur
4. F2: Messung der Trommelfelltemperatur
5. LCD-Display
6. Batteriefach

ERKLÄRUNG DER SYMBOLE

Symbol Erklärung
Die gemessene Temperatur liegt über der
H°C
Maximaltemperatur. Die gemessene Temperatur liegt unter der
L°C
Minimaltemperatur. Messung der Trommelfelltemperatur Messung der Stirntemperatur
8
Loading...
+ 54 hidden pages