ETC Source Four Mini LED 50 Degree Installation Guide

ETC Installation Guide
Canopy mount
Track mount
Source Four Mini™ LED Canopy and Track Mount Kits

Introduction

This guide illustrates the installation of the Canopy and Track Mount kits for the Source Four Mini LED fixture. For additional information, see the Source Four Mini LED User Manual that shipped with your fixture.
WARNING:
TURN OFF POWER at main fuse or breaker box and verify that the power is off before proceeding with installation.
Wiring must meet local and national codes. Do not mount the fixture on or near combustible surfaces. Do not operate the fixture without a lens installed. Always hang the fixture with the color frame retaining clip in the
locked position.
Corporate Headquarters London, UK
 Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK  Tel +44 (0)20 8896 1000  Fax +44 (0)20 8896 2000
Rome, IT 
Via Pieve Torina, 48, 00156 Rome, Italy  Tel +39 (06) 32 111 683  Fax +44 (0)20 8752 8486
Holzkirchen, DE Hong Kong  Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong  Tel +852 2799 1220 Service:
(Americas) service@etcconnect.com
Web:
www.etcconnect.com
7063M2110 
 3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA  Tel +608 831 4116  Fax +608 836 1736
 Ohmstrasse 3, 83607 Holzkirchen, Germany  Tel +49 (80 24) 47 00-0  Fax +49 (80 24) 47 00-3 00
Rev A  Released 2014-02  ETC intends this document to be provided in its entirety.
Copyright © 2014 ETC. All Rights Reserved.  Product information and specifications subject to change.
(UK) service@etceurope.com  (DE) techserv-hoki@etcconnect.com
(Asia) service@etcasia.com
ETC Installation Guide
Back box (not provided)
Mounting plate
Canopy screws
Ground braid
Mounting plate screws
Canopy plate: the four indentations allow for multiple screw nesting positions.
Ground screw
Source Four Mini LED

Canopy Installation Procedure

Step 1: Remove the mounting plate from the fixture by removing the two
Step 2: Using the mounting plate screws, secure the mounting plate to the
CAUTION:
canopy screws and the ground screw. Set the ground screw safely aside.
installed electrical box, which is not included.
The metal canopy plate has built in indentations allowing the mounting plate screws to nest into the canopy plate. For an ideal flush mount installation you may need to rotate the plate to accommodate these indentations. See the following graphic for additional information.
Canopy and Track Mount Kits Page 2 of 4
ETC Installation Guide
Canopy screw hole
3
2
1
3
2
1
Mounting plate screw
installation detail
Canopy screw hole
Install the mounting plate screws in one of the three position­pairings shown.
Only the slots on the outer circumference will allow a true flush mounting.
Source Four Mini LED
Step 3: Place the copper ground braid loop over the ground screw and attach
the ground screw to the back box.
Step 4: Connect the building ground wire to the ground wire on the fixture,
following local electrical codes.
Step 5: Connect your supply power wires to the lamp wiring using the included
two-position Wagos.
For 120V fixtures: Connect the black wire to line and the white wire to neutral. For 230V fixtures: Connect the brown wire to line and the blue wire to neutral.
Step 6: While keeping in mind the mounting plate orientation, use the canopy
screws to secure the fixture to the mounting plate.
Step 7: Open all four of the shutter blades by sliding them outward until they
Step 8: Install a gobo and gel as desired and confirm that they are properly
Step 9: Restore power at the main fuse.
Step 10: Focus the fixture as desired.
stop.
secured.
Page 3 of 4 Canopy and Track Mount Kits
ETC Installation Guide
Circuit selection
wheel
Lock
Tabs
There are cable protection posts
on both the yoke lock and the
yoke that prevent the fixture from
rotating a full 360°.
The yoke can be locked into
place using a 1.5mm Allen
wrench.
Source Four Mini LED

Track Installation Procedure

WARNING:
AVERTIR:
Step 1: Insert the track adapter into the
Step 2: Lock the adapter into place.
Step 3: Select circuit 1 or 2 using the
The 230V track adapter has a three­circuit selector knob.
Step 4: Focus the fixture.
Step 5: Lock the fixture into place using the yoke lock.
To reduce the risk of fire and electric shock, use only with EUTRAC track system.
Réduire le risque de feu et la décharge électrique, l'usage seulement avec le systéme de piste d'EUTRAC.
track. The adapter will only fit one way into the track with the tabs of the adapter in the groove of the track.
circuit selection wheel.