DECLARATION OF CONFORMITY
We, Electronic Theatre Controls, Europe Limited
Unit 5, Victoria Industrial Estate, London W3 6UU United Kingdom declare under sole responsibility that
the product:
Product name: Source Four MultiPAR
Product type/model: MultiPAR 1x12 & MultiPAR 1x3
Lot: n/a
Batch / Serial number: n/a
Item numbers: one of each type
To which this declaration relates is in conformity with the following Standards:
EN60598-1:2000 Luminaires, General requirements and tests
EN60598-17:1990 Luminaires, Particular requirements, Specification for luminares for
stage lighting, television, film and photographic studios (outside and
indoor) - equiv. BS 4533-102.17:1990
Following the provisions of EU LV Directive(s) 73/23/EEC
EMC: None Unit is EMC benign
London, United Kingdom
Adam Bennette
(Place of issue) (Name of authorised person)
25th Feb 2003
(date of issue) (signature of authorized person)
Electronic Theatre Controls Europe Ltd. Registered office:
Unit 5, Victoria Industrial Estate, Grant Thornton House
Victoria Road, London W3 6UU U.K. Melton St., London, NW1 2BW, England
Telephone (+44) 181 896 1000 Registered in England No.3057796
Fax (+44) 181 896 2000 VAT No. 662 9487 90
English
Source Four MultiPAR CE guidelines
The Source Four MultiPAR CE is intended for professional use only. Read the entire User Guide before using
equipment.
Please note the following safety precautions:
• Do not mount the Source Four MultiPAR CE on or near a flammable surface.
• Use the Source Four MultiPAR CE in dry locations only, where humidity does not exceed 90 percent.
• The fixture is for indoor use only and is not intended for outdoor use.
• For temporary installations, mount and support the Source Four MultiPAR CE only by the primary suspension
yoke holes. Suspend the fixture from a hook clamp or a stand mount, using a securely tightened steel bolt (up to Ø
12 mm), flat washer and locking washer.
• In addition to primary suspension, attach a safety cable (Model 400SC) or chain to the secondary suspension
point on the Source Four MultiPAR CE.
• If the external cable is damaged, it shall be replaced by ETC or our service agents.
• Always hang the Source Four MultiPAR CE with the colour frame held securely behind the MultiPAR retaining
channel.
• Always replace the lamp if it becomes damaged or thermally deformed.
• Lighted objects at this distance or greater will not exceed 90ºC temperature from projected light.
• Disconnect the unit from power before all cleaning and maintenance.
• The Source Four MultiPAR CE is suitable for indoor use with a maximum ambient temperature: Ta=45°C
• Maximum exterior surface temperature: T
• A multilingual label sheet is included with this manual. Affix the label of the appropriate language over the existing
warning label on the extension yoke. Do not cover ETC trademark or CE mark.
• The Source Four MultiPAR CE contains a CE safety screen that covers the lens in the event of accidental discharge. Do not remove the safety screen.
• Keep the luminaire at least 0.7 meters away from anything it is shining on.
max
=200ºC
0.7m
Wiring and power information
A plug of at least 2.5 amp (220/240V) rating should be attached to the fixture’s mains lead. The wires in the mains
lead are 1.5mm2 each and coloured in accordance with the following code:
Green and Yellow:
Blue: Neutral
Brown: Live
Earth
t 180°c
WARNING: The CE Source Four MultiPAR must be earthed.
Current rating: 240V/2.5 amp maximum
Operating frequency:
50/60Hz
Power requirements
The Source 4 MultiPAR CE has several different standard, as well as custom configurations of electrical circuitry.
Make certain you are familiar with the wiring of the MultiPAR and that you have sufficient power (dimmer capacity)
to operate the fixture. Make sure that the total wattage used by your MultiPAR does not exceed the power avail
able by dimmer.
4 Source Four MultiPAR CE
-