The Source 4WRD PAR and PARNel Fixture Bodies allow you to transform your Source
4WRD LED into a beautiful softlight. Taking advantage of the great energy efficiency,
cool operating temperatures, DMX dimming or line voltage dimming and no lamp
changes, the Source 4WRD PAR and PARNel deliver an amazing output without
compromise.
APPLICATIONS
• House of worship
• Universities and schools
• Hospitality
• Retail
• Exhibition centers
• Meeting rooms
• Clubs
• Cafetoriums
PRODUCT FEATURES
• Fixture bodies for use with Source 4WRD LED
• Works just like a Source Four PAR or PARNel, using the same accessories
• 155W at full output
• Brighter than the 750W HPL versions
• Uses same Source 4WRD LED as the Source 4WRD ellipsoidal
ORDERING INFORMATION
S4WRD PAR and PARNel Fixture
Bodies
MODELDESCRIPTION
S4WRDPARS4WRD PAR Fixture Body,
Black
S4WRD PARNelS4WRD PARNel Fixture
Body, Black
Color Options: Fixture body ships standard in black. For
additional colors please use the below color code suffix:
Add -1 for white or -5 for silver
Notes: Source 4WRD LED and c-clamp sold separately.
SOURCE 4WRD PAR AND PARNel FIXTURES
SHIP WITH:
• Color frame
• PAR ships with AR coated flat lens
(other lenses sold separately)
• PARNel ships with PARNel lenses
1 of 14
ETC
®
PRODUCT SPECIFICATIONS
Source 4WRD PAR/PARNel Fixture Body
Source 4WRD Series
Source
LED DetailsS4WRD LED (48 Cree LEDs) *Not Included*
NotesPAR ships with an AR coated flat lens. Additional
No
PAR lenses sold separately. PARNel ships with
PARNel lenses.
Electrical
Voltage range114-125V, 60Hz
Input methodHard wired, 1-meter cord, Edison plug
Inrush30A (first half-cycle) at 120V
Fixtures per circuit14 (20A switched circuit, R20 module or similar)
Wattage (Typical/Standby)155W/1.2W
Current draw1.35A at 120V
NotesWhen using line dimming, see the S4WRD Manual
for dimmer setup
When using line dimming, standby power is 0W
Thermal
Ambient operating temp5-40° C (41-104° F)
Fan (controllable)Yes (no)
Droop compensationNo
dB range28dBa average at 1m
BTUs/hour529
Physical
MaterialsDie-cast aluminum
Color optionsBlack, white, silver or custom color
Mounting optionsYoke
IP ratingIP-20
WeightPAR: 6.6lbs / PARNel: 7.7lbs
Included accessoriesColor frame
NotesIncludes S4WRD mounting post. Required S4WRD
LED available separately
Control
Input methodLine Voltage with DMX Control or Line dimmed
ProtocolsDMX via RJ45 connector
Modes (Footprint)1
RDM configurationYes
UI type7-segment address display
Local controlYes
Onboard presetsNo
Onboard sequencesNo
Onboard effectsNo
Slave/Master controlNo
NotesLocal level control via UI
2 of 14
ETC
SPD (normalized to Y=100)
SPD (normalized to Y=100)
(nm)
®
PRODUCT FEATURES
Source 4WRD PAR/PARNel Fixture Body
Source 4WRD Series
BRIGHT!
Brighter than a 750W fixture while using
1/5th the power
USES YOUR EXISTING ACCESSORIES
Works just like a Source Four PAR and
PARNel
COLOR METRIC INFORMATION
TM-30-15 - 80CRI PAR
81
R
f
D
uv
0.0001
97
R
CCT
2894
INTERCHANGABLE WITH S4 PROFILES
You can interchange your Source 4WRD
LED sources between your S4 profile fixtures
and your Source 4WRD PAR and PARNel
fixture bodies
2.5
g
2
1.5
1
0.5
0
380430480530580630680730780
Test sourceReference source
λ (nm)
TM-30-15 - 80CRI PARNel
81
R
f
D
uv
0.0004
97
R
g
CCT
2889
3 of 14
2.5
2
1.5
1
0.5
0
380430480530580630680730780
Test sourceReference source
λ
ETC
SPD (normalized to Y=100)
(nm)
SPD (normalized to Y=100)
(nm)
®
COLOR METRIC INFORMATION
TM-30-15 - 90CRI PARNel
Source 4WRD PAR/PARNel Fixture Body
Source 4WRD Series
91
R
f
D
uv
0.0001
TM-30-15 - 90CRI PARNel
91
R
f
99
R
g
CCT
3008
99
R
g
2.5
2
1.5
1
0.5
0
380430480530580630680730780
2.5
2
1.5
Test sourceReference source
λ
Test sourceReference source
D
uv
0.0001
CCT
2996
Additional Color Metrics
PAR GALLERY PAR STANDARD PARNel GALLERYPARNel STANDARD
CRI Ra (R9)92 (59)81 (9)91 (57)81 (6)
TLCI92669165
1
0.5
0
380430480530580630680730780
λ
4 of 14
ETC
Field Angle
Beam Angle
Field Angle
Beam Angle
®
PHOTOMETRICS
Source 4WRD PAR/PARNel Fixture Body
Source 4WRD Series
Source 4WRD PAR 80CRI with AR Coated Flat Lens
ModeDegree CandelaField
Lumens
AR Coated
Flat
Metric conversions: For meters, multiply feet by 0.3048
19.5294,0009,0003,95415558.1
For lux, multiply footcandles by 10.76
9.319.5
Throw Distance (d)10ft
3.0m
Field Diameter3.4ft
1.0m
Illuminance (fc)2,9401,3077354701
Illuminance (lux)31,64614,0657,9115,06310.76
To determine center beam illumination in footcandles at any throw distance, divide
candela by the throw distance squared
For field diameter at any distance, multiply distance by 0.344
For beam diameter at any distance, multiply by 0.163
15ft
4.6m
5.2ft
1.6m
Beam
Lumens
20ft
6.1m
6.9ft
2.1m
Power
Consumption
25ft
542.2ft
7.6m
8.6ft
2.6m
165.3m
–
Lumens
Per Watt
Candela Plot
300000
250000
200000
150000
Candela
100000
50000
0
-15-10-5051015
Degrees
Iso-Illuminance Diagram
(Flat Surface Distribution)
X
Y
10%
50%
% illuminance
foot candle
or lux
Source 4WRD PAR 80CRI with VNSP Lens
ModeDegree CandelaField
Lumens
VNSP20.4234,0008,2904,02015553.5
Metric conversions: For meters, multiply feet by 0.3048
For lux, multiply footcandles by 10.76
10.420.4
Throw Distance (d)10ft
3.0m
Field Diameter3.6ft
1.1m
Illuminance (fc)2,3401,0405853741
Illuminance (lux)25,18811,1946,2974,03010.76
To determine center beam illumination in footcandles at any throw distance, divide
candela by the throw distance squared
For field diameter at any distance, multiply distance by 0.360
For beam diameter at any distance, multiply by 0.182
15ft
4.6m
5.4ft
1.6m
Beam
Lumens
20ft
6.1m
7.2ft
2.2m
Power
Consumption
25ft
483.7ft
7.6m
9.0ft
2.7m
147.4m
Lumens
Per Watt
–
Candela Plot
250000
200000
150000
Candela
100000
50000
0
-15-10-5051015
Degrees
Iso-Illuminance Diagram
(Flat Surface Distribution)
X
Y
10%
50%
% illuminance
foot candle
or lux
5 of 14
ETC
Field Angle
Beam Angle
Field Angle
Beam Angle
®
PHOTOMETRICS
Source 4WRD PAR/PARNel Fixture Body
Source 4WRD Series
Source 4WRD PAR 80CRI with NSP Lens
ModeDegree CandelaField
Lumens
NSP20.9222,0008,2303,94015553.1
Metric conversions: For meters, multiply feet by 0.3048
For lux, multiply footcandles by 10.76
10.620.9
Throw Distance (d)10ft
3.0m
Field Diameter3.7ft
1.1m
Illuminance (fc)2,2209875553551
Illuminance (lux)23,89610,6205,9743,82310.76
To determine center beam illumination in footcandles at any throw distance, divide
candela by the throw distance squared
For field diameter at any distance, multiply distance by 0.369
For beam diameter at any distance, multiply by 0.186
15ft
4.6m
5.5ft
1.7m
Beam
Lumens
20ft
6.1m
7.4ft
2.2m
Power
Consumption
25ft
471.2ft
7.6m
9.2ft
2.8m
143.6m
Lumens
Per Watt
–
Candela Plot
250000
200000
150000
Candela
100000
50000
0
-15-10-5051015
Degrees
Iso-Illuminance Diagram
(Flat Surface Distribution)
X
Y
10%
50%
% illuminance
foot candle
or lux
Source 4WRD PAR 80CRI with MFL Lens
ModeDegree CandelaField
Lumens
MFL34.795,4008,6404,74015555.7
Metric conversions: For meters, multiply feet by 0.3048
For lux, multiply footcandles by 10.76
20.934.7
Throw Distance (d)10ft
3.0m
Field Diameter6.2ft
1.9m
Illuminance (fc)9544242391531
Illuminance (lux)10,2694,5642,5671,64310.76
To determine center beam illumination in footcandles at any throw distance, divide
candela by the throw distance squared
For field diameter at any distance, multiply distance by 0.625
For beam diameter at any distance, multiply by 0.369
15ft
4.6m
9.4ft
2.9m
Beam
Lumens
20ft
6.1m
12.5ft
3.8m
Power
Consumption
25ft
308.9ft
7.6m
15.6ft
4.8m
Lumens
Per Watt
94.1m
–
Candela Plot
100000
80000
60000
Candela
40000
20000
0
-30-20-100102030
Degrees
Iso-Illuminance Diagram
(Flat Surface Distribution)
X
Y
10%
50%
% illuminance
foot candle
or lux
6 of 14
ETC
Field Angle
Beam Angle
Field Angle
Beam Angle
®
PHOTOMETRICS
Source 4WRD PAR/PARNel Fixture Body
Source 4WRD Series
Source 4WRD PAR 80CRI with WFL Lens
ModeDegree CandelaField
Lumens
WFL54.137,8207,7704,11015550.1
Metric conversions: For meters, multiply feet by 0.3048
For lux, multiply footcandles by 10.76
31.454.1
Throw Distance (d)10ft
3.0m
Field Diameter10.2ft
3.1m
Illuminance (fc)37816895611
Illuminance (lux)4,0711,8091,01865110.76
To determine center beam illumination in footcandles at any throw distance, divide
candela by the throw distance squared
For field diameter at any distance, multiply distance by 1.021
For beam diameter at any distance, multiply by 0.562
15ft
4.6m
15.3ft
4.7m
Beam
Lumens
20ft
6.1m
20.4ft
6.2m
Power
Consumption
25ft
194.5ft
7.6m
25.5ft
7.8m
Lumens
Per Watt
59.3m
–
40000
32000
24000
Candela
16000
8000
0
-30-20-100102030
Degrees
Iso-Illuminance Diagram
(Flat Surface Distribution)
Candela Plot
X
Y
10%
50%
% illuminance
foot candle
or lux
Source 4WRD PAR 80CRI with XWFL Lens
ModeDegree CandelaField
Lumens
XWFL62.321,8206,1602,08515539.7
Metric conversions: For meters, multiply feet by 0.3048
For lux, multiply footcandles by 10.76
29.762.3
Throw Distance (d)10ft
3.0m
Field Diameter12.1ft
3.7m
Illuminance (fc)2189755351
Illuminance (lux)2,3491,04458737610.76
To determine center beam illumination in footcandles at any throw distance, divide
candela by the throw distance squared
For field diameter at any distance, multiply distance by 1.209
For beam diameter at any distance, multiply by 0.530
15ft
4.6m
18.1ft
5.5m
Beam
Lumens
20ft
6.1m
24.2ft
7.4m
Power
Consumption
25ft
147.7ft
7.6m
30.2ft
9.2m
Lumens
Per Watt
45.0m
–
Candela Plot
25000
20000
15000
Candela
10000
5000
0
-50 -40 -30 -20 -1001020 30 4050
Degrees
X
Y
Iso-Illuminance Diagram
(Flat Surface Distribution)
10%
50%
% illuminance
foot candle
or lux
7 of 14
ETC
Field Angle
Beam Angle
Field Angle
Beam Angle
®
PHOTOMETRICS
Source 4WRD PAR/PARNel Fixture Body
Source 4WRD Series
Source 4WRD PARNel 80CRI Spot
ModeDegree CandelaField
Lumens
PARNel
80CRI Spot
Metric conversions: For meters, multiply feet by 0.3048
24.9150,9007,5203,49015548.5
For lux, multiply footcandles by 10.76
12.224.9
Throw Distance (d)10ft
3.0m
Field Diameter4.4ft
1.3m
Illuminance (fc)1,5096713772411
Illuminance (lux)16,2437,2194,0612,59910.76
To determine center beam illumination in footcandles at any throw distance, divide
candela by the throw distance squared
For field diameter at any distance, multiply distance by 0.442
For beam diameter at any distance, multiply by 0.214
15ft
4.6m
6.6ft
2.0m
Beam
Lumens
20ft
6.1m
8.8ft
2.7m
Power
Consumption
25ft
388.5ft
7.6m
11.0ft
3.4m
118.4m
–
Lumens
Per Watt
Candela Plot
160000
120000
80000
Candela
40000
0
-15-10-5051015
Degrees
Iso-Illuminance Diagram
(Flat Surface Distribution)
X
Y
10%
50%
% illuminance
foot candle
or lux
Source 4WRD PARNel 80CRI Flood
ModeDegree CandelaField
Lumens
PARNel
80CRI Flood
Metric conversions: For meters, multiply feet by 0.3048
45.644,1008,8305,18015557.0
For lux, multiply footcandles by 10.76
29.045.6
Throw Distance (d)10ft
3.0m
Field Diameter8.4ft
2.6m
Illuminance (fc)441196110711
Illuminance (lux)4,7472,1101,18776010.76
To determine center beam illumination in footcandles at any throw distance, divide
candela by the throw distance squared
For field diameter at any distance, multiply distance by 0.841
For beam diameter at any distance, multiply by 0.517
15ft
4.6m
12.6ft
3.8m
Beam
Lumens
20ft
6.1m
16.8ft
5.1m
Power
Consumption
25ft
210.0ft
7.6m
21.0ft
6.4m
64.0m
–
Lumens
Per Watt
Candela Plot
40000
32000
24000
Candela
16000
8000
0
-30-20-100102030
Degrees
X
Y
Iso-Illuminance Diagram
(Flat Surface Distribution)
10%
50%
% illuminance
foot candle
or lux
8 of 14
ETC
Field Angle
Beam Angle
Field Angle
Beam Angle
®
PHOTOMETRICS
Source 4WRD PAR/PARNel Fixture Body
Source 4WRD Series
Source 4WRD PAR 90CRI with AR Coated Flat Lens
ModeDegree CandelaField
Lumens
AR Coated
Flat
Metric conversions: For meters, multiply feet by 0.3048
19.2223,0006,8303,11015544.1
For lux, multiply footcandles by 10.76
9.219.2
Throw Distance (d)10ft
3.0m
Field Diameter3.4ft
1.0m
Illuminance (fc)2,2309915583571
Illuminance (lux)24,00310,6686,0013,84110.76
To determine center beam illumination in footcandles at any throw distance, divide
candela by the throw distance squared
For field diameter at any distance, multiply distance by 0.338
For beam diameter at any distance, multiply by 0.161
15ft
4.6m
5.1ft
1.5m
Beam
Lumens
20ft
6.1m
6.8ft
2.1m
Power
Consumption
25ft
472.2ft
7.6m
8.5ft
2.6m
143.9m
–
Lumens
Per Watt
Candela Plot
250000
200000
150000
Candela
100000
50000
0
-15-10-5051015
Degrees
Iso-Illuminance Diagram
(Flat Surface Distribution)
X
Y
10%
50%
% illuminance
foot candle
or lux
Source 4WRD PAR 90CRI with VSNP Lens
ModeDegree CandelaField
Lumens
VSNP20.0178,4006,1302,87015539.5
Metric conversions: For meters, multiply feet by 0.3048
For lux, multiply footcandles by 10.76
10.120.0
Throw Distance (d)10ft
3.0m
Field Diameter3.5ft
1.1m
Illuminance (fc)1,7847934462851
Illuminance (lux)19,2038,5354,8013,07210.76
To determine center beam illumination in footcandles at any throw distance, divide
candela by the throw distance squared
For field diameter at any distance, multiply distance by 0.353
For beam diameter at any distance, multiply by 0.177
15ft
4.6m
5.3ft
1.6m
Beam
Lumens
20ft
6.1m
7.1ft
2.1m
Power
Consumption
25ft
422.4ft
7.6m
8.8ft
2.7m
128.7m
Lumens
Per Watt
–
Candela Plot
200000
150000
100000
Candela
50000
0
-15-10-5051015
Degrees
Iso-Illuminance Diagram
(Flat Surface Distribution)
X
Y
10%
50%
% illuminance
foot candle
or lux
9 of 14
ETC
Field Angle
Beam Angle
Field Angle
Beam Angle
80000
®
PHOTOMETRICS
Source 4WRD PAR/PARNel Fixture Body
Source 4WRD Series
Source 4WRD PAR 90CRI with NSP Lens
ModeDegree CandelaField
Lumens
NSP20.7169,4006,1702,86015539.8
Metric conversions: For meters, multiply feet by 0.3048
For lux, multiply footcandles by 10.76
10.520.7
Throw Distance (d)10ft
3.0m
Field Diameter3.7ft
1.1m
Illuminance (fc)1,6947534242711
Illuminance (lux)18,2348,1044,5592,91710.76
To determine center beam illumination in footcandles at any throw distance, divide
candela by the throw distance squared
For field diameter at any distance, multiply distance by 0.365
For beam diameter at any distance, multiply by 0.184
15ft
4.6m
5.5ft
1.7m
Beam
Lumens
20ft
6.1m
7.3ft
2.2m
Power
Consumption
25ft
411.6ft
7.6m
9.1ft
2.8m
125.5m
Lumens
Per Watt
–
Candela Plot
200000
150000
100000
Candela
50000
0
-15-10-5051015
Degrees
Iso-Illuminance Diagram
(Flat Surface Distribution)
X
Y
10%
50%
% illuminance
foot candle
or lux
Source 4WRD PAR 90CRI with MFL Lens
ModeDegree CandelaField
Lumens
MFL34.668,6006,1603,56015539.7
Metric conversions: For meters, multiply feet by 0.3048
For lux, multiply footcandles by 10.76
20.634.6
Throw Distance (d)10ft
3.0m
Field Diameter6.2ft
Illuminance (fc)6863051721101
Illuminance (lux)7,3843,2821,8461,18110.76
To determine center beam illumination in footcandles at any throw distance, divide
candela by the throw distance squared
For field diameter at any distance, multiply distance by 0.623
For beam diameter at any distance, multiply by 0.363
1.9m
15ft
4.6m
9.3ft
2.8m
Beam
Lumens
20ft
6.1m
12.5ft
3.8m
Power
Consumption
25ft
261.9ft
7.6m
15.6ft
4.7m
79.8m
–
Lumens
Per Watt
Candela Plot
60000
40000
Candela
20000
0
-30-20-100102030
Degrees
Iso-Illuminance Diagram
(Flat Surface Distribution)
X
Y
10%
50%
% illuminance
foot candle
or lux
10 of 14
ETC
Field Angle
Beam Angle
Field Angle
Beam Angle
®
PHOTOMETRICS
Source 4WRD PAR/PARNel Fixture Body
Source 4WRD Series
Source 4WRD PAR 90CRI with WFL Lens
ModeDegree CandelaField
Lumens
WFL54.129,1005,9203,10015538.2
Metric conversions: For meters, multiply feet by 0.3048
For lux, multiply footcandles by 10.76
31.254.1
Throw Distance (d)10ft
3.0m
Field Diameter10.2ft
3.1m
Illuminance (fc)29112973471
Illuminance (lux)3,1321,39278350110.76
To determine center beam illumination in footcandles at any throw distance, divide
candela by the throw distance squared
For field diameter at any distance, multiply distance by 1.021
For beam diameter at any distance, multiply by 0.558
15ft
4.6m
15.3ft
4.7m
Beam
Lumens
20ft
6.1m
20.4ft
6.2m
Power
Consumption
25ft
170.6ft
7.6m
25.5ft
7.8m
Lumens
Per Watt
52.0m
–
32000
24000
16000
Candela
8000
0
-30-20-100102030
Degrees
Iso-Illuminance Diagram
(Flat Surface Distribution)
Candela Plot
X
Y
10%
50%
% illuminance
foot candle
or lux
Source 4WRD PAR 90CRI with XWFL Lens
ModeDegree CandelaField
Lumens
XWFL62.216,7204,7301,64015530.5
Metric conversions: For meters, multiply feet by 0.3048
For lux, multiply footcandles by 10.76
30.162.2
Throw Distance (d)10ft
3.0m
Field Diameter12.1ft
3.7m
Illuminance (fc)1677442271
Illuminance (lux)1,80080045028810.76
To determine center beam illumination in footcandles at any throw distance, divide
candela by the throw distance squared
For field diameter at any distance, multiply distance by 1.206
For beam diameter at any distance, multiply by 0.538
15ft
4.6m
18.1ft
5.5m
Beam
Lumens
20ft
6.1m
24.1ft
7.4m
Power
Consumption
25ft
7.6m
30.2ft
9.2m
129.3ft
Lumens
Per Watt
39.4m
–
Candela Plot
20000
15000
10000
Candela
5000
0
-50 -40 -30 -20 -10010 2030 4050
Degrees
X
Y
Iso-Illuminance Diagram
(Flat Surface Distribution)
10%
50%
% illuminance
foot candle
or lux
11 of 14
ETC
Field Angle
Beam Angle
Field Angle
Beam Angle
®
PHOTOMETRICS
Source 4WRD PAR/PARNel Fixture Body
Source 4WRD Series
Source 4WRD PARNel 90CRI Spot
ModeDegree CandelaField
Lumens
PARNel
90CRI Spot
Metric conversions: For meters, multiply feet by 0.3048
25.3111,9005,7302,59015537.0
For lux, multiply footcandles by 10.76
12.325.3
Throw Distance (d)10ft
3.0m
Field Diameter4.5ft
1.4m
Illuminance (fc)1,1194972801791
Illuminance (lux)12,0455,3533,0111,92710.76
To determine center beam illumination in footcandles at any throw distance, divide
candela by the throw distance squared
For field diameter at any distance, multiply distance by 0.449
For beam diameter at any distance, multiply by 0.216
15ft
4.6m
6.7ft
2.1m
Beam
Lumens
20ft
6.1m
9.0ft
2.7m
Power
Consumption
25ft
334.5ft
7.6m
11.2ft
3.4m
102.0m
–
Lumens
Per Watt
Candela Plot
120000
90000
60000
Candela
30000
0
-15-10-5051015
Degrees
Iso-Illuminance Diagram
(Flat Surface Distribution)
X
Y
10%
50%
% illuminance
foot candle
or lux
Source 4WRD PARNel 90CRI Flood
ModeDegree CandelaField
Lumens
PARNel
90CRI Flood
Metric conversions: For meters, multiply feet by 0.3048
46.030,9006,6203,82015542.7
For lux, multiply footcandles by 10.76
29.046.0
Throw Distance (d)10ft
3.0m
Field Diameter8.5ft
2.6m
Illuminance (fc)30913777491
Illuminance (lux)3,3261,47883253210.76
To determine center beam illumination in footcandles at any throw distance, divide
candela by the throw distance squared
For field diameter at any distance, multiply distance by 0.623
For beam diameter at any distance, multiply by 0.363
15ft
4.6m
12.7ft
3.9m
Beam
Lumens
20ft
6.1m
17.0ft
5.2m
Power
Consumption
25ft
175.8ft
7.6m
21.2ft
6.5m
53.6m
–
Lumens
Per Watt
Candela Plot
32000
24000
16000
Candela
8000
0
-30-20-100102030
Degrees
X
Y
Iso-Illuminance Diagram
(Flat Surface Distribution)
10%
50%
% illuminance
foot candle
or lux
12 of 14
ETC
®
Source 4WRD PAR/PARNel Fixture Body
ADDITIONAL ORDERING INFORMATION
Accessories
MODELDESCRIPTION
S4WRD Source 4WRD Retrofit Kit
S4WRDGSource 4WRD Gallery (90+ CRI) Retrofit Kit
407CFColor frame (7.5”) (included)
400SCSafety Cable
400CCC-Clamp
400–VNSPVery Narrow Spot lens
400–NSPNarrow Spot lens
400–MFLMedium Flood lens
400–WFLWide Flood lens
400–LS4Set of four Source Four PAR lenses (VNSP, NSP, MFL, WFL)
400-XWFLExtra Wide Flood lens
400PTH3Top hat, 3”
400PTH6Top hat, 6”
400PHHHalf hat
400XBTHCross baffle top hat
400BDBarn door
400LEgg crate louver
400WBWeighted base
Source 4WRD Series
NOTES ABOUT LED LUMINAIRES
All LED sources experience some lessening of light output and some color shift over time. LED output will vary with thermal conditions. Thermal
conditions can be affected by ambient temperatures and orientation. Based on the LED manufacturer’s B50 L70 specification, a Source 4WRD
luminaire will achieve ~70% of its initial output after an estimated 30,000 hours of typical usage*. In individual situations, LEDs will be used for
different durations and at different levels. This can eventually lead to minor alterations in color performance, necessitating slight adjustments to
presets, cues or programs.
*Note: Life tests are currently underway. Results are pending.
13 of 14
ETC
®
Source 4WRD PAR/PARNel Fixture Body
Source 4WRD Series
PHYSICAL
Source 4WRD PAR Dimensions
MODELHEIGHTWIDTHDEPTH
inchesmminchesmminchesmm
4WRD PAR11.0428010.6327012.79325
4WRD PARNel 11.6829610.6327012.79325
Source 4WRD PAR Weights
MODELWEIGHT*SHIPPING WEIGHT WEIGHT WITH S4WRD LED*