ETC SmartPack CE Terminal Output Panel User Manual

ETC® Setup Guide
SmartPack® with Terminal Output Panel
This Setup Guide contains installation instructions for the SmartPack® with Terminal Output Panel. If you have any questions, please contact the supplier of your ETC equipment or ETC Technical Services.
ETC Americas: Tel: +1 800 688 4116 (toll-free within USA)
Tel: +1 608 831 4116 (from outside USA) Email: service@etcconnect.com
ETC Asia: Tel: +852 2799 1220
Email: service@etcasia.com
ETC Europe: Tel: +44 (0)20 8896 1000
Email: service@etceurope.com
Model Number Voltage Model Number Voltage
SH615TM 230V SN615TM 230V ND
SH1210TM 230V SN1210TM 230V ND
Installation Instructions
Step 1: Terminate conductors.
a: To prepare the load conductors, strip 12-13mm (.49”) of insulation from the end of each wire.
To prepare the input conductors, strip 16-17mm (.65”) of insulation from the end of each wire.
b: Insert the Wago terminal tool (Wago #210-141) into the terminal (input terminal shown), or
you can use a screwdriver if the Wago tool is unavailable.
- OR -
Americas
 3030 Laura Lane, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA  Tel: +608 831 4116  +800 688 4116  Fax: +608 836 1736  +800 555 8912
Europe
 Unit 5, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK  Tel: +44 (0)20 8896 1000  Fax: +44 (0)20 8896 2000
Asia
 Room 605-606, Tower III Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong  Tel: +852 2799 1220  Fax: +852 2799 9325
Web
: www.etcconnect.com
Service
: (US) service@etcconnect.com  (UK) service@etceurope.com  (Asia) service@etcasia.com Comments about this document: Copyright © 2003 Electronic Theatre Controls, Inc. All Rights Reserved. Product information and specifications subject to change. Tous droits réservés. Toutes informations et spécifications techniques susceptibles d'être modifiées. Alle Rechte vorbehalten. Bei Produkt Informationen und Eigenschaften sind Änderungen vorbehalten. Todos derechos reservados. Información y especificaciones del producto sujetos a cambio.
7020M2210
 Rev A  9/2003
Email
: (US) mail@etcconnect.com  (UK) mail@etceurope.com  (Asia) mail@etcasia.com
Commentaires:  Anmerkungen:  Comentarios sobre este documento: techcomm@etcconnect.com
c: To open the terminal, squeeze the handles of the Wago terminal tool until it clicks. If you are
using a screwdriver, align the head with the slot in the top of the terminal and press down firmly until the terminal opens.
d: Insert the prepared wire into the terminal (input terminal shown):
e: Squeeze and release the handles of the Wago terminal tool, or remove the screwdriver. The
wire should be held securely in the terminal.
f: Repeat for all earth/ground, neutral and hot wires for each load circuit, and for all input
wiring.
Wiring Diagrams
Keep area free of obstructions.
12 Channel Models
6 Channel Models
Neutral
Keep area free of obstructions.
Live
Neutral
Live
40A MAX PER CONNECTION
40A MAX PER CONNECTION