ETC’s Desire D22 is designed for indoor installations and has a rugged die-cast enclosure, steel mounting yoke, and noise-free, fan-less operation.
The D22 can be pipe mounted with a C-clamp, canopy mounted, or track mounted. Mounting accessories are available. Contact ETC Customer Service for assistance; contact information is located at the bottom of this page.
For information about the operation of the D22 Desire Series, refer to Desire Series by ETC D22, D40, D40XT, D60 User Manual. ETC manuals are available for download at http://www.etcconnect.com/downloads.aspx
.
CAUTION:
Do not attempt to install or use a fixture until you read and understand the installation instructions and safety labels.
WARNING:
This fixture must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations.

Specifications

Environment

Operates in ambient temperatures of 0°C to +40°C (32°F to 104°F).
CAUTION:
Corporate Headquarters London, UK
 Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK  Tel +44 (0)20 8896 1000  Fax +44 (0)20 8896 2000
Rome, IT 
Via Pieve Torina, 48, 00156 Rome, Italy  Tel +39 (06) 32 111 683  Fax +44 (0)20 8752 8486
Holzkirchen, DE Hong Kong  Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong  Tel +852 2799 1220 Service:
(Americas) service@etcconnect.com
Web:
www.etcconnect.com
7411M2100
 Rev C  Released 2013-11  ETC intends this document to be provided in its entirety.
Desire D22 Page 1 of 8 Electronic Theatre Controls, Inc.
 3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA  Tel +608 831 4116  Fax +608 836 1736
 Ohmstrasse 3, 83607 Holzkirchen, Germany  Tel +49 (80 24) 47 00-0  Fax +49 (80 24) 47 00-3 00
Copyright © 2013 ETC. All Rights Reserved.  Product information and specifications subject to change.
Risk of eye injury. Do not stare directly into the light. Do not operate in proximity to flammable materials.
(UK) service@etceurope.com  (DE) techserv-hoki@etcconnect.com
(Asia) service@etcasia.com

Control

Portable

The Portable D22 is provided with 5-pin XLR connectors on the back for in and thru connection to a DMX/RDM control network.

Canopy Mount

The D22 Canopy Mount fixture is provided with one cable, which provides power and data into the canopy.
A termination board is incorporated into the mounting plate for installation onto a voltage-separated junction box (junction box provided by others, voltage barrier provided by ETC) and provides termination for control wiring.
• Connection of the D22 data cable to a provided screw-down connector, which is pre-wired at the factory. The connector is plugged into the termination board. The braided shield is connected inside the fixture and should not be connected in the canopy.
• Connection of DMX/RDM input from the control source. This connection can be cable type Belden 9729 (or equivalent) to the provided screw terminal. When using Cat5 (or equivalent) cable type for DMX/RDM input, order a Cat5 termination kit from ETC (part number 4100A1013). Cat5 termination instructions and an IDC connector are provided with the termination kit.
• Connection of DMX/RDM thru to the next DMX device. This connection may also be either Belden 9729 or Cat5. The connector is not provided. Order the appropriate DMX termination kit for the cable type used from ETC (Belden 9729 use 4100A1012 or Cat5 use 4100A1013). Termination instructions and the appropriate connector is provided with the termination kit. Up to 32 DMX/ RDM devices can be daisy-chained together per data run.

Track Mount

The Track Mount fixture’s power and data connections are made through the Eutrac MultiAdaptor mounting adapter. No further wiring to the fixture is required. Refer to the track installation instructions for more information.
2 Desire Series D22

Electrical

WARNING:
The Desire D22 Portable is provided with a permanently installed power cord with 3-prong Edison connector. Region specific connectors are available. Contact ETC for available options. The Canopy fixture is provided with power and data wired to the canopy and should be terminated in a voltage-separated junction box (provided by others). The Track mount receives power through its MultiAdaptor, which connects to one of two circuits.
Ensure the main power supply is off before installing or wiring a fixture.

Power Requirements

The universal power supply accepts 100-240 VAC 50/60Hz.
CAUTION:
Note:
Do not use a fixture for any voltage for which it is not rated. Do not exceed the specified voltage and current input for any fixture.Connecting the fixture to a voltage outside the acceptable range may damage the unit and will void the factory warranty.
The fixture must be grounded. Application appropriate electrical junction box with cord grips
are required. A voltage-separated junction box is required. A RACO 232 series 4 x 2-1/8 inch deep junction box is recommended.The junction box must not interfere with fixture focusing.
The fixture is factory pre-wired. Opening the housing is not required.
The fixture must be connected to a non-dimmable power source. Dimming the unit will damage the fixture and void the factory warranty.
Power Connections
Mains Europe North America
Line Brown Black
Neutral Blue White
Ground Green/Yellow Green