ETC D22 Portable, Desire Series, D60, D60X, D40 Quick Manual

...
ETC Quick Guide
LED array
Accessory holder
Yoke
Accessory retainer
Yoke locking
Safety cable loop
PUSH
Power In
Power Thru
Keypad
LCD
DMX In
DMX Thru
Status indicators
***There is no user interface on the D60X
Light Bulb
Home
Back
Up
Enter
Down
Power – Indicates AC power is On. DMX – Indicates control signal is Active. Error – Indicates data error, high temperature, or other unusual status.
Desire® Fixture Series

Overview

For complete information and step-by-step instructions, see Desire Series by ETC D22, D40, D40XT, D60, D60X User Manual. ETC documentation can be downloaded at www.etcconnect.com/downloads.aspx
The features shown in the following graphics may not appear on all Desire Series fixtures.
.
Corporate Headquarters  Middleton, WI, USA  Tel +608 831 4116  Service: (Americas) service@etcconnect.com London, UK Rome, IT Holzkirchen, DE Hong Kong Web: www.etcconnect.com
7410M1300-1.8.0
D22, D40, D40XT, D60, D60X Fixtures Page 1 of 12 Electronic Theatre Controls, Inc.
Tel +44 (0)20 8896 1000  Service: (UK) service@etceurope.com
Tel +39 (06) 32 111 683  Service: (UK) service@etceurope.com
Tel +49 (80 24) 47 00-0  Service: (DE) techserv-hoki@etcconnect.com
Tel +852 2799 1220  Service: (Asia) service@etcasia.com
Rev A  Released 2015-10  ETC intends this document to be provided in its entirety.
© 2015 ETC. All Rights Reserved.  Product information and specifications subject to change.
ETC Quick Guide
With yoke
Accessory holder and clip
With floor stand
Canopy mount
(D22 only)
Track mount
(D22 only)
PUSH
Power In
DMX In
DMX Thru
Power Thru (Power Thru not available on D22)
***There’s no UI on D60X
Desire Fixture Series

Install

D22 Portable, D40, D40XT, D60, D60X

Step 1: Hang or mount the fixture. Step 2: Attach safety cable. Step 3: Insert secondary lens with smooth side out, if desired. Step 4: Insert additional accessories if desired. (top hat, egg crate, etc.)
WARNING:
Use only hardware rated for total weight of fixture and accessories.
The safety cable (or other approved safety device) must be securely attached to the safety cable loop before loosening the clamp.

D22 Canopy and D22 Track

See the Desire Series D22 Installation Guide for details on installing the Canopy and Track mounted options of the D22 fixture.

Connect

D22 Portable, D40, D40XT, D60 and D60X

Step 1: If using external DMX or RDM control, attach a 5-pin XLR cable to DMX In. Step 2: Connect power cable to AC power. Step 3: Plug the XLR cable into data source, if applicable. Step 4: Link any additional fixtures via Power Thru and DMX Thru connectors.
• The D22 fixture does not have the Power Thru option.
WARNING:
D22, D40, D40XT, D60, D60X Fixtures Page 2 of 12 Electronic Theatre Controls, Inc.
• Do not link more than nine fixtures when using Power Thru (non-dimming, 100 to 240 VAC, 50/60 Hz). Power Thru is not available on all Desire Series fixtures.
• Up to 32 devices can be daisy-chained together per data run.
• Disconnect Power and DMX before all cleaning and maintenance.
ETC Quick Guide
Desire Fixture Series
Note:

Focus

D60X fixtures do not have the user interface that other Desire fixtures do. For information on setting up D60X fixtures, skip to:
Configure D60X using RDM on page 4.
Step 1: Supply power and wait for the
Step 2: Press [] to open Presets &
Step 3: Select Focus and press []
Step 4: Adjust fixture's position.
Step 5: Once focus is set, press [] to turn off LED array and then [] to return to home screen.

Address

Step 1: From the home screen, press [] to open Main Menu.
Step 2: On the Main Menu, scroll to DMX Start Address, press [].
For setup of D22 track and canopy mounted fixtures, see the D22 Installation Guide. ETC documentation can be downloaded at www.etcconnect.com.
fixture to boot up.
Sequences.
to turn on LED array.
Step 3: Use [] or [] to scroll to desired address.
Step 4: Press [] to select address number.
Step 5: Press [] to return to home screen.
* DMX address is not needed if using standalone or master/slave control.

Features Quick Setup

Step 1: On the Main Menu, scroll to Quick Setups.
Step 2: Press [].
Step 3: Scroll to the desired setup and then press [].
An asterisk (*) indicates which setup is active.
• Press [] to return to the home screen. The top line of the home screen displays the name of the active setup.
Individual features and settings are adjustable under the Advanced menu. Consult the User Manual for more information on advanced features of Desire fixtures.
D22, D40, D40XT, D60, D60X Fixtures Page 3 of 12 Electronic Theatre Controls, Inc.
ETC Quick Guide
D60X fixture
Desire Fixture Series

Quick Color (Vivid, Lustr+, Fire and Ice, Studio HD)

Quick Color allows you to easily select a color and its intensity from a predefined menu. This feature overrides any presets or sequences previously selected and is only available when there is no external DMX signal to the fixture.
Note:
To select a Quick Color:
Step 1: Press the [] to access the Presets and Sequences screen.
Step 2: Within the Presets and Sequences screen, scroll to Quick Color and press [].
Step 3: Scroll to Color and press [].
Step 4: Scroll to the desired color and press [].
Step 5: Scroll to adjust the fixture’s intensity and press [] to commit the selection.
Step 6: To exit the Quick Color menu, press [].
Exiting the Quick Color menu will return the fixture to the state it was in prior to entering the menu.

Configure D60X using RDM

Up to 32 D60X fixtures can be daisy-chained on a DMX/RDM network. Each fixture can have an unique DMX address and each address can be configured separately. Also, more that one fixture can have the same address, allowing you to configure them identically.
Use an RDM configuration tool or an RDM lighting control device to configure the fixtures. An RDM configuration tool is installed on a PC, which is connected to the DMX/RDM network via Gadget or a DMX/RDM gateway. After the fixtures are configured, Gadget or the gateway can be disconnected and a DMX or RDM control device can be connected to the network for continued operation. For more information on configuring fixtures using RDM, reference the Desire Series User Manual. All manuals are available for free download from www.etcconnect.com
.
D22, D40, D40XT, D60, D60X Fixtures Page 4 of 12 Electronic Theatre Controls, Inc.