Acceptable voltage is 120V (+/- 10%) 50/60HZ only .
Operating current of 1.5 Amps
Inrush current of <14 Amps
Room ambient temperature should not exceed 104ºF (40ºC)
Lamp ignition voltage is 4.5Kv, non-hot restrike.
Ballast case temperature should not exceed 167ºF (75ºC)
The ballast is attached to the Source Four yoke by two screws, non-remotable.
Source Four™ HID • 1
3.
Figure 1
HID Lamp
Lamp base
Lamp housing
Figure 2
Beam focus knob
1.
2.
4.
5.
6.
1.
2.
3.
Installing or replacing the lamp
A lamp must be installed before you use the fixture.
Note:
Verify that the lamp you intend to install is correct.
Replace the lamp if it becomes damaged or thermally deformed.
WARNING!
Disconnect power to the Source Four HID before installing the lamp.
Loosen the knurled bolt on the back of the lamp housing and pull the housing
out.
Holding it by the base, remove the lamp from its box.
Note:
Insert lamp base into socket assembly as show in Figure 1 .
Push down on the lamp base until the lamp seats firmly.
Caution! Improperly installed lamps cause premature lamp failure and socket
problems.
Reinstall the lamp housing by aligning the bolt hole and tightening the knurled
bolt.
Let the lamp cool before replacing.
To avoid premature lamp failure, do not touch the lamp glass. If you do,
clean it carefully with rubbing alcohol and a clean lint-free cloth before
operation.
Focusing the beam
Loosen the beam focus knob located under the barrel as shown in Figure 2 .
Slide the lens tube forward or backward to achieve the desired beam edge.
Once the fixture is focused, tighten the beam focus knob.
2 • Source Four™ HID
4.
5.
1.
2.
1.
2.
3.
3.
Color frame retaining clip
The color frame holder is equipped with a spring-loaded retaining clip that prevents color
frames and accessories from falling out ( Figure 3 ).
WARNING!
position with the retaining clip before hanging the Source Four HID.
Release the retaining clip by pushing it sideways while gently pulling backwards.
Insert the color frame.
Lock the retaining clip by pushing sideways while gently pushing forward.
Make sure all color frame accessories are locked in
Shaping the beam
You may shape the beam with the shutters, a pattern, an optional drop-in iris, or by
rotating the barrel.
Pattern projection
The pattern holder slot is on the top side of the barrel and in front of the shutters. It
accommodates A-size, B-size and glass pattern holders ( Figure 4 ).
Note:
Because the Source Four HID gate is 3.12 inches. ETC recommends using
A-size patterns for maximum pattern effectiveness.
Use an optional donut in the accessory holder to enhance pattern projection. Donut
diameter range should be 2.5 to 2.75 inches.
Drop-in iris slot
The drop-in iris slot is located on the top of the barrel and in front of the pattern holder
slot. It accommodates either a drop-in iris or a motorized pattern device. When the slot is
not in use, a small sheet metal cover secured with two Phillips screws prevents light
leakage ( Figure 5 ).
Use a Phillips screwdriver to loosen the screws on the drop-in iris slot cover. Do
not remove the screws.
Slide the cover completely forward to expose the slot.
Insert the iris or motorized pattern device. For an iris, install the flat side toward
the shutters and make sure that the iris handle extends from the slot.
Slide the slot cover back toward the shutters until it meets the iris handle. Leave
enough space to move the iris handle.
Secure the drop-in iris slot cover by tightening the screws.
Pattern holders
A-size holds 3” diameter patterns
3.12" dia.
3.70"
Drop-in iris slot
Retaining clip in the
locked position
B-size holds 2.75” and
2.5” diameter patterns
2.75" dia.
3.70"
Figure 3
Figure 4
Iris
Figure 5
Source Four™ HID • 3
Figure 6
Barrel rotation knob
Figure 9
1.
2.
3.
Rotating the barrel assembly
Loosen the barrel rotation knob directly behind the shutters on the underside of
the reflector housing ( Figure 6 ). Do not remove the barrel rotation knob.
Rotate the barrel to the desired position (up to 25° in either direction from the
centered position).
Once the barrel is positioned, tighten the barrel's rotation knob to lock it into
position.
C-clamp mounting instructions (C-clamp not included)
The C-clamp attaches the fixture to the mounting pipe and allows you to adjust the
position of the fixture once it is mounted ( Figure 7 ).
Tightly fasten the C-clamp to the yoke with the provided yoke bolt and lock
washer.
Insert and tighten the Pan screw.
Note : A Canopy mounting option is also available.
Adjusting the C-clamp
The C-clamp attaches the fixture to the mounting pipe and allows you to adjust the
position of the fixture once it is mounted ( Figure 7 ).
Place the C-clamp on mounting pipe, then tighten the pipe bolt to secure it.
Loosen the C-clamp pan screw and rotate the yoke to the desired position.
Tighten the pan screw to lock the fixture into position.
1.
2.
1.
2.
Yoke bolt and
lock washer
3.
Pan screw
1.
2.
3.
4.
1.
2.
3.
C-clamp
E T C
Pipe bolt
Yoke
Adjusting the yoke position
The Source Four HID provides multi-positioning capabilities within its yoke for overall
fixture height and angle.
Setting the fixture height within the yoke
The Source Four HID has a two-position yoke for modifying the overall height in which
the fixture is mounted ( Figure 8 ). To change the height position, do the following:
Remove the yoke locking knobs, washers, and hex bolts from either side of the
fixture.
Raise or lower the fixture to the desired position within the yoke.
Replace the yoke’s hex bolts, washers, and locking knobs.
Tighten the yoke knobs to secure the fixture in position.
Setting the angle within the yoke
Loosen the yoke locking knobs. ( Do not remove them.)
Tilt the fixture to the desired position ( Figure 9 ).
Tighten the yoke locking knobs to secure the fixture in position.
Figure 7
High position
Low position
Figure 8
4 • Source Four™ HID
Cleaning
ETC offers the following recommendations when cleaning and inspecting lenses and
reflectors:
Do not use glass or window type cleaners on lenses (glass or polymer) or reflectors.
Do not use abrasive materials such as steel wool.
Replace lenses if they contain visible damage (cracks or deep scratches) that may impair
their effectiveness.
Cleaning 19°, 26°, 36°, and 50° glass lenses
Remove the beam focus knob at the bottom of the barrel. Remove the lens tube
from the barrel.
Note:
It is not necessary to remove the lens for cleaning. If you do remove the
19°, 26°, or 50° lens, make sure the identifying paint dot is not removed
during cleaning. See “Lens Locations” below.
Dampen a clean lint-free cloth with vinegar or household ammonia. You may also
use water, but it will leave spots that can be removed by gently polishing the lens
with a clean and dry cloth.
Starting from the center, gently wipe the lens.
Slide the lens tube back into the barrel with the color frame retaining clip on top.
Replace the beam focus knob.
5.
6.
7.
1.
2.
3.
4.
1.
2.
3.
4.
Cleaning 5° and 10° polymer lenses
To quickly clean the lenses, remove dust with a blast of oil-free air. If this is not sufficient,
follow the instructions below. You will need a Phillips screwdriver.
Caution! Handle polymer lenses by their edges only. Never rub anything dry on a
polymer lens.
Remove the beam focus knob. Gently pull the lens tube out of the barrel.
Use a Phillips screwdriver to remove the brackets that hold the lens in place.
Remove the lens from the tube.
Dip the lens in a clean alcohol/water mixture (10% alcohol).
Use a moistened nylon bristle brush to wash the lens' smooth side in a linear
(non-circular) motion.
Use the same brush to lightly wash the lens' ridged side by following its ridges.
Dip the lens in a clean alcohol/water mixture (10% alcohol).
Dry the smooth and ridged surfaces with an air gun. Make sure that the air flow
moves liquid away from you.
8. Inspect the lens for dirt. Repeat steps 3-7 if necessary.
9. Set the lens back in the lens tube with the ridged side facing the front of the
tube. Replace the lens brackets.
10.Slide the lens tube back into the barrel with gel frame retainer on top. Replace
beam focus knob.
Lens locations
The different lenses used in the Source
Four are not interchangeable. When
installing a new lens, refer to the adjacent
illustration for proper placement. Also,
remember to have the lens’ color
designator dot facing the color frame.
19° (6x16)
Red dot
26° (6x12)
Black dot
36° (6x9)
Dotless
50° (4.5x6)
Yellow dot
Figure 10
Source Four™ HID • 5
Cleaning the reflector
WARNING!
To quickly clean the reflector, remove the lens tube and clean the dust from the reflector
with a blast of oil-free air. You may also wipe the reflector with a clean lint-free cloth. If
either method is not sufficient, follow the instructions below. You will need a Phillips
screwdriver to complete this procedure.
1. Remove the barrel rotation knob located at the bottom of the barrel. Use a
2. Rotate the barrel 45° in either direction. Carefully remove the barrel from the
3. Dampen a clean lint-free cloth with alcohol or distilled water. (Alcohol is
4. Gently wipe the reflector.
5. Insert the barrel into the reflector housing with the iris/pattern slot on top. (Line
6. While pressing in gently, rotate the barrel 45° clockwise until it sets into position.
7. Replace the barrel rotation knob and tighten the retainer bolt.
Disconnect the power to the fixture before attempting to clean the reflector.
Phillips screwdriver to remove the retainer bolt located on top of the reflector
housing.
reflector housing.
recommended.)
up the triangles on both parts.)
Then, rotate the barrel counterclockwise 45°. The barrel should be firmly
attached and the triangles should line up again.
6 • Source Four™ HID
Source Four™ HID • 7
Electronic Theatre Controls
North America 3030 Laura Lane • Middleton, Wisconsin 53562 • USA • Tel: (+1) 608 831 4116 • Fax: (+1) 608 836 1736
Europe 5 Victoria Industrial Estate • Victoria Road • London W3 6UU • Tel: (+44) 181 896 1000 • Fax: (+44) 181 896 2000
Asia Room 605-606 • Tower III • Enterprise Square • 9 Sheung Yuet Road • Kowloon Bay • Hong Kong • Tel: (+852) 2799 1220 • Fax: (+852) 2799 9325
World Wide Web: http://www.etcconnect.com • Email: mail@etcconnect.com
Specifications subject to change. Source Four™ HID is protected by US patent numbers 5,345,371, 5,446,637 and 5,544,029.
Part number: 7060M1016.
Copyright 2000
Revised 03/00.