Photometric Data
Voltage Candlepower Field Lumens Efficacy LPW Efficiency %
230 287,000 11,300 15.1 58.2
240 289,000 9,290 12.4 47.9
Voltage Candlepower Field Lumens Efficacy LPW Efficiency %
230 91,200 10,700 14.3 55.2
240 88,300 10,100 13.5 52.1
15°
23°
Voltage Candlepower Field Lumens Efficacy LPW Efficiency %
230 175,000 11.800 15.7 60.8
240 157,000 10,800 14.4 55.7
30°
Voltage Candlepower Field Lumens Efficacy LPW Efficiency %
230 143,000 12,600 16.8 64.9
240 130,000 12,400 16.5 63.9
25°
36°
Voltage Candlepower Field Lumens Efficacy LPW Efficiency %
230 73,900 12,800 17.1 66.0
240 74,900 12,400 16.5 63.9
Voltage Candlepower Field Lumens Efficacy LPW Efficiency %
230 37,500 11,700 15.6 60.3
240 36,100 11,600 15.5 59.8
3 OF 4
50°
12°
17°
Beam Angle
Field Angle
22°
31°
Beam Angle
Field Angle
Field Diameter (m)
3.0 3.9 4.8 6.0
Illumination 230V (lux)2870 1698 1121 718
Illumination 240V (lux)2890 1710 1129 723
20°
27°
Beam Angle
Field Angle
26°
36°
Beam Angle
Field Angle
Source Four™Zoom
Source Four Zoom 25°- 50°
Source Four Zoom 15°- 30°
Distance (m) 5.0 7.0 9.0 11.0
Field Diameter (m) 2.8 3.9 5.0 6.2
Illumination 230V (lux)3648 1861 1126 754
Illumination 240V (lux)3532 1802 1090 730
35°
49°
Beam Angle
Field Angle
Distance (m) 3.0 4.5 5.5 6.5
Field Diameter (m)
2.8 4.1 5.0 6.0
Illumination 230V (lux)
4167 1852 1240 888
Illumination 240V (lux) 4011 1783 1193 854
Distance (m) 4.5 6.0 8.0 9.0
Field Diameter (m) 3.0 4.0 5.3 5.9
Illumination 230V (lux)
3649 2053 1155 912
Illumination 240V (lux)3699 2081 1170 925
16°
23°
Beam Angle
Field Angle
Distance (m) 7.0 10.0 12.0 15.0
Field Diameter (m) 2.9 4.1 4.9 6.2
Illumination 230V (lux)
3571 1750 1215 778
Illumination 240V (lux)3204 1570 1090 698
Distance (m)
10.0 13.0 16.0 20.0
Distance (m)
7.0 9.0 11.0 13.0
Field Diameter (m)
3.3 4.2 5.1 6.1
Illumination 230V (lux) 2918 1765 1182 846
Illumination 240V (lux) 2653 1605 1074 769
For Field diameter at any distance, multiply distance by 0.30
For Beam diameter at any distance, multiply distance by 0.21
For Field diameter at any distance, multiply distance by 0.47
For Beam diameter at any distance, multiply distance by 0.33
For Field diameter at any distance, multiply distance by 0.41
For Beam diameter at any distance, multiply distance by 0.28
For Field diameter at any distance, multiply distance by 0.66
For Beam diameter at any distance, multiply distance by 0.63
For Field diameter at any distance, multiply distance by 0.92
For Beam diameter at any distance, multiply distance by 0.63
For Field diameter at any distance, multiply distance by 0.56
For Beam diameter at any distance, multiply distance by 0.39
All photometric data in this document was prepared using standard production luminaires, and the Prometric™ measurement system. Luminaires were
adjusted for a flat field and were tested with calibrated HPL 750/230V 19,400 and HPL 750/240V 19,400 lumen lamps at their rated voltage. All data
normalised to nominal lamp lumens.
To determine illumination in footcandles or lux at any throw distance, divide candlepower by distance squared.