ETA Systems 420VA, 600VA, 800VA, 1100VA, 1440VA User Manual

ETA Systems
1450 Lakeside Drive
Waukegan, IL 60085
Phone: (330) 677-4424
Fax: (330) 677-4471
Toll Free: (800) 321-6699
On the web @ http://www.etasys.com
© 2006 ETA Systems SM 5501RevB
Uninterruptible Power Manager
420VA, 600VA, 800VA, 1100VA, 1440VA
RoHS Compliant Uninterruptible Power Supply
Managed Power
User’s Guide
Guía Del Utilizador
Le Guide De l'Utilisateur
Anleitung Des Benutzers
Guida Dell' Utente
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
CONTENTS – CONTENIDO – CONTENU – INHALT – SODDISFARE
ENGLISH
1.0 – First ..............................................................1
2.0 – Safety Issues................................................2
3.0 – FCC Issues ..................................................4
4.0 – DOC Issues.................................................. 5
5.0 – Overview ......................................................5
6.0 – Operation .....................................................7
7.0 – Unpacking, Inspection, Testing ..................12
8.0 – Battery Replacement..................................16
9.0 – Warranty.....................................................17
10.0 – Specifications ...........................................92
11.0 – Illustrations ...............................................97
12.0 – Life Support Applications .......................105
ESPAÑOLES
1.0 – Primero.......................................................19
2.0 – Seguridad................................................... 20
3.0 – FCC Información ........................................22
4.0 – DOC Información .......................................23
5.0 – Visión General............................................23
6.0 – Operación...................................................25
7.0 – Disempaque, Examen................................ 31
8.0 – Reemplazo De La Batería.......................... 35
9.0 – Garantía .....................................................36
10.0 – Especificaciones ......................................92
11.0 – Ilustraciones .............................................97
12.0 – Aplicaciones De Ayuda De la Vida.........105
FRANCAIS
1.0 – D ‘Abord .....................................................38
2.0 – Sûrete.........................................................39
3.0 – Issues De FCC........................................... 41
4.0 – Issues De DOC ..........................................42
5.0 – Vue D’Ensemble ........................................42
6.0 – Execution ...................................................44
7.0 – Eclament, Inspection, Dépannage .............49
8.0 – Remplacement De Batterie ........................52
9.0 – Garantie .....................................................54
10.0 – Caractéristiques .......................................92
11.0 – Illustrations ...............................................97
12.0 – Applications De Support De la Vie .........105
DEUTSCH
1.0 – Allgemeines ...............................................55
2.0 – Sicherheits Hinweise ................................. 56
3.0 – FCC Richtlinien.......................................... 58
4.0 – DOC Richtlinien .........................................59
5.0 – Übersicht.................................................... 59
6.0 – Bedienung.................................................. 61
7.0 – Entpacken, Kontrolle, Prüfung ................... 67
8.0 – Batterie Wiedereinbau ...............................70
9.0 – Garantie ..................................................... 72
10.0 – Spezifikationen ........................................ 92
11.0 – Abbildungen............................................. 97
12.0 – LebenUmfeldaufgaben .......................... 105
ITALIANO
1.0 – In Primo Luogo .......................................... 74
2.0 – Sicurezza ................................................... 75
3.0 – Soggetti Del FCC....................................... 77
4.0 – Sogetti Del DOC ........................................78
5.0 – Sommario .................................................. 78
6.0 – Funzionamento .......................................... 80
7.0 – Disimnballagio, Ispezione.......................... 86
8.0 – Rimontaggio Della Batteria ........................ 89
9.0 – Garanzia ....................................................91
10.0 – Specifiche ................................................92
11.0 – Illustrazioni............................................... 97
12.0 – Applicazioni Di Sostegno Di Vita ........... 105
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
1
1.0 - FIRST
Thank You
Choosing a power quality solution for your computer application can be a daunting task. That’s especially true when it comes to selecting a product that delivers uninterruptible power, since there are so many on the market to choose from. Everyone at ETA Systems thanks you for selecting an ETA power quality solution for your application. We understand that your decision was a careful one and that your purchase of an ETA product is an expression of confidence in our company. We promise to always work our hardest to make certain that your confidence in our products and our company is well deserved. Thank You!
The Security One product you have purchased is the most advanced solution available today. It does so much more than provide backup power for your application. In fact, it’s so advanced that it actually serves as a comprehensive management interface between your computer system and its supply of electrical power. That’s why we refer to the Security One as an Uninterruptible Power Manager or UPM.
We’ve prepared this document to help familiarize you with the functions and controls of the Security One UPM family. If, after reviewing this manual, you have any questions at all, please feel free to contact us by phone or email.
Registering your UPM Purchase
Please take a few moments to register your product purchase. Registration is easy and quick via the product registration page found on our website at www.etasys.com.
Technical Support
In North America, ETA Systems provides technical product support during our regular business hours of 8:00 a.m. to 5:00 p.m. Central Time. Between the hours of 5:00 p.m. and 8:00 a.m., our phone mail system will allow you to leave a message for our support department. The phone mail system also provides an emergency number to call in the event you should require immediate assistance. You may also communicate with our customer service/support department via fax or email. In North America, call (800) 321-6699. Our North American fax number is (330) 677-4471. You may also email either of our service and support locations via our website at www.etasys.com.
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
2
Warranty
ETA Systems warrants its uninterruptible power managers or UPM (known hereafter as the "product") to be free from defects in materials or workmanship for a period of five years from the date of shipment. Batteries are warranted for two years. The product will be repaired or (at ETA Systems' option) replaced at no charge during this warranty period. Product must be returned prepaid to the factory. See Page 18 for the full text of ETA Systems’ product warranty on the Security One UPM series.
Life Support
ETA Systems does not recommend the use of our UPM products on life support equipment where the failure of the UPM could endanger or compromise patient safety or diminish the effectiveness of such life support equipment. Reference page 109 of this manual.
2.0 – SAFETY ISSUES
IMPORTANT – SAVE THESE INSTRUCTIONS
THIS MANUAL CONTAINS IMPORTANT SAFETY INSTRUCTIONS. KEEP THIS MANUAL HANDY FOR REFERENCE.
CAUTION: A BATTERY CAN PRESENT A RISK OF ELECTRICAL SHOCK. SHORT-CIRCUIT CURRENTS CAN BE EXTREMELY HIGH AND CAN CREATE SEVERE BURNS AS WELL AS THE RISK OF FIRE OR EXPLOSION FROM VENTED GASES. ALWAYS OBSERVE PROPER PRECAUTIONS.
WHEN REPLACING BATTERIES, USE THE SAME QUANTITY, RATING AND TYPE OF BATTERIES USED BY ETA Systems. THE BATTERIES USED IN THIS UPM ARE SEALED LEAD-ACID AND ARE MAINTENANCE FREE. CONSULT THE CHART BELOW FOR QUANTITY AND RATING. PROPER DISPOSAL OF BATTERIES IS REQUIRED. REFER TO YOUR LOCAL CODES FOR DISPOSAL OF BATTERIES.
UPM Rating QUANTITY AND BATTERY
RATING 420 VA 2 X 4.5AH @ 12 VOLT 600 VA 2 X 4.5AH @ 12 VOLT 800 VA 2 X 7AH @ 12 VOLT 1100 VA 2 X 11AH @ 12 VOLT 1440 VA 4 X 7AH @ 12 VOLT
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
3
CAUTION !!
¾ THIS UPM CONTAINS VOLTAGES WHICH ARE POTENTIALLY HAZARDOUS. ALL REPAIRS
SHOULD BE PERFORMED BY QUALIFIED SERVICE PERSONNEL.
¾ THE UPM HAS ITS OWN INTERNAL ENERGY SOURCE (BATTERY). THE OUTPUT
RECEPTACLES OF THE UPM MAY BE LIVE EVEN WHEN THE UPM IS NOT CONNECTED TO AN AC SUPPLY.
Safe and continuous operation of the UPM depends partially on the care taken by users.
Please observe the following precautions.
PLEASE NOTE:
¾ Do not disassemble the UPM
¾ Do not attempt to power the UPM from any receptacle except a properly
grounded receptacle that matches the input plug provided with the UPM.
¾ Do not place the UPM near water or in environments of excessive humidity.
¾ Do not allow liquid or any foreign object to get inside the UPM.
¾ Do not block air vents on the side of the UPM.
¾ Do not plug appliances such as hair dryers, fans, heaters, etc. into the UPM.
¾ Do not place the UPM under direct sunshine or close to heat emitting sources
(excessively warm temperatures will shorten battery life).
¾ This UPM is intended for installation in a temperature controlled, indoor area
free of conductive contaminants.
¾ The AC power supply for the UPM should be conveniently near the UPM and easily accessible –
avoid extension cords or temporary power strips to power the UPM.
¾ The total leakage current of the UPM and consumer connected equipment should not exceed 3.5
mA.
¾ The battery should be disconnected from the UPM by unplugging at its quick connectors when
maintenance or service work inside the UPM is necessary.
¾ Do not dispose of batteries in a fire – batteries may explode.
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
4
¾ Do not open or mutilate batteries. Doing so may release electrolyte or other toxic substances,
which may be harmful to the skin, eyes, or the environment.
A battery can present a risk of electric shock and high short circuit current. The following precautions should be observed when working with batteries:
¾ Remove watches, rings, or any other metal jewelry or objects which may make contact with the
battery.
¾ Use tools with insulated handles.
¾ A certified detachable power supply cord is to be used with this equipment. For the 420, 600,
and 800 VA models, a type not lighter than SJT 18AWG should be used. For the 1100 and 1440 VA models, a type not lighter than SJT 16AWG should be used. (Also applies to Ground Guard, Hospital Grade, and Medical versions of this UPM product.)
3.0 – FCC ISSUES
Attention:
This equipment has been tested and found to comply with the limits for a Class A digital devices (Class B compliance optional), pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in both residential and commercial environments.
This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio and/or television reception, which can be determined by turning the UPM equipment on and off, the user is encouraged to try to correct the interference by one or more of the following measures:
¾ Reorient or relocate the receiving antenna.
¾ Increase the separation between the UPM and the receiver.
¾ Connect the UPM into an outlet on a circuit that is different from that to which the receiver is
connected.
¾ Consult the dealer or an experienced radio/TV technician for assistance.
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
5
4.0 – DOC ISSUES
Attention:
This equipment does not exceed Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications (Class B compliance optional). Operation in a residential or commercial area may cause unacceptable interference to radio and TV reception requiring the owner or operator to take whatever steps are necessary to correct the interference.
5.0 – OVERVIEW
General
The ETA Systems Security One Series of Uninterruptible Power Supplies are the most advanced, line­interactive, true sinewave UPM products available for your application. Each model is designed to provide total protection for your system from a complete range of power quality problems. Security One UPM solutions will protect your installation from normal mode voltage impulses, electrical noise, sags and surges, protracted brownouts, and complete blackouts. And because each Security One UPM contains an isolation transformer, it completely eliminates common mode (neutral to ground) voltages that are a constant threat to the reliable operation of microprocessor based systems. When AC power is present, Security One constantly filters and conditions the power supply. When AC power fails, Security One uses its internal, maintenance-free battery to supply reserve power to your computer system. Regardless of whether or not commercial power is present, Security One is constantly on the job, ensuring a fully conditioned, safely managed interface between your computer system and its electrical power supply. Figure 1 illustrates the basic operation of the Security One UPM.
Sinewave Output
The output voltage of all Security One UPM models is a true, low distortion sinewave – the kind that the utility company provides to the wall outlet and the kind that your equipment is designed to work with. This provides guaranteed compatibility even with the most sensitive electronic loads.
Voltage Manager
The voltage of the AC power source can often fluctuate from its nominal rating. These deviations in line voltage are tolerated quite well by most switch mode power supplies (the type used in your computer system). However, some UPS products may misinterpret these transient changes in line voltage as a power outage and erroneous battery operation may occur. This type of activity results in unnecessary strain on the battery and may eventually shorten its life. ETA Systems’s Security One UPM products feature Voltage Manager – a circuit that constantly monitors the AC power source. If minor changes in AC voltage occur,
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
6
Voltage Manager adjusts the input voltage to the UPM circuitry so that erroneous inverter operations are avoided. Ensuring that the UPM switches to its batteries only in the event of a true power outage results in longer battery life and a lower cost for both maintenance and ownership.
Start Manager
Start Manager is special circuitry that enables the internal batteries and allows you to start the Security One UPM from either the main AC supply or from its own internal battery. On occasion, AC power may not be available – such as when installing a system in a location where the electrical wiring has not been completed. Start Manager allows you to start the UPM and its connected system to perform final tests on both the UPM and the computer systems it’s powering.
Communications Manager
Many uninterruptible power systems provide only a basic software interface with the computer system they protect. Communications Manager combines the signaling capabilities of the Security One rear panel communication port with the management capabilities of ETA Systems’s communication software suite. Using your computer’s monitor, Communications Manager conveniently displays input and output voltage, output current, power line frequency, battery voltage, load percentage, and temperature. Communications Manager even initiates user defined automatic system shutdowns during extended power outages. Communications Manager allows a system operator to locally or remotely control the shutdown and startup of equipment connected to the Security One and provides this control either directly or through the operation of a customized schedule that can be developed to meet specific operating requirements.
Configuration Manager
Configuration Manager allows the user to control certain parameters of the Security One such as operating voltage. With Configuration Manager, for example, operating voltage of North American units can be set for 120 volts in the United States or 100 volts for Japanese installations. Some of Configuration Manager’s features are accessed through Communications Manager – such as those that allow adjustment to the voltage transfer points of the UPM inverter. With Configuration Manager you can even program Security One output receptacles to turn off themselves and their connected loads at pre-determined times following a power outage.
User Replaceable Battery
Eventually every UPM requires a new battery. ETA Systems expects the battery in your Security One UPM to last a minimum of two years – perhaps longer if power outages are short and infrequent. Security One makes battery replacement by the user easy and fast. And it’s not necessary to turn off the UPM or the connected system. Security One allows the battery to be “hot-swapped” while the system is running.
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
7
6.0 – OPERATION
Important Note: In order to operate the UPM, you must first plug the battery enable plug(s) into the battery enable socket(s) on the rear of the UPM.
On/Off Button
The On/Off button is a dual function control:
When the UPM is off and AC power is present to the UPM input, pressing the On/Off button for more
than 3 seconds will turn the UPM on. If battery enable plug(s) are installed, pressing the On/Off switch for 3 seconds or more will “cold-start” the UPM on its internal battery.
When the UPM is on, pressing the On/Off button for more than 3 seconds will turn off the UPM and
output power.
Test/Silence Button
The Test/Silence button is a dual function control:
Pressing the Test/Silence button when AC power is present and the UPM is operating causes the UPM
to enter a self test mode in which it tests both battery and inverter for a few seconds before returning to the AC supply. We recommend you close all open files before initiating self-test.
When AC power fails, the UPM warns you with an audible alarm. The Test/Silence button is used to
silence the alarm. When battery power begins to run low, the audible alarm will automatically return and beep at a faster rate.
Load Monitor
The Load Monitor is a 5-segment LED display that shows the current load percentage. The first four LEDs each indicate approximately 20% load. When illuminated, the final LED indicates that your connected equipment is consuming 110% of the UPM rated capacity.
Battery Charge Monitor
The Battery Charge Monitor is a 5-segment LED display that shows the charge capacity of the internal battery from zero to 100%. Each LED indicates approximately 20% of full charge.
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
8
Status Monitor
The status monitor is a row of six individual LEDs that each indicate the status of a part of your UPM system. The first three LED’s work with Security One’s Voltage Manager. All six LED’s are explained in the following table.
LED 1 Voltage Manager Boost Mode: When this LED is illuminated, Voltage Manager has detected that
a low voltage condition exists, and it is compensating by increasing voltage to the UPM input to the correct level.
LED 2 Voltage Manager Normal Mode: Voltage Manager has determined that input line voltage is
normal and within parameters. No adjustment is necessary.
LED 3 Voltage Manager Buck Mode: When this LED is illuminated, Voltage Manager has detected that
an overvoltage condition exists, and it is compensating by reducing voltage to the UPM input to the correct level.
LED 4 Battery Mode: When this LED is illuminated, either commercial AC power has been lost or the
UPM has been put into self-test using the Test/Silence button. In Battery Mode, the UPM is operating on its internal batteries. This LED will remain illuminated until the self-test is completed or until commercial AC power returns.
LED 5 Battery Weak: When this LED is illuminated, the battery requires either recharging or
replacement. If the LED remains illuminated after a 12-hour charge period, the internal battery should be replaced.
LED 6 Overload: When this LED is illuminated, the UPM is overloaded. Remove load from the UPM by
determining, which of the connected pieces of equipment is the least critical, and disconnect it from the UPM. Operating the UPM in an overloaded condition, may cause the UPM to protect itself by shutting down and removing power unexpectedly to all connected components.
Configuration Manager Receptacle Indicators
The four clustered LEDs in the center of the front panel indicate the output receptacle status as controlled by Configuration Manager. Configuration Manager addresses receptacle control differently for some of the models (See following explanation).
420 VA models: Configuration Manager treats receptacles 1and 2 as a group (Bank 1) and receptacles
3 and 4 as a group (Bank 2). For these models, LED 1 and 2 (Bank 1) will either be on together or off together. LEDs 3 and 4 (Bank 2) will also be on or off together. It is not possible to control receptacles 1 and 2 or receptacles 3 and 4 separately. It is only possible to separately control Bank 1 and Bank 2.
600 and 800 VA models
: The top two receptacles are Bank 1 and the bottom four receptacles are Bank
2. On these models, LED 1 and 2 (Bank 1) will either be on together or off together. LEDs 3 and 4 (Bank 2) will also be on or off together. It is not possible to control receptacles 1 and 2 or receptacles 3, 4, 5 and 6 separately. It is only possible to separately control Bank 1 and Bank 2.
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
9
1100 and 1440 VA models: Receptacles 1 and 2 are Bank 1 and LEDs 1 and 2 will either be on
together or off together. Receptacles 3 and 4 are Bank 2 (LED 3) and receptacles 5 and 6 are Bank 3 (LED 4). It is possible to control Bank 1, Bank 2, and Bank 3 independently from each other.
Site Wiring Fault Indicator – (North American Versions Only)
A red Site Wiring Fault LED is located on the rear panel of the UPM. This LED is designed to illuminate if the UPM is connected to an improperly wired AC receptacle. This indicator is designed to indicate a missing safety ground wire or a reversal in phase and neutral wiring. This indicator should be visually checked during installation and, if illuminated, you should contact a qualified electrician immediately.
Note: Do not operate the UPM if the Site Wiring Fault LED is illuminated. When lit, the LED is indicating a wiring condition, which may represent a hazard of fire or electrocution. In addition, improper wiring may create reliability problems for both the UPM and the connected system. Never use a 3 blade to 2-blade adapter (often called a “cheater”) with the UPM. These devices remove the safety ground connection to the UPM and will cause the Site Wiring Fault LED to illuminate.
Communication Manager Port
Communication Manager provides a connection point on the rear panel of the UPM (both DB9 and USB ports). Connecting to this port and installing Communication Manager’s software package (optional), will allow you control over important UPM functions and access to operating information from the UPM. Using Communications Manager’s software, you can view such parameters as AC input and output voltage, powerline frequency, and battery voltage. The following table illustrates the available parameters.
Input Voltage Indicates the actual input voltage to the UPM
when AC power is present Output Voltage Indicates the actual output voltage of the UPM AC Frequency Indicates the actual output frequency of the UPM Battery Voltage Indicates the actual DC voltage of the internal
battery buss Change Battery Indicates the battery is incapable of holding a
charge and requires replacement Percent Load Indicates the percentage of VA capacity being
used by connected load Temperature Indicates the actual internal temperature of the
UPM
Communications Manager also can support simple software programs that rely on basic “contact closure” signaling from the UPM. An example would be the built in UPS Service provided in Windows® NT. The functions of basic software control usually include the following:
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
10
Broadcast warnings of power failures/timed shutdowns Automatic closure of files prior to battery exhaustion Power down of the UPM and connected equipment
To support these functions without the Communications Manager software suite, you will need to either buy or build your own special cable. The following table describes the pin assignment of the DB9 connector on the rear of the UPM. Contact your computer supplier to determine the connection configuration and connector style necessary to attach the cable to the computer.
Pin # Description
1
Reserved
2
UPM simulates a relay closing between Pins 2 and 4 when input power fails
3
Reserved
4
Common Ground
5
UPM simulates a relay closing when battery has less than 2 minutes runtime remaining*
6
UPM sends a RS232 high (12V) for 1 second after input power fails (normally low). Also functions as receive data.
7
Common Ground
8
Reserved
9
RS232 transmit data
* Load Dependent
Notes:
1. Pins 1, 2, and 5 are open collector outputs, which must be pulled up to a common referenced supply. Switch rating: +40V, 0.15A non-inductive.
2. Pins 4 and 7 should only be connected to ground.
Important Note: You may, of course, connect your computer to the UPM without using Communications Manager. When power is lost, the UPM will beep and you will have to manually shut down the computer and UPM.
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
11
Configuration Manager
Configuration Manager provides control over important operation parameters of the UPM. Configuration Manager controls these parameters through the settings on the DIP (dual inline pin) switch pack on the rear panel and also through certain selections accessed by Communications Manager software.
Operating Voltage: The DIP switches can be used to configure the UPM operating voltage. For North American models, the UPM can be configured to operate at 100, 110, 115, or 120 volts. International models can be configured for 220, 230, or 240 volts. The following table illustrates the required switch settings for each selection.
Voltage Required SW#1 SW #2 SW #3 SW #4
100V/208V On Off Off Off 110V/220V Off On Off Off
120/230V Off Off On Off 127/240V Off Off Off On
If Communications Manager software is installed on the host PC, Configuration Manager can use it to adjust both Low Voltage Transfer Point and High Voltage Transfer Point. The following table provides the allowable set points for adjusting transfer voltage (key in all three numbers shown).
Low Voltage Transfer Points (key in all three numbers)
Model Set Pt.
1
Set Pt. 2 Set Pt. 3 Set Pt.
4 North American 089 091 093 096 International 176 181 186 192
High Voltage Transfer Points (key in all three numbers)
Model Set Pt.
1
Set Pt. 2 Set Pt. 3 Set Pt.
4 North American 141 145 148 151 International 282 290 296 302
Low Battery Warning Time: Low battery warning time can be configured for either two or five minutes before UPM shutdown depending on the requirements of the application. It should be noted that these times
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
12
are at full load with a healthy battery. Partial loads and/or aged batteries will affect the accuracy of this timer setting.
Receptacle On/Off Control: Set the turn-off times of the receptacle groups and individual receptacles on the rear panel.
Start Manager
When AC power is not available, such as in a new installation where wiring may be incomplete, you can still start the UPM to test its operation and the operation of your system using Start Manager. With the UPM off, follow these simple steps:
1. Disconnect the input AC power cable from the rear panel of the UPM.
2. Ensure that the battery enable plug(s) are inserted into the rear panel battery enable socket(s).
3. Press and hold the On/Off switch on the front panel until the UPM beeps.
4. The UPM is now running on battery. When you have finished, press the On/Off switch again. Plug the input AC power cable into the rear panel of the UPM.
7.0 – UNPACKING, INSPECTION, TESTING AND TROUBLESHOOTING
Please Note: Before installation, please read and understand the following instructions. Carefully examine
the packing carton for damage. Notify the carrier immediately if damage is observed. Be sure to save the carton should you ever need to ship the UPM for repair or maintenance.
Placement
This UPM is intended for indoor use only. Although your UPM is very rugged, its internal components are not sealed from the environment. The UPM must be installed in a protected environment away from heat producing appliances such as furnaces, radiators, and heaters. Protect the UPM from exposure to dripping or standing water and high humidity or condensing air conditions. The location should provide adequate airflow around the UPM. Provide a minimum 1” clearance on all sides for proper ventilation.
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
13
Applying Power to the UPM
For North American versions, connect the power cord to a verified grounded 3 wire receptacle. For international versions, unplug the cord from your computer and plug into the inlet of the UPM. Then use the cord supplied with the UPM to connect the UPM to your computer.
For North American versions, verify that the Site Wiring Fault LED is off. Once properly connected and initially checked, turn on the UPM by pressing and holding the front panel On/Off switch for 3 seconds.
Operational Tests
Observe the front panel of the UPM. The following table shows how the front panel LED should appear upon start-up.
Indicator Load
Monitor
LEDs
Battery Monitor
LED’s
Receptacle
Monitor
LEDs
Voltage
Manager
Boost
Voltage
Manager
Normal
Voltage
Manager
Buck
Battery
Mode
LED
Battery
Weak
LED
Overload
LED
Status Off On All On Off On Off Off Off Off
Note: Depending on the charge state of the battery, it is possible that some of the Battery Monitor
LEDs may be off.
With the connected equipment powered off, perform an initial test of the UPM backup function by pressing the Test/Silence button on the front panel. During this test, the Battery Mode LED on the front panel should briefly illuminate. It is also possible to test the backup function by unplugging the UPM input power cord. If you choose to test the UPM in this manner, you will note that the UPM will beep every four seconds while the power cord is unplugged. The Battery Mode LED will also illuminate constantly.
Once you have performed an initial test of the UPM backup function, turn on the connected computer equipment. Verify that the Overload LED is off. If the Overload LED is illuminated, remove the least critical devices from the UPM one by one until the overload light is extinguished. With the connected loads powered up, perform the backup test once again by pressing the Test/Silence button or unplugging the UPM. When this final test is completed, the UPM will be ready to use.
Please Note:
If you leave your UPM on continuously, it is a good idea to perform a test at least once a month.
If you are utilizing Communications Manager software, you can configure the system to automatically self-test periodically.
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
14
The UPM is shipped with a charged battery, but some discharge naturally occurs during storage
and shipment. You may use the UPM immediately, but you should realize that backup time may be less than the stated rating until the UPM battery has had at least six hours to charge.
ETA Systems recommends that you do not plug laser printers into the UPM.
Laser printers are known to draw large amounts of current when the fuser/heater assembly is energized. Laser printers can easily overload the UPM or create a low voltage condition that can interfere with the operation of the Voltage Manager circuit.
Storage
The UPM may be stored for extended periods in an environment that does not subject the UPM to extremes of temperature or humidity. When storing for extended periods, the battery should be charged every 3 months. If the storage location is characterized by above normal temperature, the battery should be recharged every two months. The UPM does not need to be turned on for charging to occur – it only needs to be plugged in.
Note: This product is not designed for continuous use on batteries.
Troubleshooting
The troubleshooting information provided in this section should help you discover the cause of most commonly encountered difficulties. Before following the troubleshooting steps provided, be certain that you have verified the following items:
The UPM should be plugged into a properly working outlet. The line voltage to the UPM is within specified boundaries. The circuit breaker on the rear panel of the UPM has been reset. The battery enable plug (s) is installed.
Problem Possible Cause Action you should take UPM does not power up and has no audible alarm
1. On/Off button is not pressed long enough
2. No incoming line voltage or voltage too high or too low
3. UPM input power cord is not plugged in
4. Rear panel circuit breaker is tripped
1. Press and hold the On/Off switch for 3 seconds min.
2. Check wall socket and test for proper line voltage.
3. Plug in input power cord
4. Reduce load and reset circuit breaker.
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
15
UPM Overload LED is illuminated and continuous audible alarm sounds
UPM is overloaded Reduce load by removing the least
critical load items from the UPM
output. Low/Replace Battery LED is illuminated
Battery voltage is too low or battery is dead.
Recharge battery for at least six
hours and reset the UPM. If LED is
still illuminated, replace the battery. Site Wiring Fault LED is illuminated
Site wiring problem Contact a qualified electrician to
verify wiring at this site. Backup time is less than expected
Battery is not fully charged or battery is dead.
Recharge battery for at least six
hours and retest backup time. UPM is normal, but the computer will not turn on.
Computer input power cord is loose or not connected.
Connect computer input power cord.
Communication Manager not working
1. Wrong interface cable
2. Computer’s serial port has not been properly configured.
3. Computer’s I/O card is bad
1. Purchase correct cable
2. Check to see that the port
is enabled in the CMOS
settings. Also check for
IRQ conflicts. Make sure
settings match those found
in Communications
Manager.
3. Replace I/O card
Important Information
The batteries inside this UPM are a special type called “sealed lead-acid”. These batteries use a non-liquid electrolyte, which makes it possible to use them in any physical orientation. The batteries are designed to last from 2 to 5 years. Their actual life span will depend on several factors including how often power outages occur, how long power outages last, and the temperature of the environment in which the UPM operates. Frequent, long duration power outages will shorten battery life more than infrequent, short duration outages. Consistent high temperatures in the area where the UPM is used will also shorten battery life.
The UPM is equipped with a Low/Replace Battery LED on the front panel. If the LED illuminates, you should make sure that the battery has at least six hours to charge without a power interruption. Inadequate (much shorter than usual) backup time, premature low battery alarm sounds, and persistent Low/Replace Battery LED illumination are all good signs that the battery inside your UPM requires replacement. The batteries inside your UPM are designed to be easily replaced by a user who possesses basic mechanical/electrical knowledge and simple tools. Please familiarize yourself with the following precautions before proceeding with battery replacement.
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
16
WARNING !!
Servicing of batteries should always be performed or supervised by someone who has read and understood the following precautions and who understands the hazards associated with storage batteries. This procedure should not be performed by someone who is unauthorized or who is incapable of following these precautions.
OBSERVE THE FOLLOWING CAUTIONS
" Only the battery assembly in this unit is user serviceable. The battery compartment is
accessed by removing the front panel as described in the following instructions. No other user serviceable parts are contained in this UPM. Do not remove any cover other than the front battery access panels.
" A battery (even a depleted one) can deliver very high currents when short-circuited.
There is a danger of electrical shock. Remove all watches, rings, bracelets or other metal objects. Use only tools with insulated handles.
" Do not dispose of batteries in a fire. There is a danger of explosion. Do not dispose of
batteries in an environmentally unfriendly manner. Batteries may be returned to ETA Systems for proper disposal.
" Do not open or mutilate the batteries. This may release electrolyte that is toxic to the
environment and harmful to the skin and eyes.
" Replacement batteries may be ordered from ETA Systems by phone or via our website
at www.ETA Systems.com
. If purchasing batteries from another source, be sure to use
the type and quantity of batteries described in the table in Section 10.
8.0 – USER REPLACEABLE BATTERY
Please note: Changing the batteries in this UPM is designed to be a safe and simple
procedure. Batteries may be replaced while the UPM is on and providing power to the connected load. You should remember, however, that if a power outage occurs after the old batteries are disconnected and before the new batteries are installed, power will be lost to your connected system and components.
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
17
Please note: If you have read and understood the cautions preceding this section, you may proceed with the following steps. Consult Figure 6 to assist you in the following battery replacement procedure.
Battery Replacement
1. Remove the two small screws from the bottom of the front panel that secure the front panel to the frame
of the UPM.
2. Carefully slide the front panel off the UPM taking care not to damage or tear the ribbon cable that
connects the front panel “dashboard” display to the UPM.
3. Remove the screw(s) that secures the battery assembly retaining bracket, remove it from the unit, and
set it to one side.
4. Slide the battery pack from the UPM by pulling on the tab provided.
5. Disconnect the battery from the UPM by pulling apart the wire leads at the connector(s) provided.
6. Connect the new battery pack to the UPM by reconnecting the connector(s) making sure to observe
proper polarity (i.e. black to black and red to red).
7. Push the new battery pack into place.
8. Replace the battery retaining bracket removed in step 3 and replace the screw(s) that secures it in
place.
9. Slide the front panel (removed in step 2) back on the front of the UPM taking care not to pinch or
damage the ribbon cable.
10. Replace the front cover screws and tighten.
9.0 – UPM WARRANTY
ETA Systems warrants its uninterruptible power managers or UPM (known hereafter as the "product") to be free from defects in materials or workmanship for a period of five years from the date of shipment. ETA Systems warrants the batteries used in the product to be free from defects in materials or workmanship for a period of two years from the date of shipment. The product will be repaired or (at ETA Systems's option) replaced at no charge during this warranty period. Product must be returned prepaid to the factory.
ETA Systems makes no warranties, expressed or implied, of merchantability, fitness for a particular purpose, performance, condition, capacity or otherwise. ETA Systems is not liable for incidental or consequential damages, monetary loss, loss of sales, or loss of business resulting from the failure or malfunction of the product.
Warranty is void on any product that is misused,
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
18
misapplied, abused, altered or repaired by any unauthorized personnel or where evidence of tampering exists. The foregoing constitutes the sole and exclusive remedy of the purchaser and is in lieu of all other warranties. No greater degree of liability is imposed on ETA Systems.
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
19
1.0 – PRIMERO
Gracias
La escogencia de una buena solución en materia de energía para su aplicación en su computadora puede ser una tarea intimidante. Ésto es especialmente cierto cuando se trata de seleccionar un producto de suministro de energía ininterrumpible, puesto que hay tantos para escoger en el mercado. Todos nosotros en ETA Systems le agradecemos a usted la escogencia de una buena solución en materia de energía — ETA Systems— para su aplicación. Nosotros comprendemos que su decisión fue cuidadosa y que su compra de un producto ETA Systems es una expresión de confianza en nuestra compañía. Le prometemos esforzarnos siempre al máximo para sostener la veracidad de que su confianza en nuestros productos y en nuestra compañía es bien merecida. ¡Gracias!
El producto de Security One que usted ha comprado es hoy por hoy la solución más avanzada disponible. Hace mucho más que darle capacidad de energía suplementaria a su aplicación. De hecho, es tan avanzado que en realidad sirve como una interfaz de administración comprensiva entre su sistema de computadora y su suministro de energía eléctrica. Es por ello que nos referimos al Security One como un Administrador Ininterrumpible de Energía (Uninterruptible Power Manager o UPM)
.
Hemos preparado este documento para ayudarlo a familiarizarse con las funciones y los controles de la familia Security One UPM. Si después de revisar este manual usted aún tiene cualquier pregunta, por favor siéntase en libertad de comunicarse con nosotros por teléfono o email.
El Registro de su Compra UPM
Tome por favor algunos momentos para colocar su compra del producto. El registro es fácil y rápido vía la página del registro del producto encontrada en nuestro Web site en www.eta sys.com.
Apoyo Técnico
En Estados Unidos, ETA Systems brinda apoyo técnico a sus productos en las horas hábiles, de 8:00 a.m. a 5:00 p.m. Tiempo del Centro. Entre las 5:00 p.m. y las 8:00 a.m., nuestro sistema telefónico le permitirá a usted dejar un mensaje para nuestro departamento de apoyo. Asimismo, el sistema de correo de voz también suministra un número de emergencia para llamar en caso de que usted requiera ayuda inmediata. Usted también puede comunicarse con nuestro servicio al cliente/ departamento de apoyo por fax o email. En Estados Unidos, llame al (800) 321-6699. Nuestro número de fax en Estados Unidos es el (330) 677-
4471. Puede obtener acceso a servicio y apoyo en nuestro sitio de la Red www.etasys.com.
Desde la
Página Principal, presione en SERVICE y vaya al enlace apropiado.
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
20
Garantía
ETA Systems garantiza que sus administradores de energía ininterrumpible o UPM (en lo sucesivo denominados como el “producto”) están libres de defectos en sus materiales o en su manufactura durante un periodo de cinco años a partir de la fecha de su despacho. Las baterías están garantizadas por dos años. El producto será reparado o (a opción de ETA Systems) reemplazado durante este periodo de garantía, sin cargo alguno. El producto debe ser devuelto a la fábrica con porte pagado. Vea en la Página 38 el texto completo de la garantía de producto ETA Systems en la serie Security One UPM.
Soporte de Vida
ETA Systems no recomienda la utilización de nuestros productos UPM en equipos de soporte de vida en los que la falla del UPM pudiera de alguna manera poner en peligro o comprometer la seguridad del paciente o disminuir la efectividad de dichos equipos de soporte de vida. Referencia de paginación 109.
2.0 – SEGURIDAD
¡¡IMPORTANTE !! – CONSERVE ESTAS INSTRUCCIONES
ESTE MANUAL CONTIENE IMPORTANTE INSTRUCCIONES DE SEGURIDAD. CONSERVE A SU ALCANCE ESTE MANUAL PARA SU CONSULTA.
PRECAUCIÓN: UNA BATERÍA PUEDE PRESENTAR UN RIESGO DE CHOQUE ELÉCTRICO. LAS CORRIENTES DE CORTOCIRCUITO PUEDEN SER EXTREMADAMENTE ALTAS Y PUEDEN PRODUCIR QUEMADURAS SEVERAS ASÍ COMO EL RIESGO DE FUEGO O EXPLOSIÓN DE ESCAPES DE GASES. OBSERVE SIEMPRE LAS PRECAUCIONES APROPIADAS. CUANDO CAMBIE LAS BATERÍAS, USE LA MISMA CANTIDAD, LA MISMA CLASIFICACIÓN Y EL MISMO TIPO DE BATERÍAS EMPLEADAS POR ETA Systems. LAS BATERÍAS USADAS EN ESTE UPM ESTÁN SELLADAS A PRUEBA DE ÁCIDOS DE PLOMO Y NO REQUIEREN MANTENIMIENTO. PARA INFORMACIÓN ACERCA DE CANTIDAD Y CLASIFICACIÓN, CONSULTE LA TABLA QUE SE OFRECE A CONTINUACIÓN. SE REQUIERE UNA ADECUADA
DISPOSICIÓN FINAL DE LAS BATERÍAS.
PARA LA DISPOSICIÓN FINAL DE LAS BATERÍAS, CONSULTE SUS CÓDIGOS LOCALES.
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
21
UPM Rating QUANTITY AND BATTERY
RATING 420 VA 2 X 4.5AH @ 12 VOLT 600 VA 2 X 4.5AH @ 12 VOLT 800 VA 2 X 7AH @ 12 VOLT 1100 VA 2 X 11AH @ 12 VOLT 1440 VA 4 X 7AH @ 12 VOLT
¡¡PRECAUCIÓN!!
¾ ESTE UPM CONTIENE VOLTAJES QUE SON POTENCIALMENTE PELIGROSOS. TODA
REPARACIÓN DEBE SER EFECTUADA POR PERSONAL CALIFICADO DE SERVICIO.
¾ ESTE UPM POSEE SU PROPIA FUENTE INTERNA DE ENERGÍA (BATERÍA). LOS TOMAS DE
SALIDA DEL UPM PUEDEN ESTAR VIVOS AUN SI EL UPM NO ESTÁ CONECTADO A UN SUMINISTRO DE CA.
La operación segura y continua del UPM depende en parte del cuidado que le den sus usuarios. Por
favor, observe las siguientes precauciones.
POR FAVOR, TENGA EN CUENTA:
¾ No desarme el UPM
¾ No intente ponerle energía al UPM desde ningún toma excepto uno que
tenga la adecuada conexión a tierra y que se ajuste al enchufe suministrado con el UPM.
¾ No coloque el UPM cerca de agua ni en ambientes con excesiva humedad.
¾ No permita que entren líquidos o ningún objeto extraño al interior del UPM.
¾ No bloquee las salidas laterales de aire del UPM.
¾ No enchufe en el UPM aparatos como secadores de pelo, ventiladores,
calentadores, etc.
¾ No coloque el UPM directamente bajo la luz del sol o cerca de fuentes emisoras de calor (las temperaturas excesivamente altas pueden reducir la vida útil de las baterías).
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
22
¾ Este UPM está hecho para su instalación en una temperatura controlada, en áreas interiores
libres de contaminantes conductores.
¾ La fuente de energía de CA para el UPM debe estar convenientemente cerca del UPM y debe ser
de fácil acceso. Evite los cables de extensión o las cuerdas de energía temporal para suministrarle energía al UPM.
¾ La pérdida total de energía del UPM y del equipo consumidor conectado no debe exceder los 3.5
mA.
¾ Cuando sea necesario efectuar trabajos de mantenimiento o de servicio en el interior del UPM,
la batería debe ser desconectada del UPM desenchufando sus conectores rápidos.
¾ No descarte las baterías tirándolas al fuego, porque pueden explotar.
¾ No destape ni mutile las baterías. Al hacerlo puede dejar escapar electrolitos u otras sustancias
tóxicas que pueden ser nocivas para la piel, los ojos o el medio ambiente.
Una batería puede presentar un riesgo de choque eléctrico y de un cortocircuito de alta corriente. Deben observarse las siguientes precauciones cuando se esté trabajando con baterías:
¾ Quítese pulseras, anillos o cualquier otra joyería metálica u otros objetos que puedan hacer
contacto con la batería.
¾ Use herramientas con mango aislante.
¾ Con este equipo debe usarse un cable separable certificado de suministro de energía. Para los
modelos 420, 600 y 800 VA debe usarse un tipo no más liviano que el SJT 18AWG. Para los modelos 1100 y 1440 VA debe emplearse un tipo no más liviano que el SJT 16AWG. (También es aplicable para las versiones Ground Guard, Hospital Grade and Medical de este producto UPM).
3.0 – FCC INFORMACIÓN
Atención:
Este equipo ha sido puesto a prueba y se ha llegado a la conclusión de que cumple con los límites fijados para los dispositivos digitales de las Clase A de acuerdo con la Parte 15 de las normas de la FCC. (Conformidad de la clase B opcional). Estos límites están diseñados para dar una protección razonable contra interferencia nociva en ambientes tanto residenciales como comerciales. Este equipo genera, utiliza y puede radiar energía de radiofrecuencia, y si no se ha instalado y no se usa de acuerdo con las instrucciones, puede provocar interferencia dañina a las radiocomunicaciones. No obstante, no existe garantía de que esa interferencia no ocurra en el caso de una instalación en particular.
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
23
Si este equipo causa interferencia dañina a la recepción radial o de televisión, lo cual puede determinarse prendiendo y apagando el equipo UPM, se le recomienda al usuario tratar de corregir la interferencia mediante la aplicación de una o más de las siguientes medidas:
¾ Reoriente o relocalice la antena receptora. ¾ Aumente la separación entre el UPM y el receptor. ¾ Conecte el UPM en un toma cuyo circuito sea diferente a aquel al cual está conectado el
receptor.
¾ Para obtener ayuda, consulte al vendedor o a un técnico de radio/TV.
4.0 – DOC INFORMACIÓN
Atención:
Este equipo no excede los límites de la Clase A para emisiones de ruido de radio de aparatos digitales establecidos en la Reglamentación de Interferencia de Radio del Departamento Canadiense de Comunicaciones. (Conformidad de la clase B opcional). La operación en un área residencial o comercial puede provocar una interferencia inaceptable a la recepción de radio y TV, que requiera al propietario o al operador adoptar cualesquiera pasos necesarios para corregir tal interferencia.
5.0 – VISIÓN GENERAL
General
La Serie ETA Systems Security One de Suministros de Energía Ininterrumpibles son los productos UPM más avanzados, interactivos en línea, de verdadera onda sinusoidal, disponibles para su aplicación. Cada modelo está diseñado para proveer una protección total a su sistema frente a un completo rango de problemas de energía de calidad. Las soluciones Security One UPM protegerán su instalación de impulsos de voltaje de modo normal, ruido eléctrico, caídas y sobrecargas, reducciones de tensión de línea prolongadas y apagones totales. Y dado que cada Security One UPM contiene un transformador de aislamiento, elimina completamente los voltajes de modo común (de neutro a tierra) que constituyen una constante amenaza para la operación confiable de los sistemas a base de microprocesador. Cuando hay energía de CA, Security One filtra y acondiciona constantemente el suministro de energía. Cuando falla la energía de CA, Security One utiliza su batería interna que no requiere mantenimiento, para suministrarle reserva de energía a su sistema de computadora. Sin importar si hay o no energía comercial, Security One trabaja constantemente, asegurando así una interfaz plenamente acondicionada y de manejo seguro entre su sistema de computadora y su suministro de energía eléctrica. La Figura 1 ilustra la operación básica del Security One UPM.
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
24
Salida de Onda Sinusoidal
El voltaje de salida de todos los modelos Security One UPM es una verdadera onda sinusoidal de baja distorsión, de la misma clase que la compañía de servicios públicos suministra para las tomas de pared y del tipo con el cual está diseñado el trabajo de su equipo. Ésto brinda garantía de compatibilidad aun para las cargas más sensibles.
Administración del Voltaje (Voltage Manager™)
El voltaje de la fuente de energía de CA con frecuencia puede fluctuar a partir de su rango nominal. Estas desviaciones en el voltaje de la línea son bastante bien toleradas por la mayoría de los suministros de interruptores de energía (de la clase utilizada en su sistema de computadora). No obstante, algunos productos UPS pueden interpretar equivocadamente estos cambios momentáneos del voltaje de la línea como una falla de la energía, y puede presentarse entonces una operación errónea de la batería. Esta clase de actividad tiene como resultado un esfuerzo innecesario de la batería y puede llegar a acortar su vida útil. Los productos Security One UPM de ETA Systems ofrecen el Administrador de Voltaje, un circuito que monitorea constantemente la fuente de energía de CA. Si se presentan cambios menores en el voltaje de CA, el Administrador de Voltaje ajusta el voltaje de entrada a la circuitería del UPM de modo que se evitan las operaciones de inversión erróneas. Al cerciorarse de que el UPM cambia a sus baterías solamente en caso de que se presente un verdadero apagón se logra prolongar la vida útil de la batería, y se consigue un costo más bajo tanto en el mantenimiento como en la propiedad misma.
Administrador de Arranque (Start Manager™)
El Administrador de Arranque es una circuitería especial que le permite las baterías internas y a usted arrancar el Security One UPM tanto del suministro principal de CA como de su propia batería interna. Ocasionalmente, la energía de CA puede no estar disponible, como cuando se está instalando un sistema en un sitio en el que el cableado eléctrico aún no se ha completado. El Administrador de Arranque le permite arrancar el UPM y el sistema conectado a él para efectuar las pruebas finales de que el UPM y los sistemas de la computadora están recibiendo energía.
Administrador de Comunicaciones (Communications Manager™)
Muchos sistemas ininterrumpibles de energía suministran únicamente un software básico de interfaz con el sistema de computadora que protegen. El Administrador de Comunicaciones combina las capacidades de señalización del panel posterior del puerto de comunicación del Security One con las capacidades de administración de la comunicación del conjunto de software de ETA Systems. En el monitor de su computadora, el Administrador de Comunicaciones muestra de manera conveniente el voltaje de entrada y de salida, la corriente de salida, la frecuencia de la energía de la línea, el voltaje de la batería, el porcentaje de carga y la temperatura. El Administrador de Comunicaciones incluso inicia el sistema automático definido de apagado durante apagones prolongados. El Administrador de Comunicaciones le permite al
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
25
operador de un sistema controlar localmente o en remoto el apagado y el encendido de un equipo conectado al Security One y provee este control directamente o mediante la operación de un programa especialmente diseñado para cumplir requisitos específicos de operación.
El Administrador de Configuración (Configuration Manager™)
El Administrador de Configuración le permite al usuario el control de ciertos parámetros del Security One, como el voltaje de operación. Con el Administrador de Configuración, por ejemplo, el voltaje de operación de las unidades de Estados Unidos pueden fijarse para 120 viltios en los Estados Unidos o 100 voltios para instalaciones japonesas. Se puede obtener acceso a algunas partes del Administrador de Configuración por medio del Administrador de Comunicacionescomo en el caso de las que permiten ajustar los puntos de transferencia de voltaje del inversor del UPM. Con el Administrador de Configuración usted incluso puede programar el Security One para que las tomas se apaguen por sí mismas y apaguen las cargas conectadas a ellas en tiempos predeterminados después de un apagón.
Batería que el Usuario Puede Cambiar
Se llega el momento en que el UPM necesita una batería nueva. ETA Systems espera que la batería de su Security One UPM dure un mínimo de dos años, y quizás aún más si no hay apagones con frecuencia. El Security One hace que el reemplazo de la batería por parte del usuario sea una tarea fácil y rápida. Y no es necesario apagar el UPM o el sistema conectado a él. El Security One permite a la batería el “intercambio en caliente” mientras el sistema está operando.
6.0 – OPERACIÓN
Nota Importante
: Para funcionar el UPM, usted debe primero tapar la batería permite el plug(s) en la
batería permite el socket(s) en la parte posterior del UPM.
Botón de Encender/Apagar
El botón de Encender/Apagar es un control de función doble.
Cuando el UPM está apagado y hay energía de CA en la entrada del UPM, al presionar el botón de
Encender/Apagar por más de tres segundos se encenderá el UPM. Si la batería permite el plug(s) está instalada, apretando el botón de Encender/Apagar por tres o más segundos, el UPM “arrancará en frío” con su batería interna.
Estando el UPM encendido, al apretar por más de 3 segundos el botón de Encender/Apagar se
apagarán el UPM y la salida de energía.
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
26
Botón de Prueba/Silencio
El botón de Prueba/Silencio es un control de función doble:
Al apretar el botón de Prueba/Silencio cuando hay energía de CA y el UPM está operando, se hace
que el UPM entre en un modo de autoprueba en el cual prueba la batería y el inversor por unos pocos segundos antes de regresar al suministro de CA. Le recomendamos que cierre todos los archivos abiertos antes de iniciar la autoprueba.
Cuando hay una falla de la energía, el UPM le advierte a usted con una alarma audible. Se emplea el
botón de Prueba/Silencio para silenciar la alarma. Cuando empiece a funcionar despacio la energía de la batería, la alarma audible retornará automáticamente y dará un tono breve (bip) a una intensidad mayor.
Monitor de Carga
El Monitor de Carga es una pantalla LED (light-emiting diode) de 5 segmentos que muestra el porcentaje de carga existente en el momento. Cada uno de los primeros cuatro LEDs indica aproximadamente el 20% de carga. Cuando está iluminado, el LED final indica que su equipo conectado está consumiendo un 110% de la capacidad considerada del UPM.
Monitor de Carga de la Batería
El Monitor de Carga de la Batería es una pantalla LED de 5 segmentos que muestra la capacidad de carga de la batería interna desde cero hasta 100%. Cada LED indica aproximadamente un 20% de la carga total.
Monitor de Estado
El Monitor de Estado es una hilera de de seis LEDs individuales que indican el estado de una parte de su sistema UPM. Los primeros tres LEDs funcionan con el Administrador de Voltaje del Security One. Los seis LEDs se explican en el siguiente cuadro.
LED 1 Modo de Refuerzo del Administrador de Voltaje: Cuando este LED está iluminado, el Administrador de
Voltaje ha detectado que existe una condición de bajo voltaje, y que se está compensando mediante el aumento de voltaje a la entrada del UPM hasta el nivel correcto.
LED 2 Modo Normal del Administrador de Voltaje: El Administrador de Voltaje ha determinado que el voltaje de la
línea de entrada es normal y que está dentro de los parámetros. No se necesita ajuste.
LED 3 Modo de Compensación del Administrador de Voltaje: Cuando este LED está iluminado, el Administrador de
Voltaje ha detectado que hay una condición de sobrecarga y que se está compensando mediante la reducción del voltaje a la entrada del UPM hasta el nivel correcto.
LED 4 Modo de Batería: Cuando este LED está iluminado, puede ser que se haya perdido la energía comercial de
CA o que el UPM haya sido colocado en autoprueba utilizando el botón de Prueba/Silencio. En el Modo de Batería, el UPM está operando con sus batería internas. Este LED seguirá iluminado hasta que la autoprueba se haya completado o hasta que retorne la energía comercial de CA.
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
27
LED 5 Batería Débil: Cuando este LED esté iluminado, la batería necesita ser recargada o reemplazada. Si el LED
sigue iluminado después de un periodo de 12 horas de carga, la batería interna debe ser reemplazada.
LED 6 Sobrecarga: Cuando este LED está iluminado, el UPM está sobrecargado. Retire carga
del UPM determinando cuál de las partes conectadas del equipo es la menos crítica, y desconectándola del UPM. Si se opera el UPM en condición de sobrecarga, se puede provocar que el UPM se proteja a sí mismo apagándose y quitándoles inesperadamente la energía a todos los componentes conectados a él.
Administrador de Configuración Indicadores de Tomas
Los cuatro LEDs agrupados en el centro del panel frontal indican la condición del toma como controlada por el Administrador de Configuración. El Administrador de Configuración dirige el control del toma de manera diferente para algunos de los modelos (Vea la siguiente explicación).
Modelos 420 VA: El Administrador de Configuración trata los tomas 1 y 2 como un grupo (Banco 1) y
los tomas 3 y 4 como otro grupo (Banco 2
). Para estos modelos, los LEDs 1 y 2 (Banco 1) estarán prendidos los dos o apagados los dos. Los LEDs 3 y 4 (Banco 2) también estarán prendidos o apagados conjuntamente. No es posible controlar los tomas 1 y 2 o los tomas 3 y 4 por separado. Sólo es posible controlar separadamente el Banco 1 y el Banco 2.
Modelos 600 y 800 VA:
Los dos tomas superiores son el Banco 1 y los cuatro tomas de la parte inferior son el Banco 2. En estos modelos, los LEDs 1 y 2 (Banco 1) se encenderán o se apagarán conjuntamente. Los LEDs 3 y 4 (Banco 2) también se prenderán o se apagarán los dos. No es posible controlar los tomas 1 y 2 o los tomas 3, 4, 5 y 6 separadamente. Sólo es posible controlar separadamente el Banco 1 y el Banco 2.
MODELOS 1100 y 1440 VA: Los Tomas 1 y 2 son el Banco 1 y los LEDs 1 y 2 se encenderán o se
apagarán conjuntamente. Los tomas 3 y 4 son el Banco 2 (LED 3) y los tomas 5 y 6 son el Banco 3 (LED 4). Es posible controlar el Banco 1, el Banco 2 y el Banco 3 independientemente uno del otro.
Indicador de Ubicación de Falla de Cableado (Únicamente en Versiones Norteamericanas)
Un LED rojo de Ubicación de Falla de Cableado está localizado en el panel posterior del UPM. Este LED está diseñado para iluminarse si el UPM está conectado a un toma de CA impropiamente cableado. Este indicador está diseñado para mostrar la falta de un cable de seguridad a tierra o un cableado de inversión en fase y neutro. Este indicador debe ser revisado visualmente durante la instalación y, si se ilumina, de inmediato, usted debe comunicarse con un electricista calificado.
Nota: No opere el UPM si el LED de Ubicación de Falla de Cableado está iluminado. Al estar encendido, el LED está indicando un problema de cableado, que puede implicar un riesgo de fuego o de electrocución. Además, un cableado inadecuado puede crear problemas de seguridad tanto para el UPM como para el
ETA Systems® - SECURITY ONE UNINTERRUPTIBLE POWER MANAGER
28
sistema conectado a él. Nunca emplee en el UPM un adaptador de cuchilla 3 a 2 (llamado a menudo “cheater” o “prolongador”). Estos aparatos suprimen la conexión de seguridad a tierra del UPM y pueden hacer que se ilumine el LED de Ubicación de Falla de Cableado.
El Administrador de Comunicaciones (Communications Manager) Puerto ( Puerto DB9)
El Administrador de Comunicaciones provee un puerto de conexión en el panel posterior del UPM (DB9 y USB). La conexión a este puerto y la instalación del paquete de software del Administrador de Comunicaciones (opcional), le permitirán a usted el control de importantes funciones del UPM y el acceso a la operación de información del UPM. Con la utilización del software del Administrador de Comunicaciones, usted puede ver parámetros como el voltaje de entrada y de salida de la CA, la frecuencia de energía de la línea y el voltaje de la batería. El cuadro siguiente ilustra los parámetros disponibles.
Voltaje de Entrada Indica el voltaje de entradaal UPM en el momento,
cuando hay energía de CA Voltaje de Salida Indica el voltaje de salida del UPM en el momento Frecuencia de la CA Indica la frecuencia de salida del UPM en el momento Voltaje de la Batería Indica el voltaje de CD del bus de la batería interna Cambio de la Batería Indica que la batería está en incapacidad de mantener
una carga y necesita su reemplazo Porcentaje de Carga Indica el porcentaje de la capacidad de VA que está
siendo usado por carga conectada Temperatura Indica la temperatura interna del UPM en el momento
El Administrador de Comunicaciones también puede dar apoyo a programas sencillos de software que se sostienen en señalización básica de “cierre de contacto” del UPM. Un ejemplo podría ser el Servicio de instalación interna en el UPM suministrado en Windows® NT. Las funciones de control del software básico usualmente incluyen las siguientes:
Emisión de advertencias de fallas de la energía/apagado con tiempo programado Cierre automático de archivos antes del agotamiento de la batería Suspensión de energía del UPM y del equipo conectado a él
Para sostener estas funciones sin el conjunto de software del Administrador de Comunicaciones, usted necesitará comprar o fabricar su propio cable especial.. El siguiente cuadro describe la asignación de los pernos del conector DB9
que está en la parte posterior del UPM. Comuníquese con su proveedor de computadoras a fin de determinar la configuración de la conexión y el estilo de conector necesarios para adosar el cable a la computadora.
Loading...
+ 81 hidden pages