The data in this document may not be altered or amended without special notification from ETAS GmbH. ETAS GmbH undertakes no further obligation in relation to this document. The software described in it can only be used if the
customer is in possession of a general license agreement or single license. Using
and copying is only allowed in concurrence with the specifications stipulated in
the contract.
Under no circumstances may any part of this document be copied, reproduced,
transmitted, stored in a retrieval system or translated into another language
without the express written permission of ETAS GmbH.
The introductory chapter informs you about the basic safety information, product return and recycling, the use of this manual,
information.
the scope of delivery and other
1.1Basic Safety Instructions
1.1.1Labeling of Safety Instructions
The safety instructions contained in this manual are identified by the general
danger symbol shown below:
The safety instructions shown below are used for this purpose. They provide
notes about e
carefully.
xtremely important information. Please read this information very
Identifies an immediate danger with high risk, which could result in
death or severe bodily injury if it is not avoided.
Identifies a possible danger with medium risk, which could result in
death or (severe) bodily injury if it is not avoided.
Identifies a danger with low risk that could result in slight or moderate bodily injuries or property damage if it is not avoided.
1.1.2General safety information
Please observe the product safety advice ("ETAS Safety Advice CBN" and the
subsequent safety instructions to avoid any impact on your health or damages to
the device.
Carefully read the documentation that belongs to the product (ETAS Safety
Advice CBN and this User’s Guide) prior to the startup.
ETAS GmbH does not assume any liability for damages resulting from improper
handling, unintended use or non-observance of the safety precautions.
1.1.3Requirements for users and duties for operators
The Isolating Measurement Probe product may be commissioned and used only
by qualified electricians for high-voltage systems (BGI/GUV-I 8686 of the DGUV,
minimum Level 2).
The product may be assembled, operated and maintained only if you have the
necessary qualification and experience for this product. Improper use or use by a
user without sufficient qualification can lead to damages or injuries to one's
health or damages to property.
General safety at work
The existing regulations for safety at work and accident prevention must be followed.
1.1.4Correct Use
This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.
Requirements for Operation
This is a class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to
take adequate measures.
Check before each use of the product in high-voltage systems its
function by measuring a known extra-low voltage.
The following requirements are put in place for safe operation:
• The Isolating Measurement Probe product meets the requirements of protection class IP65. Observe the notes for the ambient conditions (see chapter 3.1.4 on page 20).
• Use the product only according to the specifications ion the corresponding
user's guide. For any other use, the product safety is not ensured.
• This product must not be used for measuring of mains supply circuits.
• Observe the regulations concerning electrical safety and the laws and regulations concerning occupational safety applicable at the application site!
• Observe the rules for working on equipment with dangerous voltages!
• Carefully attach the high-voltage measuring cables.
• Keep the high-voltage measuring lines short to minimize the risks of injuries from pinching, contracting, scoring or shearing.
• Do not use the product in a wet or humid environment.
• Do not use the product in a potentially explosive atmosphere.
• Keep the surfaces of the product clean and dry.
Requirements for the technical State of the Product
The product is designed in accordance with state-of-the-art technology and recognized safety rules. The product may be operated only in a technically flawless
condition and according to the intended purpose and with regard to safety and
dangers as stated in the respective product documentation. If the product is not
used according to its intended purpose, the protection of the product may be
impaired.
Risk of electric shock with damaged housing of a measuring
channel or damaged insulation of a high-voltage cable!
Electric shock upon touching energized components of the Isolating
Measurement Probe leads to injuries, heart failure or death.
A damaged Isolating Measurement Probe must be decommissioned
immediately!
Ensure that the damaged Isolating Measurement Probe is not
longer being used!
A repair of the Isolating Measurement Probe is not possible, attempts
to repair are not permissible!
Maintenance and cleaning
The product is maintenance-free. For cleaning, use a clean and dry cloth.
The high-voltage side of the housings of the measuring channels of the
CBN101.1/ CBN103.1/ CBN105.1/ CBN107.1 Isolating Measurement Probe is
identified in orange. The following symbols are used for identifying the product:
SymbolDescription
Before using the product, carefully read the user’s guide!
840 VMaximum input voltage 840 V
Measuring input, minus
Measuring input, plus
Housing protected with double insulation (acc. to EN 61010-1)
Identification for CE, see chapter 1.3 on page 8
Identification for RoHS, see chapter 1.5.1 on page 9
Identification for China RoHS, see chapter 1.5.2 on page 9
Observe the information in chapter "Technical data" on page 19.
1.3CE marking
ETAS confirms that the product meets the product-specific applicable European
Directives with the CE marking affixed to the product or its packaging. The CE
Declaration of Conformity for the product is available upon request.
1.4Product return and recycling
The European Union (EU) issued the Waste Electrical and Electronic Equipment
(WEEE) Directive to ensure the setup of systems for collecting, handling and processing electronic waste in all countries of the EU.
This ensures that the equipment is recycled in a resource-saving manner that
does not represent any risk for the health and safety of humans and the environment.
Fig. 1-1WEEE symbol
The WEEE symbol (see Fig. 1-1 on page 9) on the product or its packaging identifies that the product may not be disposed of together with garbage.
The user is obligated to collect used equip
the WEEE return system for recycling.
The WEEE directive relates to all ETAS equip
batteries.
Additional information about the recycling pr
obtained from the ETAS sales and service branch offices (see chapter 5
on page 29).
ment separately and provide them to
ment, but not to external cables or
ogram of ETAS GmbH can be
1.5RoHS conformity
1.5.1European Union
The EU Directive 2002/95/EU limits the use of certain dangerous materials for
electrical and electronic devices (RoHS conformity).
ETAS confirms that the product corresponds to this directive which is applicable
in the
European Union.
1.5.2China
ETAS confirms that the product meets the product-specific applicable guidelines
of the China RoHS (Management Methods for Controlling Pollution Caused by
Electronic Information Products Regulation) applicable in China with the China
RoHS marking affixed to the product or its packaging.
1.6About this manual
This manual describes the startup and technical data of the CBN101.1/
CBN103.1/ CBN105.1/ CBN107.1 Isolating Measurement Probe product.
1.6.1Organization
The manual consists of four chapters and one index.
• Chapter 1: "General"
The "General" chapter (this chapter) in
information, product return and recycling, the use of this manual, the
scope of delivery and other information.
The "Hardware description" chapter pr
CBN101.1/ CBN103.1/ CBN105.1/ CBN107.1 Isolating Measurement
Probe and information about the power supply, the measuring channels
and their housing, the connections and cabling, the cable identification
and the serial number.
• Chapter 3: "Technical Data"
The "Technical data" chapter describes the
have been met, the ambient conditions, the application area, the system
requirements for operating the CBN101.1/ CBN103.1/ CBN105.1/
CBN107.1 Isolating Measurement Probe, the electrical data, the mechanical data, and the mapping of the measuring channels.
• Chapter 4: "Ordering Information"
The "Ordering Information" chapter includes the ordering information for
the a
vailable cables and the accessories.
The concluding chapter "ETAS Contacts" gives you information about the international ETAS sales and service branch offices.
1.6.2Working with the manual
ovides an overview of the
standards and guidelines that
Typographical conventions
The following typographical conventions are used:
BoldLabels of the device
ItalicsParticularly important text passages
Important notes for the user are represented as follows:
Important note for users.
1.7Scope of supplies
Before the initial startup of your CBN101.1/ CBN103.1/ CBN105.1/ CBN107.1
Isolating Measurement Probe, please verify that the device has been delivered
with all the required parts (see the chapter "Ordering Information" on page 27).
This chapter provides an overview of the Isolating Measurement Probe
CBN101.1/ CBN103.1/ CBN105.1/ CBN107.1 and information about housing,
serial number and connections.
2.1Overview
2.1.1Combined use with measuring modules
The Isolating Measurement Probe CBN101.1/ CBN103.1/ CBN105.1/ CBN107.1
is a signal conditioning cable with an active voltage measuring channel integrated in the cable for the combined use w
ers.
The combination of the measurement modules with the
Probe expands their application range by the potential-free measurement of
voltages up to 10 V, e.g. in the high-voltage electrical system of
tric vehicle systems. The electrical isola
age electrical system and the measurement module occurs close to the
uring point in the measuring channel of the isolating measurement probe.
meas
The Isolating Measurement Probe CBN101.1/ CBN103.1/ CBN105.1/ CBN107.1
pr
ovides an efficient solution for measuring voltages during the development,
application and validation of ECUs of the electric drive.
2.1.2Product variants
ith A/D modules from external provid-
Isolating Measurement
hybrid and elec-
tion between the voltage in the high-volt-
The Isolating Measurement Probe CBN101.1/ CBN103.1/ CBN105.1/ CBN107.1
was developed for these applications and is available in four different assembled
variants:
Isolating Measurement Probe
CBN101.1Open Wire
CBN103.1Lemo FGA.0B.306with A/D module
CBN105.1Lemo FGG.1B.306with A/D module
CBN107.1Lemo FGG.1B.310with A/D module
The complete technical data of the Isolating Measurement Probe CBN101.1/
CBN103.1/ CBN105.1/ CBN107.1 is located in the chapter
on page 19.