Service Information .......................................................................................... 8
Page 4
General
Thank you for choosing an Etac product.
To avoid accidents and injury when moving and handling
the products, read the manual carefully.
The person described as "the user" in this user manual
is the person who is lying or sitting on the product. The
assistant or assistants are the people who manoeuvre the
product.
This symbol appears alongside the text in
the manual. It draws the reader's attention
to points at which there may be a risk to the
health and safety of the user or assistant.
The products comply with the standards applicable for
Class 1 products in the European Council Directive MDD
93/42/EEC on medical devices.
Lot no/Batch no:
xxxxxxxxxx
Production year Running number
Symbols
At Etac we strive to improve our products all the time and
therefore we reserve the right to make changes to products without prior warning. All measurements given on
illustrations and similar material are for guidance only and
Etac cannot be held liable for errors and defects.
The information given in this manual, including recommendations, combinations and sizing, does not apply to
special orders and modifications. If the customer makes
adjustments, repairs or combinations not predetermined
by Etac, the Etac CE certification and Etac warranty will
be voided. If in doubt, please contact Etac.
Warranty: Two-year warranty on material and manufacturing defects, provided that the product is used correctly.
For further information on the Etac transfer range, see
www.etac.com.
The product can be scrapped in accordance with national
regulations.
Washing
Handwash
Wipe off
Tumbledry
Keep out of the sun
Iron
Do not dryclean
Do not bleach
Risk of sliding down
Intended use
Autoturn is specially developed for use with car seats to
make it easy to enter and exit a vehicle. The two nylon
sides facing each other reduce friction during turning. The
down part of the Autoturn pillow has a non-slip surface,
Intended enviroment
Never leave on the floor
Warning
Read the User Manual
Batch no./Lot no.
User mass limit = maximum
rated load
The product can be
scrapped in accordance
with national regulations
Manufacturer
Class 1 - European Council
Directive MDD 93/42/EEC
on medical devices
to ensure that the device rests firmly on the car seat.
Autoturn is fastened to the seat back.
Autoturn features a functional handle which a assistant
can use to pull the user into place on the car seat.
Acute care, Long-term care, Home care
4
Page 5
Practical handling
Positioning
Position the Autoturn centrally on the car seat.
Fit the straps, fasten and tighten securely at seat back.
Fit the functional locking system (next to the functional
handle) to the safety belt. When the user turns in the
seat, the belt will automatically glide slightly forward.
The safety belt can be secured on the opposite side using
the functional locking system (Illustration 4).
Use
The user seats him/herself on the centre of the Autoturn.
The user then raises either both legs simultaneously or one
leg at a time inside the vehicle, thus turning the body inside
the car (Autoturn is also perfect for turning the user inside
the vehicle) (Illustrations 1,2 and 3). This avoids unnecessary
strain on the body. The assistant can pull on the functional
handle to help the user glide into place.
To exit the car, the user swings the legs out of the vehicle,
preferably in stages, before raising him/herself to the standing position.
Page 6
Special features
Notice
Always check the product before use and after washing.
Never use a defective product. If the product shows signs
of wear-and-tear, it must be scrapped.
Read these instructions carefully.
It is important that assistants receive instruction in manual
handling. Etac offers advice and training for assistants. For
further information, contact Etac.
Always use the correct manual handling techniques.
Encourage the client to assist where possible.
To ensure that the client feels safe and that every manual
handling is smooth, always plan the manual handling in
advance.
There is a risk that the user may slide off. Never
leave the user alone on the edge of the bed.
Never leave the product on the floor.
Always make a risk assessment, and secure that the
assistive product can be used at the individual user
and in combination with other devices that it is safe
for the user and caregivers.
Always fit the strap, fasten and tighten securely at
the seat back.
The product should be checked regularly, preferably each
time it is used, and especially after wash.
Check that there is no damage to seams or fabric.
Never try to repair a product yourself.
Never use a defective product.
Washing instructions:
Do not use fabric softener.
Recommended to wash the product before use.
6
Page 7
Articles
Article no.DescriptionSize (mm)
IM99999Autoturn Ø450
Page 8
Service Information
Thank you for choosing an Etac product. If the customer makes adjustments, repairs or combinations not predetermined by Etac, the
Etac CE certification and Etac warranty will be voided.
Warranty: Two-year warranty on material and manufacturing defects, provided that the product is used correctly. Before taking a
product in service always make a risk assesment according to national and/or local legislation.
First inspection:
• Is the packaging intact?
• Read the label on the packaging and check the article no. and product description
• Check that Short Instruction is enclosed – updated User Manual/Instruction for use can be downloaded from www.etac.com or contact your
Etac Customer Service or the local distributor.
• Check the label on the product - does it include article no., product description, lot/batch no., cleaning instructions and supplier name?
Periodic Inspection:
• Make sure that your Manual transfer system always is in a perfect condition.
• After wash – always check materials, stitching, handles, buckles.
• If the product shows signs of wear and tear, it must be removed from service immediately.
• Lot no/Batch no:
xxxxxxxxxx
Production year Running number
Visual inspection/Check the product:
Ensure that the materials, seams, stitching,
handles, buckles are intact/faultless.
Mechanical load or stress/Test handles:
Draw hard in the handles in opposite directions
and control the material, seams and stitching.
Test buckles:
Lock the buckle and draw in opposite directions,
control the buckle and the stitching.
Stability test:
Try to bend the product verify that it feels firm,
stable and solid.
Test low/high friction:
Place the product on a firm surface or a bed,
place your hands on the material and test the
friction by pushing your hands down into the
product.
Low friction – slides effortlessly
High friction – no sliding/moving
Check always:
Manual transfer aids with handles, straps and buckles: Manual transfer aids for sitting and lying transfer:
Manual transfer aids with high or low friction:
The product can be
scrapped in accordance
with national regulations
Read the
User Manual
If in doubt, please contact Etac Customer Service or local distributor for more information and guidance.
For more information about training and the use of these products, contact the Etac transfer experts – www.etac.com.
Class 1 - European Council
Directive MDD 93/42/EEC
on medical devices
R82 UK Ltd.
Unit D4A, Coombswood Business Park, East Coombswood Way,
Halesowen,West Midlands B62 8BH, UK
Tel 0121 561 2222
Fax 0121 559 5437
R82uk@r82.com www.r82.co.uk
Snug Seat Inc.
12801 E. Independence Blvd., P.O. Box 1739, Matthews, NC 28106, US
Tel 1 800 336 7684
Fax 704 882 0751
information@snugseat.com www.snugseat.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.