1 General information 4
1.1 Introduction 4
1.2 Elements of the set 4
1.3 Precautions 5
1.4 Procedure with the used equipment 6
2 Connecting to the system 6
2.1 Electrical wiring 6
2.2 Location 6
2.3 Connection to the controller 7
2.3.1 IGNEO Wall (Platinum Bio)................................................................8
2.3.1 IGNEO Wall (Platinum Bio)................................................................8
2.3.2 IGNEO Slim.....................................................................................9
2.3.2 IGNEO Slim.....................................................................................9
2.3.3 IGNEO Compact.............................................................................10
2.3.3 IGNEO Compact.............................................................................10
2.3.4 Settings in the controller of boiler.....................................................11
2.3.4 Settings in the controller of boiler.....................................................11
3 Utilization 11
3.1 Signal LEDs 11
3.2 Adjustment of temperature 11
4 Non-standard configuration 12
4.1 Switches 12
4.1.1 Addressing....................................................................................12
4.1.1 Addressing....................................................................................12
4.1.2 Change of transmission mode..........................................................13
4.1.2 Change of transmission mode..........................................................13
4.1.3 Selection of controller.....................................................................14
4.1.3 Selection of controller.....................................................................14
4.2 Calibration 14
5 Specification 15
estyma electronics
www.estyma.pl
page 3
PL20130612
1 General information
1 General information
Thank you for choosing our product. We congratulate you on making a good decision.
We welcome any remarks on the operation of device.
Team
ESTYMA electronics
1.1 Introduction
First of all, the objective of device is to measure the room temperature. The controller is also
used for a smooth change of temperature in the room. You can increase or lower the temperature by
3,5oC specified in the settings of controller. You can adjust the temperature in the room in a fast and
convenient way. The set consists of transmitter and receiver, which provide wireless communication. Due
to addressing application, a parallel operation of up to 8 transmitter-receiver sets in the same residential
building is possible. The transmitter is powered by 2 AAA batteries. The device operates correctly in the
range from 0 C to 50 oC.
The controller operates only with the most modern controllers of Estyma company, starting from,
Platinum Bio series. It is operated not only by the main controller, but also by CAN I/O expansion units.
Due to this fact, it is possible to adjust the temperature in each of the rooms freely depending on the
system configuration.
The controller is not fit for the operation with the controllers of earlier generation and devices
made by other manufacturers.
1.2 Elements of the set
1. Wireless controller (transmitter) of room temperature
2. Wireless receiver of room temperature
3. Set of screws and installation pins
page 4
PL20130612
Content
1.3 Precautions
Before you start to operate the device, read the whole attached user`s guide carefully.
Keep the user`s guide and refer to it in case you operate the device in future.
Observe all the rules and warnings included in the user`s guide.
Make sure the device is not damaged in any way. In case of doubt, do not operate the device and
contact the supplier.
In case of doubt concerning a safe operation of device, contact the supplier.
Special attention should be paid to warning signs, housing or packaging of device.
Operate the device according to its intended use.
The device is not a toy,children should be prohibited from playing with it.
On no account can children play with any part of the packaging of this device.
Children should be prevented from accessing small parts, for example, clamping screws, pins.
These elements can be found on the equipment of device supplied and in case of swallowing they
can lead to the choking of child.
No mechanical or electrical moddifications can be made in the device. Such modifications can
cause the wrong operation of device, incompatible with standards or they can influence the
operation of device in a negative way.
No objects should be put into the device through gaps (for example ventilation gaps). This can
cause short circuit, electrical shock, fire or damage to the device.
Make sure that no water, moisture, dust and dirt gets into the device. This can cause short circuit,
electrical shock, fire or damage the device.
Make sure the device is ventilated properly, do not cover ventilation holes and provide a free
flow of air around it.
The device should be installed inside the rooms.
Make sure that the device is not exposed to impacts and vibrations.
Connecting the device, make sure that electric parameters of power supply network are within
the operation range of device.
Any connections must be compatible with the installation electrical wiring diagram and with
national, or local regulations relating to electrical connections.
There is no part in this device that can be replaced by the user himself. All service operations
except cleaning and setting up the function, should be carried out by the authorized service staff.
Before starting any maintenance operations, you must absolutely disconnect the device from
power supply.
No benzine, solvents or other chemical agents, which can damage the housing of device, can be
used for cleaning the device. A soft cloth is recommended for this purpose.
estyma electronics