This manual and the firmware described in it are copyrighted by Electronic Systems Technology (EST), with all rights reserved. Under the
copyright laws, this manual or the firmware internal to the ESTeem unit may not be copied, in whole or part, without the written consent of
EST. Under the law, copying includes translating into another language.
EST cannot guarantee that you will receive notice of a revision to the firmware described in the manual, even if you have returned a
registration/warranty card received with the product. You should periodically check with your authorized EST dealer or call factory direct.
EST and the EST logo are registered trademarks of Electronic Systems Technology, Inc. Simultaneously published in the United States
and Canada. All rights reserved.
WARRANTY INFORMATION
Electronic Systems Technology, Inc., (hereinafter EST) expressly warrants its products as free of manufacturing defects for a period of one
year from the date of sale to first user/customer.
THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED AND THERE IS EXPRESSLY EXCLUDED ALL WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. NO OTHER WARRANTY GIVEN BY ANY EMPLOYEE, AGENT,
DISTRIBUTOR OR OTHER PERSON WITH RESPECT TO THE PRODUCT SHALL BE BINDING ON EST.
LIMITATION OF LIABILITY:
EST's liability shall be limited to refunding of purchase price, repair or replacement of product.
IN NO EVENT SHALL EST HAVE LIABILITY FOR CONSEQUENTIAL, INCIDENTAL, SPECIAL OR EXEMPLARY DAMAGES
CAUSED DIRECTLY OR INDIRECTLY BY THE PRODUCT, INCLUDING BUT NOT LIMITED TO ANY INTERRUPTION OF SERVICES,
LOSS OF BUSINESS OR ANTICIPATORY PROFITS. IN NO EVENT SHALL EST BE LIABLE FOR ANY DAMAGES WHATSOEVER IN
EXCESS OF THE PURCHASE PRICE OF THE PRODUCT.
In the event that a unit or part requires replacement or factory servicing, the following conditions apply:
a)Customer must obtain from EST an authorized RMA (Return Materials Authorization) number (call 509-735-9092 Customer Support)
before shipment of product or parts to EST for any reason;
b)If the whole unit is shipped, it must be in its original carton and shipping components, or a carton and shipping components supplied
by EST, or if parts only are shipped, they must be packaged and cushioned so as to prevent damage in transit and shipped freight
prepaid;
PRODUCT WILL BE CONSIDERED OUT OF WARRANTY IF:
a)If the product is damaged due to improper or abnormal use, abuse, mishandling, accident or improper maintenance or failure to
follow operating instruction;
b)If the product is defective as a result of sand, dirt, or water damage;
c)If any factory-sealed enclosure has been opened or shows evidence of an attempt to be opened;
d)If defects or damage are caused by the use of unauthorized parts or unauthorized service;
e)If the product has had its serial numbers altered or removed.
Warranty repair form must be accompanied by proof of user's purchase of unit. Product must be shipped to the manufacturer at the
following address:
Electronic Systems Technology
415 North Quay Street
Kennewick, Washington USA 99336
ADDITIONAL SERVICE:
If EST releases an improvement update to firmware internal to the ESTeem unit during the 90 day period after the unit was purchased by the
first user/customer, EST will update the applicable unit with the revised version at no charge other than for UPS handling and shipping to and
from your location to the EST factory. Return of any such item must be accompanied with proof of purchase.
TABLE OF CONTENTS
CHAPTER 1 – STARTING OUT
Before You Start1-1
ESTeem Utility1-1
Installing ESTeem Utility Software1-1
Running the Program1-2
Starting Out1-2
Basic ESTeem Programming1-4
Help Functions1-4
Saving a Program1-5
Restoring Factory Defaults1-5
Digi-Repeater3-1
Global Broadcast3-2
Auto Transmit3-2
Auto Connect3-3
Multi-Connect3-4
Remote Programming3-5
Security3-5
Hardware Ring Line3-6
Packet Monitor3-6
Using the Infrared Communications Port3-7
Updating Flash Memory3-8
DTE vs DCE5-1
Flow Control5-2
Memory Buffers5-3
Data Terminal Ready5-3
RS-422/485 Configuration5-4
RS-232/422/485 Configuration Tables5-4
RS-232/422/485 Port Pin-out Table5-4
RS-232/422/485 COMRATE Table5-5
Revised: 13 Sep 20051-1 EST P/N AA104
TABLE OF CONTENTS
CHAPTER 6 – ANTENNAS
Coaxial Cable6-1
Weather Proofing Coaxial Connectors6-2
Grounding6-2
Lightning Arrestors6-2
Reference Material6-2
Model 192C/F Outdoor Antenna Fixed Base Hardware Diagram6-3
Model 192CHP Outdoor Antenna Fixed Base Hardware Diagram6-4
Model 192M Outdoor Antenna Fixed Base Hardware Diagram6-5
Model 192MHP Outdoor Antenna Fixed Base Hardware Diagram6-6
Model 192C/F Indoor/Mobile Antenna Hardware Diagram6-7
Model 192CHP Mobile Antenna Hardware Diagram6-8
Model 192M Indoor/Mobile Antenna Hardware Diagram6-9
Model 192MHP Mobile Antenna Hardware Diagram6-10
Model 192C/CHP/F/M/MHP SWR Measurement Diagram6-11
CHAPTER 7 – THEORY OF OPERATION
Introduction7-1
ESTeem How It Works7-1
Spectrum Utilization7-2
Packet Protocols7-2
Flow Control7-2
Data Privacy7-2
Effective Baud Rate7-3
APPENDIX A – FCC INFORMATION (USA only)
Information to UsersAPX A-1
Other InformationAPX A-2
Federal Communications Commission Field OfficesAPX A-3
Congratulations on your purchase of the ESTeem Wireless
Modem! This section of the manual will describe the basic
functioning and programming of the ESTeem to get your
wireless network up as soon as possible. It is
recommended that any first time user of the ESTeem and
those that are unfamiliar with its operation complete all
steps in this section before proceeding.
Take a few minutes to inventory your equipment before
you proceed. Report any missing or damaged items to
Customer Support as soon as possible. We at Electronic
Systems Technology, Inc. (EST) are constantly trying to
improve our products and support system so if you have
any comments or suggestions on improvement of this
manual, please contact us at (509) 735-9092.
The completion of this section requires loading the ESTeem Utility
program on your computer. The following section will describe the
installation and use of this valuable utility program.
ESTEEM UTILITY
ESTeem Model 192 Utility
Software Windows Version
Magnetic Mount Antenna
(Consult Appendix B for
12 VDC Power Supply
(EST P/N AA174)
antenna type)
Computer Running
Windows 95/98/NT
TNC Male
Connector
RS-232C Interface Cable
(EST P/N AA061)
ESTeem Model 192
Front View
2 Pin Molex
Connector
Figure 1: Installation Diagram
The ESTeem Utility is designed to assist the ESTeem user in
programming and troubleshooting. The Utility covers basic
operation, programming, PLC applications, and diagnostics of the
ESTeem. The ESTeem Utility Program is designed to operate with
Windows ®.
Installing ESTeem Utility Software From ESTeem
Resourse Disk (AA109)
The ESTeem Resource Disk is stand-alone copy of the ESTeem
Web site (Figure 2). Navigation of the Resource Disk is as simple
as using your web browser. All technical documentation, User’s
Manuals and the ESTeem Utility Program is available on the disk.
1. Place the ESTeem Utility CD in your CD-ROM drive. The CD
will auto load the ESTeem main page (Figure 1).
2. If the page does not auto load, open your web browser and set
your address line to D:\1_default.html (Where D: is the drive
letter for your CD-ROM drive).
3. From navigation menu on the left side of the page, select
ESTeem Utilities (Figure 1).
4. Select the Windows version of the ESTeem Utility and click
Download Windows Utility for Model 192 Series. When asked
to Open or Save the file, press Open to view the contents of the
Zip file.
Figure 2: ESTeem Utility Setup Menu
Figure 3: ESTeem Utility Main Menu
Revised: 15 Oct 031-1 EST P/N AA104
5. Double Click on the Setup.exe file to start the Utility Installation
or extract the files to a directory for later installation.
Running the Program
1. Select the ESTeem Utility Icon on Start>Programs menu. Figure 3
shows an example of the Main Utility Menu.
STARTING OUT
This section covers the basics setup and testing for the ESTeem
wireless modem. If this is your first experience with the ESTeem
wireless modems or you are unclear on how to set the frequency,
squelch, or test communication, the ESTeem Starting Out section will
guide you through the basics of wireless communication.
CHAPTER 1
STARTING OUT
1. Select ESTeem Starting Out from the main menu. A window like
the one in Figure 4 will be displayed. If this is your first time
using the ESTeem wireless modems, select ESTeem Setup Guide for a
complete description of all ESTeem functions. Proceed to step 2.
2. Step 1 – Installing External Power window will be displayed (Figure 5).
Select either Find ESTeem or the model number of ESTeem you are
programming. The power requirements for that product will be
displayed. The ESTeem model AA174 power supply can be used with
all ESTeem products. If you are using the ESTeem in a solar power
application, press Calculate Solar Consumption button for the
Amp/Hours required. Press Go to Step 2 to continue.
3. Step 2 – ESTeem Familiarization window will be displayed (Figure 6).
This step will explain the connections to ESTeem Model 192 front
panel. See Figure 1 for a setup diagram.
4. Press the Front Panel Description button and a window containing the
ESTeem Model 192 front panel will appear (Figure 7). Press any one of
the buttons for a complete description of the item’s function. For
example, press the Power LED button and the description of the
power LED and its use will be displayed. Press Go To Step 3
button to proceed.
5. Step 3 – Serial Connection window will be displayed (Figure 8).
This step will help configure the computer and the ESTeem to
communicate with each other.
6. Press Display Cable Diagrams button and all serial pins to the
ESTeem Model 192 will be displayed. Press OK to continue.
Note:A standard 9-Pin serial port on a computer to ESTeem
interface cable is the ESTeem AA061 (Figure 1).
7. Press Change Port Settings. This window will configure the
communications port on your computer to operate with the
ESTeem modem. Select the operating parameters you wish or
set to the default of 19,200,N,8,1. Click OK to continue.
Figure 4: Starting Out Main Menu
Figure 5: Step 1 - Installing External Power
Figure 6: Step 2 – ESTeem Familiarization
Revised: 15 Oct 031-2 EST P/N AA104
CHAPTER 1
STARTING OUT
8. Press Set Serial Switches button. This window will
configure the ESTeem’s RS-232/422/485 to operate at
the setting selected in step 7 to match the computer
port setting. Follow the on-line guide to configure the
data rate.
9. Press Test ESTeem button. If the ESTeem serial
interface cable and communication port are operating
correctly the ESTeem Welcome Message will be
displayed. This will confirm communication between
the computer and the ESTeem. If you do not receive a
welcome message, follow the on-screen
troubleshooting guide that will be displayed. Press
Go to Step 4 button to proceed.
10. Step 4 – ESTeem Setup Parameters window will be
displayed (Figure 9). This step will complete the setup
for your ESTeem Model 192.
11. Press Set Frequency button. Select the operating frequency for
your ESTeem Model 192 and press Set Frequency to continue. Set
all ESTeems to the same frequency for operation within this
section.
12. Press Set Squelch/Antenna button. This section will give you
instructions on antenna placement and installation. Press the Set
Squelch button and follow the on-line guide to configure the
ESTeem squelch. Press OK to continue.
13. Press Set Address button. You must give each ESTeem a unique
address in the system. Type in the address number and press OK
to continue.7
14. Press Complete Setup. You have just configured all operating
parameters within the ESTeem. If this is your first ESTeem you
have programmed for testing, press the Express Setup button on
the Staring Out Menu (Figure 4) to program subsequent ESTeem
Modems. The Express Setup will allow you to quickly configure
the remaining ESTeem modems without additional instruction.
If you have at least two ESTeems programmed and wish to
test communication, proceed to step 17.
15. Press Test Communication button. This section will allow
you to test the radio frequency (RF) communications between
two or more ESTeems. Two types of tests are listed in this
window (Figure 10). If you have a computer attached to both
ESTeems proceed to step 18 and if you only have one
computer to test both ESTeems proceed to step 19.
16. The first test will be used if you have a computer attached to
both ESTeems. Select the first of two items and press
ENTER. Follow the instructions on the screen to establish a
communication link between modems.
17. This second test will allow you to use the remote ESTeem as
a digi-repeater for your local modem. This procedure is
explained in the window and can test communication with
only one computer.
18. You now have completed the basic programming and setup of
your ESTeem modems. You have tested their operation with
Transmit LED
Receive LED
Antenna Connector
(TNC-R)
T/E LED
•Link Connect/Disconnect
•Auto Connect Enable
•Serial Port Framing Error
Reset Switch
12 VDC Input
Power Connector
(2 Pin Molex)
RS-232/422/485
Setup Switches
Power LED
IR Port
RS-232, 422 and 485
Input/Output Connector
(25 Pin DB Connector)
Figure 7: ESTeem Front Panel
Figure 8: Step 3 – Serial Connection
Figure 9: Step 4 – ESTeem Setup Parameters
Revised: 15 Oct 031-3 EST P/N AA104
each other and are now ready to proceed in programming
them for your application. Press Exit to Main Menu and
continue with the programming of the ESTeem for your
application.
BASIC ESTEEM PROGRAMMING
Most of the ESTeem commands outlined in this section have been
automatically input to the modem by the ESTeem Utility program.
A few of the commands used most often in troubleshooting and
programming are covered here. These commands can be
programmed to the modem directly by the Terminal Emulation
section of the utility or by any other terminal software package.
CHAPTER 1
STARTING OUT
HELP Functions
The ESTeem has over eighty software commands to aid the user in their application. The HELP command allow the user to list
the various software commands and their respective values.
From the COMMAND mode, type HELP<cr>. Your display should list the following:
Help switches are:
ALL (Lists all settings).
CHANGE(List settings changed from factory default).
CONTROL (List settings dealing with control).
PLC(List settings for PLCs).
RADIO(List settings for ESTeem radio).
RS232(List settings for RS-232/422/485)
SETUP(List settings for control).
SYSTEM(List settings for system).
These are the different software categories.
Example: HELP SETUP<cr>, will list all the programmable variables and their settings for the SETUP category.
You can interrogate a discrete software command by just typing the command followed by a <cr>.
Figure 10: Test Radio Communication
Example: ADD<cr>, will list the current address saved in the connected ESTeem.
NoteAppendix E of this manual will have the complete listing of software commands and categories for the factory
default of the ESTeem.
Revised: 15 Oct 031-4 EST P/N AA104
CHAPTER 1
STARTING OUT
Saving A Program
A program is saved by typing in the SAVE command at the CMD: prompt. The programming variables that have been changed
will be written to the non-volatile memory. The programming parameters will be loaded each time the modem is powered up or
reset.
Restoring Factory Defaults
The ESTeem has a very simple procedure to restore the program variables in the unit to the factory default setting. When the
FA<Enter> command is entered from the command mode the ESTeem will be configured from a variable table located in its
EPROM. It is a good practice to restore the ESTeem to a factory defaults before any programming of the unit.
To ensure the modem is in the COMMAND MODE set it back to the factory default by performing the following:
1. Set both switches (#1&2) on the RS-232 setup switches to the OFF position.
2. Reset the ESTeem.
3. Verify the computer's Comm port is configured for 19,200,N,8,1.
4. Type FA<Enter> and the ESTeem welcome message should be displayed. The characters may not be echoed on the screen.
5. Type SA<Enter> to save the factory default table.
Revised: 15 Oct 031-5 EST P/N AA104
CHAPTER 2
MODES OF OPERATION
The ESTeem has three major modes of operation, Command, Converse, and Transparent. This chapter of the manual describes
each one of these modes.
COMMAND MODE
The COMMAND Mode (CMD: prompt) is the default mode that the ESTeem initially enters on power -up or after a hardware or
software reset. From this mode the user can command or program the ESTeem. In this mode the user may access the various
program commands to configure the ESTeem for the specific application. These values can be stored in nonvolatile memory
within the ESTeem by the use of the SAVE command. The ESTeem reads these setup parameters stored in memory on power-up
or RESET.
When programming in the COMMAND Mode, the user need only enter enough characters to uniquely identify the respective
command.
Example: CMD:ADD 15 <Enter>
This enters the source address of the ESTeem to the decimal value of 15. The first three letters ADD were enough for the
ESTeem to uniquely identify the command for ADDress. The number of characters that need to be typed varies depending
upon the command being entered. In some cases, four or even more letters may have to be entered in order for the identification
to be uniquely determined. Up to ten multiple commands can be written on the same line if separated by a colon.
Example: CMD:ADD 15:SETC 2:SAVE <Enter>
CONVERSE MODE
This mode allows bi -directional communication from the input/output device attached to the ESTeem to a destination ESTeem
and its respective input/output device. The ESTeem will automatically switch to the CONVERSE Mode after the initial
CONNECT has been made.
When the ESTeem is in the CONVERSE Mode the * prompt will be displayed. The ESTeem will remain in the CONVERSE Mode
until the radio link has been broken or by typing a control character defined by the user with the COMMAND variable.
The factory default for the COMMAND variable is CTRL C. You can return to the CONVERSE Mode from the COMMAND
Mode by typing CONV <Enter>.
When you are in the CONVERSE Mode the echoing of the character comes from the ESTeem if ECHO = ON (factory default) has
been programmed in the ESTeem.
Transmitting Data
The ESTeem will transmit data from the CONVERSE Mode if one or more of the following conditions have been met.
1.The ESTeem transmit buffer has been filled. The size of the transmit buffer is defined in the ESTeem by the PACKLEN
variable. This variable is programmable from 1 to 2000 bytes. Factory default is 2000.
2.The ESTeem receives a SENDPAC (send packet) character from the RS-232C input data stream. The SENDPAC variable can
be defined from 0 to 255 by the user. Factory default is 13 (carriage return). The SENDPAC character is also transmitted by
the ESTeem. In file dump applications the SENDPAC character can be programmed to be the EOF (end of file) character
transmitted from the sending device (i.e.; CTRL Z, CTRL G, etc.).
Revised: 15 Oct 032-1 EST P/N AA104
CHAPTER 2
MODES OF OPERATION
3.Termination control timer. The termination control timer is enabled by the TERMC (on/off) command. When enabled, the
termination timer starts from the time the last transmit buffer has been updated in the RS-232C port. If the termination timer
expires before another character is received or transmitted, the contents of the ESTeem transmit buffer will be transmitted.
The waiting time of the timer is defined by the TERMT variable (termination time). The programming range of the TERMT
variable is 10-65,535ms. Factory default values are TERMC = OFF and TERMT = 50. It is noted that when the termination
timer is used, the SENDPAC variable is usually programmed to be a character that is non occurring in your data stream (i.e.;
SENDPAC = 255) so that premature transmission does not occur.
TRANSPARENT MODE
The TRANSPARENT Mode allows the ESTeem to pass all data characters (O-255 or 0-FF hex) using 8 data bits.
To program the ESTeem in the TRANSPARENT mode the TRANSPARent command must be enabled and switch Bit 2 to ON
(RS-232C Setup Switch). The TRANSPARent command will defeat the SENDPAC and COMMAND variables and put the
ESTeem in the transparent mode when Bit 2 is ON.
The transmission of the data packets can only be accomplished by enabling the termination control commands (TERMC and
TERMT) or the PACKLEN buffer being filled. The value of TERMT should be slightly longer than the maximum delay
encountered during RS-232C transmission. If this time is set to short, the ESTeem will truncate your data stream improperly.
When using the TRANSPARENT Mode, data flow control is by hardware handshaking only. Hardware handshaking is initiated
by enabling hardware flow control (XHF = ON).
The SETCON (Set Connect command) must be used to define the node that you want to communicate with while in the
TRANSPARENT Mode. When the TRANSPARENT Mode is enabled you can not communicate to the ESTeem in the
COMMAND Mode unless you use the Hardware Mode Control line (see explanation this chapter).
To remove the ESTeem from the TRANSPARENT Mode the user must perform the following:
1.Switch Bit 2, Off on the RS-232C Setup Switch.
2.Reset the ESTeem from the front panel switch.
3. Type TRANS OFF <Enter>.
Revised: 15 Oct 032-2 EST P/N AA104
CHAPTER 2
MODES OF OPERATION
SEMI-TRANSPARENT MODE
This mode should be utilized when sending a non-ASCII file and there is a possibility that the SENDPAC character could be
contained in the transmitted data set. Perform the following prior to programming the ESTeem to initialize the unit to factory
default settings:
1.Turn Bit 2, OFF on the RS-232C Setup Switch.
2.Reset the ESTeem.
3.TYPE FA <Enter>. Please note the characters may or may not be echoed by the CRT.
ESTeem
-------------------------
ADDxxxxxx = your address
SETCyyyyyy = destination address
TERMCON
TERMT10
SENDP255
EDITOFF
XSFON
SAVE
If EDIT is off, and SENDPAC = 255, the SENDPAC character is disabled. This character when received will not cause packet
transmission and will be passed as normal data. The TERMC and TERMT commands are used to transmit the contents of the
ESTeem transmit buffer.
Software flow control in this example is enabled (factory default XSF = OFF) therefore the ESTeem will pass all characters except
the data flow control characters for Xon/Xoff.
HARDWARE MODE CONTROL
The MODECON (Mode Control) command is provided in the ESTeem to change the mode of the ESTeem modem from
COMMAND Mode to CONVERSE (or TRANSPARENT Mode) via a hardware control line. The hardware line is located on pin
19 of the RS-232C connector. If MODEC = ON, a "low or 0" on pin 19 (-3 to -15 vdc) will put the ESTeem in the COMMAND
Mode and a "high or one" on pin 19 ( +3 to +15 vdc) will put the ESTeem in the CONVERSE or TRANSPARENT Mode. The
factory default is OFF.
Revised: 15 Oct 032-3 EST P/N AA104
CHAPTER 3
PROGRAMMING
ESTEEM FEATURES
Listed in this chapter are the major ESTeem features and programming examples on how to use them. These features are
individual building blocks to solve your application needs. Remember your particular application may require one or more of
these features enabled.
DIGI-REPEATING
The Repeater feature allows an ESTeem to relay its respective transmission or packet through a maximum of three ESTeems to
increase the operating range of the unit. Any ESTeem in your radio network can function as a repeater for any other ESTeem.
This is independent of the fact that the ESTeem being used as a repeater is linked or connected to another node, therefore an
ESTeem can function as a repeater, operational node, or both at the same time. The data that is digi -repeated through ESTeem
will not output through the repeating ESTeem’s RS-232C port.
To specify one or more ESTeems as repeaters, the CONNECT command has been expanded to except up to three added
addresses as follows:
CONN r1,r2,r3,da
r1=Address (1 to 254) of first ESTeem repeater.
r2=Address (1 to 254) of second ESTeem repeater.
r3=Address (1 to 254) of third ESTeem repeater.
Da =Address (1 to 255) of destination ESTeem.
Note:Address 255 is used for Global.
When transmitting packets through other ESTeems, the source ESTeem will automatically adjust it's FRACK time to allow
additional time for the packet to reach its destination and for the returned acknowledgment. Frack time takes into account the
packet size and the number of repeaters specified. The ACK still comes from the destination ESTeem, not the first or any
repeater.
For testing purposes, you can loop back a connection to yourself by placing your source address in the destination address of
the repeater string. Any data transmitted will repeat through the repeater address and display back on the screen.
Example:
CONN r1,Sa
r1=Address (1 to 254) of first ESTeem repeater.
Sa =Address of local ESTeem.
Any ESTeem command in this manual that uses an address string can be configured to use the Digi-repeating feature.
Example:
SETC r1,r2,r3,da
Revised: 15 Oct 033-1 EST P/N AA104
CHAPTER 3
PROGRAMMING
ESTEEM FEATURES
GLOBAL BROADCAST
Global broadcast is the ability of one ESTeem to transmit it's message to more than one ESTeem at one time. All ESTeems within
radio range will receive the message whether or not they are connected to another ESTeem or in command or converse mode.
You can put your ESTeem in Global by connecting or programming the SETC to address 255. Address 255 is a non-assignable
unit address and is used by the ESTeem CPU to access this special mode. When the ESTeem is in Global, the standard ACK
protocol from the receiving ESTeem is disabled, but the 32 bit CRC error checking on the received ESTeem is still operational.
When you perform CONN 255 <Enter> from the COMMAND MODE the ESTeem will immediately go to the CONVERSE MODE
(* is displayed). All messages sent will be transmitted globally to all ESTeems in radio range.
In the ESTeem you have a GLOBAL (on/off) command. When GLOBAL = On, you can receive Global transmissions. If
GLOBAL = Off you will not display Global transmissions from other ESTeems.
Note: Factory default is ON.
By using the repeater function you can transmit Global messages from another ESTeem using the Digi-repeating feature.
Example:
CONN 10,20,30,255<Enter>
SETC 10,20,30,255<Enter>
By adjusting these commands you can route from unit 10 to 20, 20 to 30, and go Global at unit 30.
You can enable global transmissions in one or more ESTeem’s in your network. This will allow global communications between
all ESTeems within radio range.
AUTO TRANSMIT
The Auto Transmit feature of the ESTeem allows the user to transmit a data packet without filling up the PACKLEN (packet
length) buffer or defining a special control character using the SENDPAC (send packet) variable. The Auto Transmit feature is a
timer that is enabled in the ESTeem that monitors traffic in and out of the RS-232C port. If there are characters in the RS-232C
buffer, the termination control timer starts from the time the last receive or transmitted character is updated in the buffer. If the
termination time expires before another character is received or transmitted, the received characters are transmitted.
To enable this feature perform the following from the COMMAND MODE:
TERMC (on/off) =On. Enable termination control.
TERMT (10-65535) = One unit number equals 1ms.
TERMC is the termination control command. TERMT is the termination time command. Factory default for TERMC = Off and
TERMT = 50.
Revised: 15 Oct 033-2 EST P/N AA104
CHAPTER 3
PROGRAMMING
ESTEEM FEATURES
AUTO CONNECT
The Auto Connect feature allows the user to program the ESTeem to perform a CONNECT to another ESTeem when data is sent
to the RS-232C communications port.
To enable this feature perform the following from the COMMAND MODE:
SETCON (1-255) =Address of destination ESTeem.
Remember, you can use the Repeater routing (r1,r2,r3,da) or put the ESTeem in Global (address 255). SETCON is the set connect
command.
SASAVE command. This will save the SETC variable to the non-volatile memory so that it will not be lost when the
ESTeem is RESET.
Bit 2 (on/off) =On. Bit 2 is located on the RS-232C SETUP SWITCH on the front of the ESTeem. The ESTeem must be
RESET after the Bit has been changed to be read by the ESTeem CPU.
RESET ESTeem RESET is located on the front panel OFF/ON switch. The T/E light on the front panel of the ESTeem should
now flash at a two times per second rate.
Revised: 15 Oct 033-3 EST P/N AA104
CHAPTER 3
PROGRAMMING
ESTEEM FEATURES
MULTI-CONNECT
The actual polling of the ESTeem must originate from the host device connected to the ESTeem using the CONNECT command
to originate the initial connect and the COMMAND character to return from the CONVERSE mode to the COMMAND mode.
The first time around the pole a CONNECT data packet (RF transmission) will be initiated. When a link is established, it is held
internally in the ESTeem connect table. The next time around the pole to the same address, the link status will be checked in the
ESTeem table. If the address indicates a link has already been established, then only data and its corresponding ACK will be
transmitted to that node. This greatly increases polling time by eliminating the usual CONNECT/DISCONNECT sequence each
time except when communication is first established.
The MULTID command allows the user to send data to a specific ESTeem address from the CONVERSE Mode by specifying the
ESTeem address routing before the data packet. This feature will also display the address of the sending ESTeem on any
received data.
Example Of Transmitted Data:
[001]DATA Routes data to an ESTeem addressed 1.
[100,200,250,1]DATA Routes data to an ESTeem addressed 1 via ESTeems addressed 100, 200, and 250.
The above example replaces the CONNECT command from the COMMAND Mode.
Received data packets will have the address of the ESTeem that sent the data at the beginning of the data packet.
Example Of Received Data:
[004]RECEIVED DATAData received from ESTeem addressed 4.
[030,100,244,004] Data received from ESTeem addressed 4 via ESTeems addressed 30, 100, and 244.
MULTID (on/off) = OnEnables this feature. Factory default = OFF.
Revised: 15 Oct 033-4 EST P/N AA104
CHAPTER 3
PROGRAMMING
ESTEEM FEATURES
REMOTE PROGRAMMING
The Remote Programming feature allows the user to remotely program ESTeems in his network. When a connection has been
made with the remote ESTeem the RPG: prompt will be displayed showing that you are now in the COMMAND mode of that
remote ESTeem.
To enable this feature perform the following from the COMMAND MODE:
PROG (1-254)Address of destination ESTeem.
Note: You can also use the Repeater routing (r1,r2,r3,da) to reach the destination ESTeem. (r1 = address of first repeater,
r2 = address of second repeater, etc. da = destination address).
To end a remote programming session, hold Control and type C (^C) and you will return to the COMMAND prompt of your
ESTeem. There is a Watch Dog Timer that will automatically disconnect you from remote programming if there is no activity for
thirty seconds.
The REMPROG (on/off) feature is used to defeat the ability of your ESTeem from being remotely programmed. If REMPROG =
OFF another ESTeem cannot remotely program your unit. Factory default = ON.
SECURITY
The Security feature allows the user to lock out programming of the ESTeem. REMEMBER TO STORE YOUR CODE NUMBER
IN A SAFE PLACE.
To enable this feature perform the following from the COMMAND MODE:
SECURITY (1 to 100,000) Entering a security number enables the security feature.
SAVE To enter the security code permanently into the ESTeem memory.
Note: When enabled, the ESTeem will output a “Security On” message.
To disable the security feature perform the following from the COMMAND mode.
SECURITY (1 to 100,000) Entering your security number disables the security feature.
SAVETo remove the security code permanently from the ESTeem memory.
Note:When disabled, the ESTeem will output a “Security Off” message.
Revised: 15 Oct 033-5 EST P/N AA104
CHAPTER 3
PROGRAMMING
ESTEEM FEATURES
HARDWARE RING LINE (Factory Option)
When the ESTeem establishes a CONNECT or link with another ESTeem (T/E Light on solid), pin 22 at the ESTeem RS-232C will
change from a -15 vdc voltage state to a +15 vdc voltage state. The RING software command allows the user to change the
output from a latched state to a pulsed state. To change the state of this line program the following from the COMMAND
mode. Factory default = LATCH.
RING = Latch. Pin 22 is high when the ESTeem T/E light is on solid.
RING = Pulse. Pin 22 is pulsed (positi ve 250 ms.) when the ESTeem T/E light is on solid.
PACKET MONITOR
The PACKM [ON/OFF] command places the ESTeem in a special packet monitor mode. When this feature is enabled the
ESTeem is placed in a receive only mode and will not function as a normal ESTeem. The ESTeem will monitor and report the
status of all message traffic within the network in the following format, the actual packet message will not be outputted.
SA-xxx, DA-xxx, Type Code, R1-Repeater Status, R2-Repeater Status, R3-Repeater Status, Data Bytes Sent
xxx =ESTeem Address
DA =Destination ESTeem
SA =Source ESTeem
R1 =Address of first ESTeem repeater.
R2 =Address of second ESTeem repeater.
R3 =Address of third ESTeem repeater.
Type Codes
I= Information
DISC = Disconnected
RR= Receive Ready
UA = Unnumbered Acknowledge
RNR = Receive Not Ready
FRMR = Frame Reject
REJ= Reject
DM = Disconnected Mode
UI = Unnumbered Information
SABM = Set Async. Balance Mode
Repeater Status
P=Pending
D=Done
Revised: 15 Oct 033-6 EST P/N AA104
USING THE INFRARED COMMUNICATIONS PORT
CHAPTER 3
PROGRAMMING
ESTEEM FEATURES
The infrared (IR) communications port will allow you to
program and interrogate the ESTeem without
disconnecting the serial cable from the back of the
modem. The IR port is located on the front panel of the
ESTeem, above the T/E light.
To communicate from a computer to the ESTeem through
the IR port you will need a copy of the ESTeem Utilities
Antenna
ANTE
NNA
Model 192S
3 ft. Range
12 VDC
RESET
T/E
TX
RX
PWR
Phone
IR
S/N:
Port
RE
SET
(Version 4.0 or higher) and an ESTeem IR Communication
Dongle (ESTeem P/N AA300).
Connect the dongle directly to the serial port of the
computer. The dongle requires initialization from the
ESTeem Utilities. From the Terminal Emulation screen
press the F3 function key to initialize the dongle. If the
IR Communications Dongal
(EST p/n AA300)
Infrared Communications Port for
Remote Programming and Diagnostics
Without Interruption Of The Wireless
Radio Area Network
Figure 1: Using The IR Port
modem is not in the COMMAND mode, press CTRL-C to
display the CMD: prompt.
Note:With Switch 2 (RS-232 Setup) in the On position the ESTeem defaults the IR port to the command mode.
The IR dongle has a range of approximately three feet, directly in front of the port. The dongle is powered by the serial port and
requires no additional power sources.
Note:Only one of the three communications ports (RS-232/422/485 connector, IR port or Remote Programming) can be in
the Command mode at a time. When either the IR or the Phone port switch to converse mode, the RS-232/422/485
port is blocked from receiving any data.
Revised: 15 Oct 033-7 EST P/N AA104
CHAPTER 3
PROGRAMMING
ESTEEM FEATURES
UPDATING FLASH MEMORY
The ESTeem Model 192 stores its operating system in flash memory that can be updated without returning the modem the to the
factory. To upload the latest operating file, please contact Customer Support at 509-735-9092 or e-mail support@esteem.com to
request the latest flash memory update file for your product.
Once you receive the flash file from Customer Support, conduct the following steps to update the memory:
1. Open the ESTeem Utilities and select Terminal Emulation.
2. Verify that both switches (Bits 1 and 2) are in the down (OFF) position and reset the modem.
3. Select Terminal Setup>Port from the menu items and configure the computer serial port for 19,200,N,8,1.
Note:The flash update can not be loaded through the Infrared Dongle or remote programming. You must connect directly
to the ESTeem serial port.
4. Set the modem to factory defaults by entering FA <Enter>
at the command prompt (CMD:).
5. Select ESTeem Setup>Update Flash Memory from the
menu and the Utility will read information about the
connected modem and ask for the location of the flash file
(Figure 2). Browse to the location of the flash update file
on the computer and select Open.
6. Once the upload has been completed, re-program the
modem for operation.
Figure 2: Updating Flash Memory
Revised: 15 Oct 033-8 EST P/N AA104
CHAPTER 4
ESTEEM
APPLICATION PROGRAMS
Listed below are different application programs to aid the user in programming the ESTeem.
TRANSPARENT AUTO -CONNECT
This mode is used for a dedicated point to point application. The ESTeem will initiate the radio link when data is received by the
RS-232/422/485 port.
Perform the following prior to programming the ESTeem(s) to initialize the unit to factory default settings:
1.Turn Bit 2 OFF on the RS-232C Setup Switch.
2.Reset the ESTeem.
3.TYPE FA <Enter>. Please note the characters may not be echoed by the CRT.
ADDxxxADDyyy
SETCyyySETCxxx
TERMCONTERMCON
TERMT10TERMT10
XHFON *XHFON *
DISACKON *DISACKON *
TRANS ONTRANS ON
SAVESAVE
Bit 2 ON Bit 2 ON (RS-232 Switch)
Reset ESTeemReset ESTeem
Notes:
• Turn DISACK ON only if you want to defeat the acknowledge packet.
• xxx and yyy represent an ESTeem address which is user definable from 1 to 254.
Revised: 8 Oct 034-1 EST P/N AA104
CHAPTER 4
ESTEEM
APPLICATION PROGRAMS
TRANSPARENT AUTO -CONNECT GLOBAL
This mode is usually used for a point to multi -point applications when a customers devices include their own addressing
protocol to communicate between devices. The ESTeem packet addressing and acknowledge protocol is defeated. All ESTeems
will receive the data transmission. The 32 bit CRC error checking on received data is still enabled. This program is used in all
ESTeems, the only difference is the unit addresses.
Perform the following prior to programming the ESTeem(s) to initialize the unit to factory default settings:
1.Turn Bit 2 OFF on the RS-232C Setup Switch
2.Reset the ESTeem.
3.TYPE FA <Enter>. Please note the characters may not be echoed by the crt.
ADDxxx (xxx = ESTeem address)
SETCON255
TERMCON
TERMT10
XHFON *
TRANS ON
SAVE
Bit 2ON (RS-232 Switch)
Reset ESTeem
Note:Only hardware flow control can be used in this mode.
Revised: 8 Oct 034-2 EST P/N AA104
CHAPTER 4
ESTEEM
APPLICATION PROGRAMS
INTERACTIVE TERMINAL APPLICATION
This program is used to connect a mainframe to a remote terminal. This setup is a typical point to point configuration with the
AUTO-CONNECT feature enabled.
Perform the following prior to programming the ESTeem(s) to initialize the unit to factory default settings:
1.Turn Bit 2 OFF on the RS-232C Setup Switch.
2.Reset the ESTeem.
3.TYPE FA <Enter>. Please note the characters my not be echoed by the crt.
ADDxxxADDyyy
SETCyyySETCxxx
TERMCONTERMCON
TERMT10 TERMT10
XSFOFFXSFOFF
XHFON *XHFON *
DISACKON *DISACKON *
TRANS ONTRANS ON
SAVESAVE
Bit 2 ONBit 2 ON (RS-232 Switch)
RESET ESTeemRESET ESTeem
Notes:
• Turn DISACK ON only if you want to defeat the acknowledge packet.
• Only hardware flow control can be used in this mode.
• xxx and yyy represent an ESTeem address which is user definable from 1 to 254.
PROGRAMMABLE LOGIC CONTROLLERS
EST has available complete Engineering Reports for each PLC manufacturer make which will be provided at no charge by calling
EST Customer Support on 509-735-9092. All Engineering Reports are also available on the ESTeem Utility Resource Disk (EST
P/N AA109) in Adobe™ PDF format.
Revised: 8 Oct 034-3 EST P/N AA104
CHAPTER 5
RS-232C/422/485 INTERFACING
DTE vs. DCE
The ESTeem is configured as a Data Communication Equipment (DCE) device. The following signals are available at the
RS-232C connector located at the rear of the unit.
The important thing to remember is that for the ESTeem to communicate with an external device, the data output from pin 3 of
the ESTeem RS-232C connector must be connected to the data input of the device you are connected to; otherwise, the ESTeem
won't work. Likewise, the data input to pin 2 of the ESTeem must be connected to the data output of the device you are
connected to. Normally, if the equipment you are connecting to looks like a terminal or computer (DTE), its input, Receive Data
(RXD), will be on pin 3 its output, Transmit Data (TXD), will be on pin 2. Therefore, the ESTeem can be connected directly.
If the device you are connecting to is configured as a modem (DCE), its output will be on pin 3. If this configuration is
connected to the ESTeem, damage may result to the ESTeem or the connecting device. In this case, you can purchase a null
connector that internally reverses pins 2 and 3.
Whatever your situation may be, it is always best to check the manual on your particular device and connect accordingly.
Purchase or fabricate a RS-232C shielded cable for your ESTeem. The ESTeem requires a standard male 25 pin D connector on
one end of the cable for proper connection.
Remember to install the small retaining screws on either side of the cable connector. Tightening these screws keeps you from
accidentally losing connection with your ESTeem.
Notes:
•The ESTeem requires a shielded RS-232 cable. This is to prevent unwanted electrical noise from entering the ESTeem
and also to prevent any electrical noise from getting out of the ESTeem.
• Remember -- always use a shielded RS-232C cable.
• Pins 9, 10, 14, & 16 are used for RS-422/485 interfacing and should be left open if not used.
Revised: 8 Oct 035-1 EST P/N AA104
CHAPTER 5
RS-232C/422/485 INTERFACING
FLOW CONTROL
The ESTeem can be enabled to support SOFTWARE or HARDWARE flow control.
Software Flow Control
Software flow control is enabled by the XSFLOW (on/off) command in the ESTeem. When XSFLOW is ON the ESTeem will
respond to <XOFF>, (stop) and <XON>, (off) commands from the RS-232 port. The factory default setting is OFF. The default
value for START is 17 (CTRL Q) and for STOP is 19 (CTRL S).
Hardware Flow Control
Hardware flow control is enabled by the XHFLOW (on/off) command in the ESTeem. The factory default value is OFF.
When XHFLOW is enabled (on) the control signal lines, Request To Send (RTS, pin 4), Data Carrier Detect (DCD, pin 8), and
Clear To Send (CTS, pin 5) are available to the user at the RS-232C connector. The CTS and RTS signals are used to control the
flow of data into and out of the ESTeem.
The CTS signal on pin 5 is used to control the data into the ESTeem. When CTS is set (high on pin 5) the modem is ready to
receive data. When CTS is reset (low on pin 5) the ESTeem is not ready to receive data.
The RTS signal is used to control data out of the ESTeem. RTS is set (high on pin 4), by the user to indicate to the ESTeem that
the user is ready to receive data. When reset, the use r is not ready to receive data. (NOTE: Low = On, High = Off).
Revised: 8 Oct 035-2 EST P/N AA104
CHAPTER 5
RS-232C/422/485 INTERFACING
MEMORY BUFFERS
The ESTeem has a 4000 byte buffer on the TRANSMIT SIDE (outgoing data) and a 4000 byte buffer on the RECEIVE SIDE
(incoming data).
Transmit Buffer
The outgoing data buffer will hold two data blocks before the ESTeem will enable its RS-232C hardware/software flow control on
data coming into the modem if the network is busy. A data block in this example is a block of data that is defined by the
PACKLENGTH or SENDPAC character which ever occurs first.
Therefore, if PACKLENGTH = 10 the modem will input a maximum of 20 bytes before it enables its hardware/software handshake
line (two 10 byte packets). In another example, if PACKLENGTH = 2000 but the data block is terminated by the SENDPAC
character before the input buffer reaches the full 2000 bytes, the buffer will still hold only two data blocks if the network is busy.
In order to utilize the 2000 bytes storage for small data packets (bar code readers, etc.), program the modem using the following
guidelines:
PACKLENGTH= 2000SENDPAC= 255
TERMC= ONTERMT= 10
Note:Set the TERMT time greater than the pause between data bursts.
By programming the above parameters the ESTeem will buffer the incoming data packets and automatically transmit the data
when the 2000 byte buffer is filled or the TERMT time limit is met. This will allow the customer to use two blocks of 2000 or 4000
bytes before the modem enables the respect hardware/software control.
Receive Buffer
If the device that the receiving ESTeem is outputting data to, enables its respective hardware or software control, the modem will
store 4000 bytes of data before flow controlling off the transmitting ESTeem.
DATA TERMINAL READY (DTR)
A software switch, DTR_ENAB (ON/OFF) is provided in the ESTeem for monitoring the status of a device connected to pin 20
of the RS-232C connector. The factory default setting is OFF. When this command is enabled the ESTeem will monitor the DTR
signal on pin 20. If the DTR line being supplied to the ESTeem, from the user, is at a SPACE (high) condition then the ESTeem is
enabled. If the DTR line is at a MARK (low) condition then the ESTeem is disabled.
This signal is normally used by the ESTeem modem as an indication that connection is made to a device that is on line and ready
to transmit/receive data.
Revised: 8 Oct 035-3 EST P/N AA104
CHAPTER 5
RS-232C/422/485 INTERFACING
RS-422/485 CONFIGURATION
The ESTeem will support the requirements of the EIA Standard RS-422/485. This is a four (4) wire interface consisting of the
TRANSMIT DATA (-), TRANSMI T DATA (+), RECEIVE DATA (-), AND RECEIVE DATA (+) or a two (2) wire interface using
B (+) and A (-). These signals are available at the 25 pin RS-232C connector on the modem.
PinDescription
9BTR (-)TRANSMIT DATA (-)
DCE
(4-Wire)
10BTR (+)TRANSMIT DATA (+)
14BRX (+)RECEIVE DATA (+)
16BRX (+)RECEIVE DATA (-)
DCE
(2-Wire)
This interface is designed to provide unipolar differential drive to twisted pair or parallel wire transmission lines.
Note:The ESTeem is configured at the factory for RS-422 interfacing. RS-485 (either 4 or 2 wire mode) requires internal
jumper configuration. Please contact EST Customer Support at 509-735-9092 for instruction.
The ESTeem can be factory configured RS-485 interfacing prior to shipment. Call EST Customer Support on 509735-9092 for further details.
14(+)HALF-DUPLEX B (+)
16(-)HALF-DUPLEX A (-)
RS-232C/422/485 Configuration Tables
ESTeem RS-232C/422/485
On the front plate of the ESTeem is a two position RS-232 Setup switch
labeled SW. The switch positions are defined as follows:
RS-232C/422/485
SETUP SWITCH TABLE
BIT 1OFFDefault baud rate 19.2K, N, 8, 1
BIT 1ONUse software to select baud rate
BIT 2OFFEnter Command Mode upon
initialization
BIT 2ONEnter Conversation Mode upon
initialization
Note:*The ESTeem is configured at the factory for RS-422 interfacing.
RS-485 (2 or 4 wire) requires internal jumper configuration. Please
contact EST Customer Support at 509-735-9092 for instruction
Pin No.Function
1Shield Ground
2Transmit Data (TxD)
3Receive Data (RxD)
4Request To Send (RTS Input)
5Clear To Send (CTS)
6Data Set Ready (DSR)
7Signal Ground
8Data Carrier Detect (DCD)
19Mode Control
20Data Terminal Ready (DTR)
22Ring Indicator (RI)
12Request To Send (RTS Output)
9*RS-422/485 Transmit Data (-)
10*RS-422/485 Transmit Data (+)
14*RS-422/485 Receive Data (+)
16*RS-422/485 Receive Data (-)
Port Pin-Out Table
Revised: 8 Oct 035-4 EST P/N AA104
CHAPTER 5
RS-232C/422/485 INTERFACING
RS-232C/422/485 COMRATE Tables
The ESTeem Model 192 uses the COMRATE software command to set the communication port speed when Bit 1 on the RS-232
Setup Switches is in the ON position. The ESTeem Utility Program will calculate the required COMRATE value and download to
the ESTeem in Step 3 of the Starting Out Menu or by selecting ESTeem Setup>Configure ESTeem Serial Port from the Terminal
Emulation menu. If you would like to manually enter the command to set the serial port speed on the modem please use the
following table as a guideline:
EST offers different types of antennas ranging from ¼ wave to 5/8 wave in physical size. The user choice is dependent on the
application.
Communications in the VHF and UHF bands are normally over "Line of Sight (LOS)". Looking from the antenna of one wireless
modem you must be able to see the antenna of the wireless modem you wish to communicate with. If a large object obstructs the
line of sight view it is unlikely that satisfactory communications will result. This means you must relocate the antennas or use the
REPEATER FEATURE and a second modem to go over or around the object.
The Model 192C, CHP, F, M and MHP products are allowed by the FCC to use high gain directional antennas.
It is noted that a ¼ wave antenna that does not have ground plane radials requires a ground plane to operate at maximum
efficiency. This can simply be a conducting surface under the antenna that is a ¼ wavelength in diameter. For the Model 192C
(450-470 MHz) this is approximately 6.5 inches. A conducting surface can be anything from the rooftop of an automobile to a file
cabinet.
COAXIAL CABLES
To minimize signal loss, the overall length of the coaxial cable should be as short as possible. To avoid corrosion select coaxial
cable manufacturers with tinned copper braid, where possible. Listed below are representative cable losses in db/100ft at the VHF
and UHF frequencies:
Frequency
(MHz)
150-174 -5.2 -4.4 -1.7 -0.964 -0.88
402-420 -8.4 -7.8 -2.9 -1.72 -1.36
450-470 -9 -7.8 -3 -1.72 -1.45
In a severe noise environment it may be desirable to use a double shield type of coax cable such as RG-214/U.
Note: Pre-made coax cables can be purchased from the factory. A -3 dB loss means you have lost 1/2 of your signal. A +3 dB
gain means you have doubled (x2) your signal.
Keep the antenna feedline as short as possible to minimize losses.
Extreme care must be taken when attaching coax connectors to the antenna feedlines. If there is any error in making
this connection the output of the transmitter will be greatly reduced.
RG-58u
LMR 195
RG-8
(solid)
LMR600
1/2" Heliax
Revised: 28 Apr 11 6-1 EST P/N AA104
CHAPTER 6
ANTENNA SETUPS
WEATHER PROOFING COAX CONNECTIONS
1. Coat the threads of the connectors with silicone lubricant prior to assembly (See Note 1) and hand tighten. Care should be
taken not to get any lubricant on the center conductor.
2. Wrap the connector assembly with a non-adhesive silicone tape, EST part number AA243, for weather proofing (See Note 2).
Ensuring to overlap onto the coax cable approximately 1 1/2 inches and follow the instructions on the ESTeem AA243
technical bulletin.
3. Apply an electrical coating (sealing agent) over the vapor barrier patch for added protection (See Note 3).
Notes:
1. Dow Corning RTV-3140 or equivalent.
2. CoaxWrap, CW10B or equivalent.
3. SCOTCHKOTE, 3-M Company, or equivalent.
GROUNDING
All building mount antennas require attachment to a good earth ground for optimum efficiency. Contact a reputable local
communications shop for procedures for your area.
LIGHTNING ARRESTORS
Lightning arrestors should be used on all external building mount antennas for personal protection and to minimize damage to the
transceiver during lightning storms. The units should be installed as per manufacturers instructions provided with the device.
REFERENCE MATERIAL
The ideal reference book for antennas and transmission lines is the “The Radio Amateur's Handbook”, by the Headquarters Staff of
the American Radio Relay League.
Revised: 28 Apr 11 6-2 EST P/N AA104
CHAPTER 6
ANTENNA SETUPS
Revised: 28 Apr 11 6-3 EST P/N AA104
CHAPTER 6
ANTENNA SETUPS
Revised: 28 Apr 11 6-4 EST P/N AA104
CHAPTER 6
ANTENNA SETUPS
Revised: 28 Apr 11 6-5 EST P/N AA104
CHAPTER 6
ANTENNA SETUPS
Revised: 28 Apr 11 6-6 EST P/N AA104
CHAPTER 6
ANTENNA SETUPS
Revised: 28 Apr 11 6-7 EST P/N AA104
CHAPTER 6
ANTENNA SETUPS
Revised: 28 Apr 11 6-8 EST P/N AA104
CHAPTER 6
ANTENNA SETUPS
Revised: 28 Apr 11 6-9 EST P/N AA104
CHAPTER 6
ANTENNA SETUPS
Revised: 28 Apr 11 6-10 EST P/N AA104
CHAPTER 6
ANTENNA SETUPS
Programming The ESTeem Model 192 For SWR Measurements
1. Configure the hardware as per the above diagram.
2. Turn Switch 2 on the RS-232 Setup Switch (located on the rear of the ESTeem) to the OFF position.
3. Reset the ESTeem (front panel push button).
4. Install the ESTeem Utility on the PC hard drive as per instructions
with the software.
5. From Utility Main Menu (Figure 1) select the Terminal Emulation
Mode.
6. In the Terminal Emulation Mode type the following commands
followed by a RETURN.
FA Return This returns the unit to factory default
parameters.
RAD ON Return Enable the RADIO ON command. The
transmitter will alternate ON for 10 seconds (5
seconds for 192CHP) and OFF for 3 seconds .
7. When the testing is completed, type the following:
RAD OFF Return This disables the RADIO ON command
Figure 1: ESTeem Utility Main Menu
Revised: 28 Apr 11 6-11 EST P/N AA104
CHAPTER 7
THEORY OF OPERATION
INTRODUCTION
ESTeem wireless modem products provide a "Wireless Solution" by eliminating conventional hardwiring of leased phone lines.
All of the ESTeem models come with the industry standard RS-232C, RS-422, and RS-485 asynchronous communications ports
to give the user a new dimension to "Local Area Networking".
Our packet burst, frequency agile communications products allow the user to create a "Radio Area Network" of up to 255 users
on a single frequency. The packet burst communications technique was chosen to give the system very high data integrity in
high noise industrial environments. The ESTeem incorporates a method of error checking that provides received data accuracy
of greater than one part in 100 million.
Internal Digi -Repeater features allow the user to increase operating range by relaying transmission through a maximum of three
ESTeems to reach the destination ESTeem. An ESTeem can operate as an operating node, a repeater node, or both
simultaneously for added flexibility.
"Private Data Communications" is provided by the use of an interleaving technique of the modulated data, user definable
commands for unit addressing, network addressing, and security lock-out of software programming. If higher security is
required, the ESTeem is compatible with asynchronous Data Encryption Standard (DES) encryption devices.
The ESTeem has programmable software commands to allow the user to easily configure the unit for any application or mission.
The ESTeem setup parameters are saved in non-volatile memory.
When you buy ESTeem products you are getting equipment designed by the company that holds the United States and
Canadian patent for the wireless modem. We are proud to say that we design, develop and manufacture our products in the
United States. Each ESTeem is subjected to a rigorous quality control bench test before shipping to insure our customers have
out-of-the-package reliability. We also have a dedicated Customer Support Staff, Field Engineering Services and Factory
Training classes to make sure that your application problems are solved.
HOW IT WORKS
Now, as you can probably guess, the ESTeem is a sophisticated piece of technology, however the concept is easy to
comprehend if you understand packet radio.
All packet systems, whether hardwired or radio, share the same principle of operation; data is taken from your standard RS-232C,
RS-422, or RS-485 asynchronous port and is transmitted in "Blocks". Think of this block as an "Electronic Envelope" that we
call a packet. The size of the packet can be defined by the user from 1 to 2000 bytes of information. Reducing the size of the
packet allows the ESTeem to operate better in high EMF noise environments, because by reducing the packet size you reduce
transmission exposure time on the radio waves thereby increasing your probability of a successful transmission.
Once this packet of data is formed, it’s transmitted in a "burst," one ESTeem to another, hence the term "packet burst
communications". Now, if more than one packet is required to send the data then the ESTeem goes into full automatic mode and
transmits additional packets.
Before an ESTeem transmits its packet it listens to ensure that the air waves are clear before transmitting. This listen before
transmit scheme is called "carrier sensed multiple access," or CSMA.
When a "packet" has been transmitted, every modem in radio range on the same frequency hears it. To design a modem to
communicate with a network of modems it has to be "address specific" so only the modem you want to talk to accepts your
information. It's like yelling into a crowd of 255 people but you want only the person’s name you called to acknowledge (ACK).
Revised: 9 Oct 037-1 EST P/N AA104
CHAPTER 7
THEORY OF OPERATION
Well, very simply, that's how the ESTeem works. Once the address you're calling receives your packet, it's checked for
accuracy.
Accuracy is probably the single most important part of any communication device. The ESTeem uses Forward Error Correction
(FEC) and a 32 bit Cyclic Redundancy Check (CRC) which is a very sophisticated method of checking the data integrity of the
packet once its been received. The CRC insures data integrity greater than one part in one hundred million. Once the CRC is
completed on the received packet, the data is outputted to the user and a positive acknowledgment (ACK) is transmitted back to
the sender.
It's safe to assume that the data you receive is good data or you get nothing at all using the CRC technique. If no ACK is
returned after a given delay, the sender assumes the packet was not received and "retries" the transmission. The number of
retries are user definable from 1 to 255, allowing the unit to automatically retry sending the packet.
SPECTRUM UTILIZATION
The ESTeem uses a "listen before transmit" or Carrier Sensed Multiple Access (CSMA) scheme. This means only one unit in a
network is allowed to transmit at a time. By fixing each user's communication window and allowing the computer in the ESTeem
to be the Air Traffic Controller, many individual users can share one frequency. The ESTeem firmware can support up to 255
ESTeems on a single channel or frequency. For example in the United States there are 1600 frequencies (12.5 kHz channel
spacing) in UHF, giving a network density of greater than 408,000 users in a given cell or geographical area. Once you are out of
radio range, you can construct another cell of users.
The CSMA technique is a very efficient way to manage your network of ESTeems and prevent communication bottlenecks. In
addition, an anti -collision software scheme is used to recover data if two or more units transmit at exactly the same time. When
this feature is added the technical term for this technique is now called CSMA-CD (collision detection).
By using this communications technique only one frequency channel is needed with a very narrow bandwidth (this is called
narrow band FM modulation) thereby saving valuable radio spectrum space.
PACKET PROTOCOLS
By using CSMA no polling station or token is required in the ESTeem network. When an ESTeem has information to send it will
check to see if the channel is clear before transmitting its packet and await an (ACK). The ESTeem is a Master/Master system,
meaning any ESTeem can communicate with any other ESTeem.
FLOW CONTROL
The ESTeem supports hardware and software flow control, which allow different devices on the network to communicate at
different baud rates. In addition to flow control the ESTeem also has a 4000 byte data buffer on both the receive and transmit
buffers in the unit.
DATA PRIVACY
Data privacy in the ESTeem is provided by three levels of data encoding in the firmware and by the user being able to define
over four security and communications parameters (Unit Address, Network ID, and Operating Frequency) that allow
communications access to the modem giving over 100 million combinations. If higher security is required, the units are
compatible with asynchronous Data Encryption Standard (DES) encryption peripherals.
Revised: 9 Oct 037-2 EST P/N AA104
CHAPTER 7
THEORY OF OPERATION
EFFECTIVE BAUD RATE
The maximum input baud rate to the modem is 19,200 baud, asynchronous, full duplex, but this is misleading since the ESTeems
actually communicate to each simplex over the RF link, at 19,200 bps (25 kHz channel spacing - Model 192C/F) or 9,600 bps (12.5
kHz channel spacing - Model 192C/F). The effective baud rate is a function of the above plus the packet length variable in the
ESTeem (definable from 1 to 2000 bytes). If the packlength variable is set to 2000 bytes the effective baud rate is approximately
18,000 baud (25 kHz channel spacing) or 9,000 baud (12.5 kHz channel spacing) the effective baud rate will degrade as the
packlength variable is reduced.
Another item that must be understood is transmission turn around time. Remember that the ESTeem sends a data packet and
waits for an (ACK) from the destination modem before another packet is transmitted. All radio transmitters have a fixed delay
time, this is the amount of time it takes the transmitter to stabilize once it is energized before it can send data. In the ESTeem the
delay is approximately 15 milliseconds one way which includes transmitter turn-on time and packet frame overhead or a total turn
around time accounting for the (ACK) of 30 milliseconds. Therefore total time to send a data packet is 30 milliseconds plus the
time required to send the data (i.e. number of bits sent/19,200 b/s).
Revised: 9 Oct 037-3 EST P/N AA104
APPENDIX A
FCC INFORMATION
INFORMATION TO USERS
WARNING: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generated, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in
which case the user will be required to correct the interference at his own expense.
To insure compliance to FCC non-interference regulations, peripherals attached to this modem require shielded I/O
cables.
If this equipment does cause interference to radio or television, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following measures:
1.Re-orient the radio/TV-receiving antenna.
2.Re-orient the modem antenna.
3.Relocate the modem with respect to the radio/TV-receiving antenna.
4.Plug the power supply for the modem into a different outlet so that the modem and radio/TV receiver are on different branch
circuits.
5.Verify that the modem chassis is connected to an earth ground.
6.Attach a split bead (FAIR-RITE PN 2643164251) to the RS-232 cable.
If necessary, the user should consult the dealer or an experienced radio/TV technician for additional suggestions. The user may find
the following booklet prepared by the FCC helpful.
"How to Identify and Resolve Radio-TV Interference Problems"
This booklet is available from the U.S. Government Printing Office, Washington, D.C. 20402 - Stock No. 004-000-00245-4.
Application forms for the license are available from the nearest office of the FCC.
Electronic Systems Technology maintains a list of consultants that provide professional services at a reasonable cost to assists the
users in licensing.
1011 E. Tudor Rd.
Rm 240 Box 2955
Anchorage, AK 99510
CALIFORNIA
7840 El Cajon Blvd
Suite 405
La Mesa, CA 92041
3711 Long Beach Blvd
Suite 501
Long Beach, CA 90807
323A Battery St
San Francisco, CA 94111
COLORADO
Executive Tower
1405 Curtis St
Suite 2925
Denver, CO 80202
FLORIDA
919 Federal Bldg
51 SE First Ave.
Miami, FL 33130
1211 N. Westshore
Suite 601
A.D. P. Building
Tampa, FL 33607
GEORGIA
Massell Bldg. 440
1365 Peachtree NE
Atlanta, GA 30309
HAWAII
7304 Prince Kuhi
Federal Building
Honolulu, HI
HAWAII
300 Almoana Blvd.
P.O. Box 50023
Honolulu, HI
ILLINOIS
3935 Federal Bldg
230 S. Dearborn
Chicago, IL 60604
LOUISIANA
1009 Edw Hebert Bldg.
600 South Street
New Orleans, LA 70130
MARYLAND
1017 Geo. Fallon
Building 31
Hopkins Plaza
Baltimore, MD
MASSACHUSETTS
1600 Customhouse
165 State Street
Boston, MA 02109
MICHIGAN
1054 Federal Building
231 W LaFayette
Detroit, MI 48225
MINNESOTA
691 Federal Building
316 N Robert St.
St. Paul, MN
MISSOURI
Brywood Office Tower
6800 E. 63rd Street
Kansas City, MO
NEW YORK
1307 Federal Building
111 W. Huron
Buffalo, NY 14202
201 Varick Street
New York, NY 10014
OREGON
1782 Federal Building
1220 SW 3rd Avenue
Portland, OR 97204
PENNSYLVANIA
Room 404
2300 E. Lincoln H
Langhorne, PA
PUERTO RICO
747 Federal Building
Carlo Chardon Ave.
Hato Rey, PR 00918
TEXAS
Cabeli Building
1100 Commerce
Dallas, TX 75242
5636 Federal Building
515 Rusk Avenue
Houston, TX 77002
VIRGINIA
Military Circle
870 N. Military Hwy.
Norfolk, VA 23502
WASHINGTON
3256 Federal Building
915 Second Avenue
Seattle, WA 9817
Revised: 14 Apr 05APX A-3EST P/N AA104
APPENDIX B
SPECIFICATIONS
Model 192C/CHP/F/M Overall Specifications
SWITCHES:
• CPU Reset
• RS-232C/422/485 Setup
LED INDICATORS:
• Power On
• Receiver Carrier Detect
• Transmitter Enable
• Link Connect/Disconnect
• Auto Connect Enabled
• RS-232C/422/485 Framing Error
I/O - CONNECTORS:
•Asynchronous Full Duplex,
RS-232C, RS-422 and RS 485
with 25 Pin Sub D Connector.
•Antenna Output - TNC
connector
•Input Power - 2 pin molex
ADDRESSING RANGE:
• 1 to 255
DATA INPUTS:
DATA BUFFERS:
• Transmit 4000 bytes
• Receive 4000 bytes
FLOW CONTROL:
• Hardware or Software
DATA TRANSMISSION
PROTOCOL:
•Carrier Sensed Multiple Access
with Collision Detection
(CSMA-CD)
ERROR CHECKING:
Forward error correction and 32 Bit
Cyclic Redundancy Check (CRC)
with packet acknowledge and retry
MINIMUM RADIO TURN
AROUND TIME:
• < 15 ms + Data (W/O ACK)
• < 30 ms + Data (W/ACK)
POWER REQUIREMENTS:
Models 192C & 192F
• 10.8 to 16 VDC @ 400 ma Rx
2 W RF 1.5 A Tx
4 W RF2.0 A Tx
Models 192CHP & 192MHP
• 10.8 to 16 VDC @ 400 ma Rx
10 W RF 4.0 A Tx
20 W RF 5.5 A Tx
30 W RF8.5 A Tx
Model 192M
• 10.8 to 16
VDC @ 400 ma Rx
2 W RF 1.5 A Tx
4 W RF 2.0 A Tx
SIZE:
• 2.45 in. Height
• 9.37 in. Width
• 8.16 in. Length
WEIGHT:
• Selectable 600 to 19,200 baud
• 7 to 8 data bits
• Even, odd, or no parity
• One or two stop bits
• 5 lbs.
ENVIRONMENT:
• -30 TO 50 ° C.
• 95% non-condensing
WARRANTY:
•1 Year
Revised: 13 Apr 05APX B- 1EST P/N AA104
APPENDIX B
SPECIFICATIONS
Model 192C/CHP/F/M/MHP Overall Specifications
ESTeem Model 192CESTeem Model 192CHP
Frequency Range450 to 470 MHz450 to 470 MHz
Frequency SelectionDigitally Synthesized - Software SelectableDigitally Synthesized - Software Selectable
Frequency Stability+/- 1 ppm+/- 2.5 ppm
Frequency Selectability6.25KHz6.25KHz
RF Data Rate
Transmitter ModulationDC to 4800 Hz @ 19,200 bpsDC to 4800 Hz @ 19,200 bps
Transmitter RF Power Output
Transmitter Duty Cycle100%100%
Transmitter Spurious & Harmonics> 55 dB down from carrier> 55 dB down from carrier
Transmitter Rise Time1 msec1 msec
Receiver Sensitivity:-101 dBm @ 12 dB Sinad-110 dBm @ 12 dB Sinad
Receiver Spurious & Image Rejection> 50 dB> 50 dB
Receiver Squelch SensitivitySoftware AdjustableSoftware Adjustable
Receiver Adjacent Channel Rejection> 70 dB> 70 dB
Receiver Modulation Acceptance:
Receiver Base Bandwidth:
Transmit/Receive SwitchIntegral to UnitIntegral to Unit
RF Output Impedance50 Ohms50 Ohms
RF Input/Output ConnectorTNC FemaleTNC Female
Power Supply Voltage10.8 to 16 VDC10.8 to 16 VDC
Power Supply Current @ 12 VDC
Input Power Connector2 Pin Molex (male)2 Pin Molex (male)
Temperature Range
Size2.45 in. H x 9.37 in. W x 8.16 in. L.2.45 in. H x 9.37 in. W x 8.16 in. L.
Weight5 lbs.5 lbs.
19,200 bps @ 25 KHz Channel Spacing
U.S.A. Type Acceptance: ENPESTEEM192
Emission Designator: 17K6F1D
9,600 bps @ 12.5 KHz Channel Spacing
U.S.A. Type Acceptance: ENPESTEEM192A
Emission Designator: 10K8F1D
19,200 bps @ 12.5 KHz Channel Spacing
Canada: 2163 195 214A
Emission Designator: 10K0F2D
DC to 2400 Hz @ 9,600 bpsDC to 2400 Hz @ 9,600 bps
3 KHz @ 9,600 bps2.5 KHz @ 9,600 bps
2 Watts
(4 Watts optional)
25 KHz @ 19,200 bps
12.5 KHz @ 9,600 bps
4.8 KHz @ 19,200 bps
2.4 KHz @9,600 bps
400 ma Receive
1.5 A Transmit @ 2 W RF Output
2.0 A Transmit @ 4 W RF Output
-30 to + 50 ° C.-30 to + 50 ° C.
19,200 bps @ 25 KHz Channel Spacing
F.C.C.: ENPESTEEM192CHP
Canada: 2163192CHP
Emission Designator: 16K6F2D
9,600 bps @ 12.5 KHz Channel Spacing
F.C.C.: ENPESTEEM192CHP
Canada: 2163A-EST192CHP
Emission Designator: 9K80F2D/16K6F2D
10,20, 30 or 30 watts
(Software Selectable)
25 KHz @ 19,200 bps
12.5 KHz @ 9,600 bps
4.8 KHz @ 19,200 bps
2.4 KHz @9,600 bps
400 ma Receive
4.0 A @ 10 W RF Output
5.5 A @ 20 W RF Output
8.5 A @ 30 W RF Output
Revised: 13 Apr 05APX B- 2EST P/N AA104
Model 192C/CHP/F/M/MHP Overall Specifications
ESTeem Model 192F
Frequency Range400 to 420 MHz
Frequency SelectionDigitally Synthesized - Software Selectable
Frequency Stability+/- 1 ppm
Frequency Selectability6.25KHz
RF Data Rate
Transmitter ModulationDC to 4800 Hz @ 19,200 bps
Transmitter Deviation 4 KHz @ 19,200 bps
Transmitter RF Power Output
Transmitter Duty Cycle100%
Transmitter Spurious & Harmonics> 55 dB down from carrier
Transmitter Rise Time1 msec
Receiver Sensitivity:-101 dBm @ 12 dB Sinad
Receiver Spurious & Image Rejection> 50 dB
Receiver Squelch SensitivitySoftware Adjustable
Receiver Adjacent Channel Rejection> 70 dB
Receiver Modulation Acceptance:
Receiver Base Bandwidth:
Transmit/Receive SwitchIntegral to Unit
RF Output Impedance50 Ohms
RF Input/Output ConnectorTNC Female
Power Supply Voltage10.8 to 16 VDC
Power Supply Current @ 12 VDC
Input Power Connector2 Pin Molex (male)
Temperature Range
Size2.45 in. H x 9.37 in. W x 8.16 in. L.
Weight5 lbs.
19,200 bps @ 25 KHz Channel Spacing
Canada: 2163 195 214A
Emission Designator: 17K6F1D
9,600 bps @ 12.5 KHz Channel Spacing
Canada: 2163 195 214A
Emission Designator: 10K8F2D
DC to 2400 Hz @ 9,600 bps
3 KHz @ 9,600 bps
4 Watts
(2 Watts optional)
25 KHz @ 19,200 bps
12.5 KHz @ 9,600 bps
4.8 KHz @ 19,200 bps
2.4 KHz @9,600 bps
400 ma Receive
1.5 A Transmit @ 2 W RF Output
2.0 A Transmit @ 4 W RF Output
-30 to + 50 ° C.
APPENDIX B
SPECIFICATIONS
Revised: 13 Apr 05APX B- 3EST P/N AA104
APPENDIX B
SPECIFICATIONS
Model 192C/CHP/F/M/MHP Overall Specifications
ESTeem Model 192MESTeem Model 192MHP
Frequency Range150 to 174 MHz150 to 174 MHz
Frequency SelectionDigitally Synthesized - Software SelectableDigitally Synthesized - Software Selectable
Frequency Stability+/- 2.5 ppm+/- 2.5 ppm
Frequency Selectability6.25KHz6.25KHz
19,200 bps @ 25 KHz Channel Spacing
U.S.A. Type Acceptance:
ENPESTEEM192M
Emission Designator: 17K6F2D
19,200 bps @ 25 KHz Channel Spacing
F.C.C.: ENPESTEEM192MHP
Canada: TBD
Emission Designator: 16K6F2D
9,600 bps @ 12.5 KHz Channel Spacing
U.S.A. Type Acceptance:
RF Data Rate
19,200 bps @ 25 KHz Channel Spacing
9,600 bps @ 12.5 KHz Channel Spacing
Transmitter ModulationDC to 4800 Hz @ 19,200 bpsDC to 4800 Hz @ 19,200 bps
Transmitter RF Power Output
Transmitter Duty Cycle100%100%
Transmitter Spurious & Harmonics> 55 dB down from carrier> 55 dB down from carrier
Transmitter Rise Time1 msec1 msec
Receiver Sensitivity:-101 dBm @ 12 dB Sinad-110 dBm @ 12 dB Sinad
Receiver Spurious & Image Rejection> 50 dB> 50 dB
Receiver Squelch SensitivitySoftware AdjustableSoftware Adjustable
Receiver Adjacent Channel Rejection> 70 dB> 70 dB
Receiver Modulation Acceptance:
Receiver Base Bandwidth:
Transmit/Receive SwitchIntegral to UnitIntegral to Unit
RF Output Impedance50 Ohms50 Ohms
RF Input/Output ConnectorTNC FemaleTNC Female
Power Supply Voltage10.8 to 16 VDC10.8 to 16 VDC
Power Supply Current @ 12 VDC
Input Power Connector2 Pin Molex (male)2 Pin Molex (male)
Temperature Range
Size2.45 in. H x 9.37 in. W x 8.16 in. L.2.45 in. H x 9.37 in. W x 8.16 in. L.
Weight5 lbs.5 lbs.
ENPESTEEM192M
Emission Designator: 10K8F2D
Canada: 2163 195 385A
Emission Designator: 17K6F2D
Canada: 2163 195 385A
Emission Designator: 10K8F2D
DC to 2400 Hz @ 9,600 bpsDC to 2400 Hz @ 9,600 bps
3 KHz @ 9,600 bps2.5 KHz @ 9,600 bps
2 Watts
(4 Watts optional)
25 KHz @ 19,200 bps
12.5 KHz @ 9,600 bps
4.8 KHz @ 19,200 bps
2.4 KHz @9,600 bps
400 ma Receive
1.5 A Transmit @ 2 W RF Output
2.0 A Transmit @ 4 W RF Output
-30 to + 50 ° C.-30 to + 50 ° C.
9,600 bps @ 12.5 KHz Channel Spacing
F.C.C.: TBD
Canada: TBD
Emission Designator: 9K8F2D
10,20 or 30 watts
(Software Selectable)
25 KHz @ 19,200 bps
12.5 KHz @ 9,600 bps
4.8 KHz @ 19,200 bps
2.4 KHz @9,600 bps
400 ma Receive
4.0 A @ 10 W RF Output
6.5 A @ 20 W RF Output
8.5 A @ 30 W RF Output
Revised: 14 Sep 05APX B- 4EST P/N AA104
APPENDIX B
SPECIFICATIONS
Model 192C/CHP/F/M/MHP Case Diagram
Revised: 13 Apr 05APX B- 5EST P/N AA104
Model 192C/CHP/F Antenna Specifications
Model No:AA19C & AA19F
Antenna Type:Omni-Directional, ½ Wave
Applications:Mobile Mount.
Frequency:450 to 470 MHz - AA19C
400 to 420 MHz - AA19F
Polarization:Vertical
Impedance:50 ohms
Gain:2 db.
VSWR:< 2 to 1
Front To Back Ratio:n/a
Horizontal Beamwidth:n/a
Vertical Beamwidth: 60 degrees
Antenna Material:Rubber duck whip.
Mounting Hardware: Magnetic base.
Antenna Connector:TNC with 12 feet integral RG-58 cable.
Antenna Envelope:16 in. length. Magnetic base 3.5 in. by 3 in by 1 in.
Weight: 1 lb. 5 oz.
APPENDIX B
SPECIFICATIONS
Model AA19C/F
Model No:AA20C & AA20F
Antenna Type:Omni-Directional, DC grounded, Collinear 5/8 wave over 1/2 wave.
Applications:Fixed base or mobile mounting. L shaped mounting
bracket may be removed for panel mounting. Ground
plane radials may be removed depending on application.
Frequency:450 to 470 MHz - AA20C
400 to 420 MHz - AA20F
Polarization:Vertical
Impedance:50 ohms
Gain:4.5 dB.
VSWR:< 1.5
Front To Back Ratio:n/a
Horizontal Beamwidth:n/a
Vertical Beamwidth: 30 degrees
Antenna Material:Stainless steel whip and ground plane radials. All other
hardware anodized metal.
Mounting Hardware:Stainless steel clamps for mounting to ¾ in. to 1 /2 in.
pipe with right angle mount or direct mount.
Antenna Connector:UHF Female (S-239)
Antenna Envelope:37 ½ in. length by 16 in width with ground plane radials.
Weight: 2 lbs.
Model AA20C/F
Revised: 13 Apr 05APX B- 6EST P/N AA104
APPENDIX B
SPECIFICATIONS
Model 192C/CHP/F Antenna Specifications
Model No:AA202C & AA202F
Antenna Type:Directional, DC grounded, 5 element yagi.
Applications:Fixed base.
Frequency:450 to 470 MHz - AA202C
400 to 420 MHz - AA202F
Polarization:Vertical or Horizontal
Impedance:50 ohms
Gain:10 dB
VSWR:< 1.5
Front To Back Ratio:20 dB
Horizontal Beamwidth:59 degrees
Vertical Beamwidth: 53 degrees
Antenna Material:High strength aluminum with gold chromate finish.
Mounting Hardware: Heavy duty U bolts for mounting up to 2 1/8 in. pipe with right angle mount or direct panel
mount.
Antenna Connector:UHF Female (SO-239)
Maximum Power Input:300 Watts
Antenna Envelope:34.5 in. length by 13.25 in. width
Windload (RWV):100 mph
Weight:1.68 lbs.
Model AA202C/F
Revised: 13 Apr 05APX B- 7EST P/N AA104
Model 192M/MHP Antenna Specifications
1 in.
3 in.
3.5 in.
12 ft.
RG-8 Cable
Male
TNC
9.5 in.
Whip
Drawing Not
To Scale
Model AA19M
Model No:AA19M
Antenna Type:Omni-Directional, ½ Wave over ¼ Wave.
Applications:Mobile Mount.
Frequency:150 to 174 MHz
Polarization:Vertical
Impedance:50 ohms
Gain:Unity
VSWR:< 1.5 to 1
Front To Back Ratio:n/a
Horizontal Beamwidth:n/a
Vertical Beamwidth: 60 degrees
Antenna Material:Rubber duck whip.
Mounting Hardware: Magnetic base.
Antenna Connector:TNC with 12 feet integral RG-58 cable.
Antenna Envelope:11 in. length. Magnetic base 3.5 in. by 3 in. by 1 in.
Weight: 1 lb. 5 oz.
APPENDIX B
SPECIFICATIONS
Model No:AA20M
Antenna Type:Omni-Directional, DC Grounded, 5/8 Wave.
Applications:Fixed base or mobile mounting. L shaped mounting
bracket may be removed for panel mounting.
Ground plane radials may be removed depending on
application.
Frequency:150 to 175 MHz
Polarization:Vertical
Impedance:50 ohms
Gain:3.0 dB with ground plane radials
VSWR:< 1.5
Front To Back Ratio:n/a
Horizontal Beamwidth:n/a
Vertical Beamwidth: 60 degrees
Antenna Material:Stainless steel whip and ground plane radials. All
other hardware anodized metal.
Mounting Hardware:Stainless steel clamps for mounting to .75 in. to 1.5
in. pipe with right angle mount or direct panel mount.
Antenna Connector:UHF Female (SO-239)
Antenna Envelope:61 in. length by 43.5 in. width with ground plane radials
Power: 200 watts
Weight: 2 lbs.
Drawing Not To Scale
21 in.
5/16 in.
Diameter
52 in.
9 in.
1.5 in.
Model AA20M
Revised: 13 Apr 05APX B- 8EST P/N AA104
SPECIFICATIONS
Model 192M/MHP Antenna Specifications
Model:AA202M
Antenna Type:Directional, 3 Element Yagi, DC Ground
Applications: Fixed base mounting.
Frequency:150 to 174 MHz
Polarization:Vertical or Horizontal
Impedance:50 ohms
Gain:7.1 dB
VSWR:< 1.5
Front To Back Ratio:17 dB
Horizontal Beamwidth:72 degrees
Vertical Beamwidth: 57 degrees
Antenna Material:6061-T6 Aluminum
Boom Diameter: 7/8 in. 6061-T6 Aluminum, double wall construction
Mounting Hardware: Stainless steel U bolts for mounting to 1 5/8 in. diameter pipe.
Antenna Connector:UHF Female (SO-239)
Maximum Power Input:500 Watts
Antenna Envelope:42 in. length by 39 in. width
Windload (RWV):100 mph
Wind Load, Flat Plate (Ft 2 ): .36 sq. ft.
Lateral Thrust @ RWV:14.6 lbs.
Bending Moment @ RWV: 25.3 ft. lbs.
Weight:3 lbs.
APPENDIX B
Model AA202M
Revised: 13 Apr 05APX B- 9EST P/N AA104
APPENDIX C
ESTeem MESSAGE TABLES
ESTeem Command Error Messages
Listed below are the ESTeem Command Error Messages and their definitions. To receive these messages, TYPSYSTEM must be
ON (See Appendix D, Definitions). All System Status Message have a bell (O7H or CTRL G) preceding the message except
when Messform is ON. If MESSFORM = OFF Line A will be displayed. If MESSFORM = ON Line B will be displayed.
1. A"TOO MANY CHARACTERS FOR COMMAND"BEMO1
This message will be displayed if more than the allocated
number of characters are typed for a command. This is
because some commands are truncated at a length of 8
characters.
2. A"AMBIGUOUS COMMAND"
BEMO2
This is the case of not enough characters being entered
to uniquely identify a command.
3.A"INVALID ARGUMENT"
BEM03
This is displayed when a non valid value is given to a
Command. Example; a value of O cannot be given to
FRACK because the only valid values are 1-255.
Revised: 8 Oct 03APX C-1EST P/N AA104
APPENDIX C
ESTeem MESSAGE TABLES
ESTeem System Status Messages
Listed below are the ESTeem System Status Messages and their definitions. To receive these messages, TYPSYSTEM must be
ON (See APPENDIX D, DEFINITIONS). All System Status Messages have a bell (O7H or CTRL G) preceding the message
except when Messform is ON. If Messform = OFF Line A will be displayed. If Messform = ON Line B will be displayed.
1. A"CONNECTED TO XX"
BSSO1-xx
This message is caused by either receiving a reply
from a Log On Packet, receiving a Log On Packet, or by
typing LINK when connected and in the COMMAND
MODE. XX is the address of the m odem connected to.
2. A"DISCONNECTED FROM XX"
BSSO2-xx
Tells that you have been disconnected from the device
you were originally connected to (xx is unit address).
3. A"LINK DOWN"
BSSO3
7.A"USING FACTORY DEFAULTS"
BSS07
This command states when factory defaults have been
enabled.
8.A"REMOTE PROGRAMMING"
BSS08
This message is displayed when the ESTeem has been
placed in the remote programming mode.
9.A"PHONE MODEM CONNECTED. INFRARED
PORT DISABLED"
BSS09
This message occurs after sending the last retry data
packet and receiving no response from the destination
node. This message usually indicates a hard failure
-i.e. destination node not energized, wrong baud rate,
(not compatible between units) improper
transmit/receive frequency between nodes, etc.
4. A"CURRENTLY NOT CONNECTED!"
BSSO4
The Disconnect was issued while the modem was not
connected to another modem or when LINK is typed in
the COMMAND MODE when you are not connected.
This message is displayed when the modem is configured in
the monitor mode.
5.A"FAILED TO CONNECT!"
BSS05
This message occurs if the modem fails to connect.
6.A"FAILED TO DISCONNECT!"
BSS06
This message is displayed when the ESTeem phone
port has received an in-coming call.
10. A"PHONE MODEM DISCONNECTED.
INFRARED PORT ENABLED"
BSS10
This message is displayed when the ESTeem port has
been disconnected.
This message occurs if the modems are connected and
are unable to disconnect.
Revised: 8 Oct 03APX C-2EST P/N AA104
APPENDIX C
ESTeem MESSAGE TABLES
ESTeem System Error Messages
Listed below are the ESTeem System Error Messages and their definitions. To receive these messages, TYPSYSTEM must be
ON (See APPENDIX D, DEFINITIONS). All System Status Messages have a bell (O7H or CTRL G) preceding the message
except when Messform is ON. If Messform = OFF Line A will be displayed. If Messform = ON Line B will be displayed.
1.A"NOVRAM FAILED"
BSEO1
If this response is received after a save, there is a
hardware problem with the ESTeem's NOVRAM
Circuitry.
2.A"ROM FAILED"
BSEO2
If this response is received after a save, there is a
hardware problem with the ESTeem's ROM Circuitry.
Revised: 8 Oct 03APX C-3EST P/N AA104
Listed below are the software commands and their factoy default setting.
APPENDIX D
SOFTWARE COMMANDS
HELP CONTROL
APPENDRU= 255
CONNECT
CONVERS
DISCONNE
FACTORY
FLASH
HELP
MULTID= OFF
PACKMON= OFF
RADIO= OFF
RESET
ROUTE= 0
RESTORE= 0
SAVE
TRANSPAR= OFF
HELP RS-232
AUTOLF= ON
BLOCK= OFF
COMRATE
DTR_ENAB= OFF
ECHO = ON
MODECONT= OFF
XHFLOW= OFF
XSFLOW= ON
HELP SETUP
ADDRESS= 1
COMMAND= 3
EDIT = ON
MESSFORM = OFF
NETWORK= 37
PACKLENG= 2000
PROMPT= ON
RETRY = 6
SENDPAC= 13
SETCON= 2
TERMCONT = OFF
TERMTIME= 50
TYPERROR= OFF
TYPSYSTE= ON
HELP SYSTEM
COPRIGHT
DISACK= OFF
HOUR
MODEL= 19C
OPTION
POLL= OFF
PROGRAM= 0
SENDDEL= 0
REMPROG= ON
SECURITY= OFF
SENDDEL= 0
S/N= 0
TXSTAT
VERSION= 1.51
HELP PLC
A_BCTRL = OFF
CUTLER= OFF
DNP= OFF
GE_CTRL= OFF
MODCTRL = OFF
OPTO= OFF
PLC_MAST = OFF
SCASERVE = OFF
SQDADD= 0
SQDCTRL = OFF
HELP RADIO
ASQUELCH= 0
DATARATE= 64
CARBSY = 1
DQ= OFF
FRACK = 50
LAT
MODULATE= ON
RANDOM= OFF
RFWAIT= 2
RFCYCLES= 10
RXDATA= 1
RXEND= 1
RXSIGNAL= OFF
SEL/A1= 0
SEL/N1= 0
SEL/N2 = 0
SQUELCH= 0
TXFLAG= 0
TXEND= 0
Revised: 13 Sep 05APX D-1 EST P/N AA104
APPENDIX D
SOFTWARE COMMANDS
Listed below in alphabetical order are the definitions of the ESTeem software commands.
A_BCTRL
This function enables the Allen Bradley controller protocol. For further details reference the EST Engineering Report on Allen
Bradley controller interfacing.
ON:Enabled.
OFF:Disabled.
Factory default = OFF.
ADDress (1-255)
The command defines the ESTeem source address. The default value is whatever address has been stored in nonvolatile
memory. Addresses 1 to 254 are usable for unit addressing. Address 255 is used for GLOBAL.
APPEndru (l#,r#,a1,a2,g)
The APPEndru command appends routes to a connect address that are defined by the ROUTE command.
l # =Location of route number in memory. Address locations 1 to 16.
r # =Appended route number. Route numbers 1 to 16.
a1 = Address of first destination node. Address numbers from 1 to 254.
a2 =Address of last destination node. . Address numbers from 1 to 254.
g=Group feature is enabled by inserting a 1 in this field.
Factory default = 0. APPEndru 0 disables this feature.
Note:This command is used in conjunction with the ROUTE Command.
ASQuelch (0, 255)
This command defines the squelch threshold of the receiver. This command is only used on the Model 192CHP. The ESTeem
will auto adjust this setting.
AUtolf (on/off)
This command enables the auto line feed sent to the terminal after each carriage return.
ON:Enabled.
OFF:Disabled.
Factory default = ON.
BLOck (on/off)
The BLOCK command, when enabled, disables the RS-232C/422/485 communications port from receiving or outputting data.
ON:Enabled.
OFF:Disabled.
Factory default = OFF.
CARbsy (0-255)
This command defines the carrier busy delay in milliseconds. A value of 0 will disable the carrier busy delay. Factory default =
1.
Revised: 13 Sep 05APX D- 2EST P/N AA104
APPENDIX D
SOFTWARE COMMANDS
COMMand (0-255)
This command specifics the value (in decimal) of an ASCII character used to return the ESTeem to COMMAND MODE. If the
COMMAND character is read by the ESTeem when in the CONVERSE MODE, the modem will exit to the COMMAND
MODE. A value of 0 in this command will disable the function. Factory default = $O3 (Hex) or CTRL-C.
COMRate (0-255)
This command defines the RS-232/422/485 configuration when Switch 1 on the RS-232 Setup Switches is engaged. See Chapter
5 for table.
CONNect (r1,r2,r3,da)
This command performs the CONNECT to a destination ESTeem. This function supports a direct connect or a connect through a
maximum of three repeater nodes. The default value is whatever address has been stored by the SETCon COMMAND.
r1 = ESTeem address (1 to 254) of repeater 1.
r2 = ESTeem address (1 to 254) of repeater 2.
r3 = ESTeem address (1 to 254) of repeater 3.
da =Destination address (1 to 254).
CONVers
The execution of this command causes an immediate exit from COMMAND MODE into CONVERSE MODE.
COPright
The execution of this command causes the copyright information to be printed.
CUTler (On/Off)
This command command enables the Cutler Hammer controller protocol. For further information reference Engineering Report
01-003. Factory default = Off.
On: Enabled
Off: Disabled
DArate (0 or 64)
This command sets the RF data rate on the Model 192C/CHP/F/M products. This value is set at the factory and should not be
changed. Factory default = 0.
0 = 19,200 bps
64 = 9,600 bps
DISACK (on/off)
This command when enabled instructs the modem to disable the acknowledgment request on the information packet. This is used
when the designation device will respond with its own acknowledgment. Factory default = OFF.
On: Enabled
Off: Disabled
DISCONnect (1-254)
The disconnect command. The execution of this command immediately initiates a disconnect request with the currently
connected node or in a multi-connect environment only a specific node may be addressed.
Revised: 13 Sep 05APX D- 3EST P/N AA104
APPENDIX D
SOFTWARE COMMANDS
DNP (On/Off)
This command command enables the DNP protocol. For further information reference Engineering Report 21-004. Factory
default = Off.
On: Enabled
Off: Disabled
DTR_enab (on/off)
The DTR enable command. This command, when enabled, allows the ESTeem modem to monitor pin 20 of the RS-232C
connector in regards to the status of an external device connected to it.
ON:Enables monitoring the DTR signal on pin 20 of the RS-232C connector. If DTR is at a space condition, then the
modem is enabled. If DTR is at a mark condition, then the ESTeem modem will be disabled. The normal operation of
this line is for the ESTeem modem to have status on the external device, out-putting to pin 20. This line can act as a
status to the ESTeem when the external device is ready to transmit or receive data.
OFF:Disabled
Factory default = OFF.
Note:If the DTR command is enabled and the line is disabled then the ESTeem will perform a "Disconnect" if connected. The
DTR Command will also activate the Data Carrier Detect (DCD) Line (Pin 8) to toggle High when connected and Low
when disconnected.
ECHO (on/off)
This command enables the ESTeem to echo characters received from the input device back to the input device.
ON:Enabled.
OFF:Disabled.
Factory default = ON.
EDit (on/off)
This command enables the EDIT functions from the CONVERSE Mode.
Factory default = ON.
FActory
The factory default command. The execution of this command causes the ESTeem to restore the command table values from
factory values that are stored permanently in memory. This will allow the user the ability to restore the ESTeem to factory
conditions during testing or set-up.
FLASH
This command places the ESTeem in Flash mode for reprogramming of the operation system.
FRAck (1-255)
This command programs the frame acknowledge delay in milliseconds. This value is used as a minimum time before
decrementing the retry count and retransmitting a packet if the retry count is not zero.
Factory default = 50.
Revised: 13 Sep 05APX D- 4EST P/N AA104
APPENDIX D
SOFTWARE COMMANDS
GE_CTRL
This command enables the General Electric controller protocol. For further information please reference the EST Engineering
Report on General Electric controller interfacing.
ON:Enabled.
OFF:Disabled.
Factory default = OFF.
HElp
HELP switches are:
HELPDisplays this Help menu.
HELP ALLDisplays All commands switches and arguments.
HELP CHANGEDisplays only the commands that are changed from factory default.
HELP CONTROLDisplays Control commands switches and arguments.
HELP PLCDisplays PLC commands switches and arguments.
HELP RADIODisplays Radio commands switches and arguments.
HELP RS-232Displays RS232 commands switches and arguments.
HELP SETUPDisplays Setup commands switches and arguments.
HELP SYSTEMDisplays System commands switches and arguments.
JOHNctrl (on/off)
This function enables the Johnson controller protocol. For further detail Reference the EST Engineering Report on Johnson
controller interfacing.
ON:Enabled.
OFF:Disabled.
Factory default = OFF.
LAT
Latches the selection of the desired serial frequency synthesizer on the Tx/Rx card
Revised: 13 Sep 05APX D- 5EST P/N AA104
APPENDIX D
SOFTWARE COMMANDS
MESSform (on/off)
When enabled all of the system status and error messages will be in a formatted form.
"xx"indicates what error or message (See Error Messages and System Status Messages).
EMxx <CR>[ESTeem Error Messages]
SExx <CR>[System Error Messages]
SSxx <CR>[System Status Messages]
SSxx-xxxx <CR>[System Status Message W/Returned Value]
ON:Enabled.
OFF:Disabled.
Factory default = OFF.
MOdecontr (on/off)
ON: The mode of the ESTeem modem is controlled by pin 19 of the RS-232C connector. A low (0) directs the ESTeem into
the COMMAND mode. A high (1) directs the ESTeem into CONVERSE/TRANSPARENT mode.
OFF:The mode of the ESTeem modem is controlled by ASCII character.
Factory default = OFF
MODEL (xx)
Displays the product model of default firmware that is installed. Model should be the same as product being used. Listed below
are the model codes
19C = ESTeem Model 192C
19F = ESTeem Model 192F
19V = ESTeem Model 192V
MODCTRL
This command enables the Modicon controller protocol. For further detail Reference the EST Engineering Report on Modicon
controller interfacing.
OFF:Disabled.
Factory default = OFF.
MODUlate (on/off)
The radio modulate command. When enabled will transmit a modulated test signal when the RADIO ON command is enabled.
ON:Enabled.
OFF:Disabled.
Factory default = OFF.
MOORE (on/off)
This function enables the Moore products using Hart protocol. For further details reference the EST Engineering Report on
Moore Products interfacing.
ON:Enabled.
OFF:Disabled.
Factory default = OFF.
Revised: 13 Sep 05APX D- 6EST P/N AA104
APPENDIX D
SOFTWARE COMMANDS
MULTID (on/off)
This command when enabled allows the ESTeem User to send data to another ESTeem from the CONVERSE MODE by
specifying the routing address before the data.
ON:Enabled.
OFF:Disabled.
Factory default = OFF.
Example Of Transmitted Data:
[001]DATARoutes data to an ESTeem addressed 1.
[100,200,250,1]DATA Routes data to an ESTeem addressed 1 via ESTeems addressed 100, 200, and 250.
This replaces using the CONNECT command from the COMMAND Mode. Received data packets will have the address of the
ESTeem that sent the data at the beginning of the data packet.
Example Of Received Data:
[004]RECEIVED DATA Data received from an ESTeem addressed 4.
[030,100,244,004]Data received from an ESTeem addressed 4 via ESTeems addressed 30, 100, and 244.
NETwork (0-255)
Network identification code. This is used to program a common code for all modems in the customers network so that another
facility on your frequency using the same addresses will not interfere with your equipment. Factory default = 37.
OPTO (on/off)
This function enables the Opto 22 protocol. For further details reference the EST Engineering Report on Opto 22 interfacing.
ON:Enabled.
OFF:Disabled.
Factory default = OFF.
PACKleng (1-2000)
This command defines the length of the data packet in bytes. Factory default = 2000.
PACKMon (on/off)
Places the ESTeem in the packet monitor mode. Factory default = OFF.
PHone (on/off)
Phone port enable command. The ESTeem will answer an incoming call when enabled.
ON:Enabled.
OFF:Disabled.
Factory default = OFF.
Revised: 13 Sep 05APX D- 7EST P/N AA104
APPENDIX D
SOFTWARE COMMANDS
PLC_MAST (on/off)
The programmable logic controller (PLC) command.
ON:When enabled, the ESTeem modem will identify the desired route from the master PLC message. The ESTeem modem
will only identify the PLC master route if the master command is enabled in the PLC.
OFF:The ESTeem modem will be configured as to interface to a slave PLC.
Factory default = OFF.
POLLed (on/off)
When enabled the ESTeem will only transmit the contents of its internal transmit buffer when it receives an ENQ (hex 5) from a
polling ESTeem. During non polled times the ESTeem transmit buffer will be continuously updated from data being received by
the
RS-232C/422 port. This software feature was developed for interfacing the ESTeem to output devices without flow control that
are to be polled from a master device.
ON:Enabled will transmit the contents of its transmit buffer when a ENQ (hex 5) is received.
OFF:Disabled.
Factory default = OFF.
PROGram (1-254,1-254,1-254,1-254)
This command is used to remote program another ESTeem unit. Example PROG 10 (Unit 10 is the address of the remote unit).
When a connection has been made with the remote ESTeem the RPG: prompt will appear. The RPG: prompt is the command
prompt of the remote modem.
Note:See REMPROG Command.
PROMpt (on/off)
The prompt enable command.
ON:The prompt responses are enabled. These are the prompts for Converse or Trans Mode that are normally output from
the RS-232C serial port by the ESTeem.
OFF:Disabled.
Factory default = ON.
RADio (on/off)
The radio transmitter enable command. The ESTeem radio transmitter will cycle on and off when enabled for tuning and antenna
testing procedures.
ON:Enabled.
OFF:Disabled.
Factory default = OFF.
RANdom (on/off)
The RANDOM command when enabled will generate a simulated random data output when the RADIO ON command is
enabled
ON:Enabled.
OFF:Disabled.
Factory default = OFF.
Revised: 13 Sep 05APX D- 8EST P/N AA104
APPENDIX D
SOFTWARE COMMANDS
REMprog (on/off)
This command will disable the ESTeem from being remotely programmed by any another ESTeem.
ON:Enabled.
OFF:Disabled.
Factory default = ON.
RESet
The software reset command for the ESTeem. The execution of this command resets the internal electronics in the ESTeem.
RESTore
The restore command. The execution of this command restores the ESTeem command variables and switches configurations
stored in nonvolatile memory.
RETry (1-255)
The retry command number. This is the number specifying the number of retries, retransmission of frames, that are not
acknowledged. Frames are retransmitted RETRY times before operation is aborted. Factory default = 6.
RFcycles
This command defines the number of cycles the ESTeem will transmit when programmed with the RADIO COMMAND.
Factory default = 10.
RFWait (1-255)
This command command defines the time in milliseconds the receiver waits afer a carrier detect before starting the acquire
sequence. This value is optimized at the factory for the specific product and should not be changed.
ROUTe (l#,r1,r2,r3,)
The ROUTE sets up the route table in the ESTeem.
l #=User defined route number. Route numbers 1 to 16 may be used.
r1= Address of first repeater. Address numbers from 1 to 254 may be used.
r2= Address of second repeater. Address numbers from 1 to 254 may be used.
r3= Address of third repeater. Address numbers from 1 to 254 may be used.
Note:See APPENDRU Command.
Factory default = 0.
RXData (1-255)
This command defines the time (milliseconds) the receiver waits after a carrier detect before starting the receive sequence. This
value is optimized at the factory and should not be changed.
Factory default = 1.
Revised: 13 Sep 05APX D- 9EST P/N AA104
APPENDIX D
SOFTWARE COMMANDS
RXEnd (1-255)
This command defines the time (milliseconds) to wait after the last character is received before reinitializing the receiver.
Factory default = 1.
RXSIGNAL (on/off)
This command enables the signal to noise ratio meter output. Output level varies from 0 to 248 (248 being the highest reading).
ON:Enabled.
OFF:Disabled.
Factory default = OFF.
SAve
The save command. The execution of this command stores the current command values and switches.
Note:Please wait approximately two seconds after executing the SAVE command before turning off power to the ESTeem.
SECURITY (off or 1- 100000)
The security command disables programming the ESTeem.
1 to 100000 This feature is enabled when you enter a number from 1 to 100000. When enabled the ESTeem will return a
Security ON message. To disable security enter SECURity xxxxxx.
xxxxxx = your predefined security number. When disabled the ESTeem will return a Security Off message.
OFFSecurity disabled.
Factory default = OFF.
SENDDel (0 to 65535)
This command sets the time to wait before sending back the contents of the transmit buffer when a global ENQ is received and
POLL Mode is enabled. This allows for several polled ESTeems to respond back at different times keeping the transmissions
from colliding. Reference Polled Command.
SENDPACK (0-255)
Send packet (SENDPACK) command. The value specifies an ASCII character used to signal when to send the packet. If set to a
value of 255 the command is disabled. The factory default value is 13 (Return).
SEL/A1 (1-255)
The SEL/A1 command sets the transceiver for a specific frequency.
SEL/N1 (1-56635)
The SEL/A1 command sets the transceiver for a specific frequency.
SEL/N2 (1-999)
The SEL/N2 command sets the transceiver for a specific frequency.
SETCon (r1,r2,r3,da)
This command defines the destination address for the ESTeem to perform a connect using the Auto Connect feature. This
function supports a direct connect or a connect through a maximum of three repeaters.
r1 = ESTeem address (1 to 254) of repeater 1.
r2 = ESTeem address (1 to 254) of repeater 2.
r3 = ESTeem address (1 to 254) of repeater 3.
da = Destination address (1 to 254).
Revised: 13 Sep 05APX D- 10EST P/N AA104
APPENDIX D
SOFTWARE COMMANDS
S/N
Serial Number command. When executed from the Command Model will output the ESTeem serial number of the unit that is
defined at the time of manufacturer.
SQDCTRL (on/off)
This function enables the Square D controller protocol. For further detail Reference the EST Engineering Report on Square D
controller interfacing.
Factory default = OFF.
SQDADD (1-254)
This function is used with the SQDCTRL command to control the address fence when using SQ-D Network Interface Modules.
For further details reference the EST Engineering Report on the SQ-D controller.
Factory default = 0.
SQUELCH (0-3)
This command defines the squelch threshold of the receiver. Listed below are the settings:
0=-101 dBm 2µV
1=- 93 dBm 5µV
2=- 87 dBm10µV
3=- 70 dBm70µV
Factory default = 0.
TERMCont (on/off)
The RS-232C/422/485 receive termination timer.
ON:If there are characters in the RS-232 buffer and the modem is in Converse Mode, the termination timer starts from the
time the last receive character is updated in the buffer. If the termination time expires before another character is
received, the characters are transmitted.
OFF:Disabled
Factory default = OFF.
TERMTime (10-65535)
The RS-232C/422/485 receive termination timer value. This value can be 10 to 65535 milliseconds. This value is enabled by
TERMCONT. Factory default = 5O.
TRANSPAR (on/off)
The transparent mode command. This mode allows the ESTeem link to be completely transparent to the communicating
RS-232/422/485 devices. Reference Chapter 2.
ON:Enabled.
OFF:Disabled.
Factory default = OFF.
TXSTAT
This command outputs the total number of rf transmissions vs. the total number of retries. After output is completed, the counter
is zeroed.
Revised: 13 Sep 05APX D- 11EST P/N AA104
SOFTWARE COMMANDS
TYPerr (on/off)
This command enables the Communication Error Messages.
ON:Enabled.
OFF:Disabled.
Factory default = OFF.
TYPSyste (on/off)
This command enables the System and Error Message Commands.
ON:Enabled.
OFF:Disabled.
Factory default = ON.
VERSION
This command will display the current software version being used by the ESTeem.
XHflow (on/off)
This command enables hardware flow control.
APPENDIX D
ON:Enabled.
OFF:Disabled.
Factory default = OFF.
XSflow (on/off)
This command enables software flow control.
ON:Enabled.
OFF:Disabled.
Factory default = ON.
Revised: 13 Sep 05APX D- 12EST P/N AA104