Electric Dryer
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
RECESSED AREA AND CLOSET INSTALLATION
EXHAUST VENTING
TEDS680E
TEDS780J
TEDX640E
TEDX640J
Electrical: A four-wire or three-wire, single phase,
120/240-volt, 60-Hz, AC-only, electrical supply is
required on a separate 30-ampere circuit, fused on
both sides of the line. Use 10 gauge solid copper
wire. A time-delay fuse or circuit breaker is
recommended.
Exhaust venting: Exhaust your dryer to the
outside. Four-inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do Not
use plastic or metal foil vent. Exhaust outlet hood
must be at least 12 inches from the ground or any
object that may be in the path of the exhaust.
Closet confined area
4"
4"
Preferred
Number of Rigid Flexible
90° elbows (fully extended)
When you have a 4" hood
Maximum length of 4"
diameter metal vent
0
1
2
3
4
64 ft.
54 ft.
44 ft.
35 ft.
27 ft.
36 ft.
31 ft.
27 ft.
25 ft.
23 ft.
Acceptable
Number of Rigid Flexible
90° elbows (fully extended)
When you have a 2-1/2" hood
Maximum length of 4"
diameter metal vent
0
1
2
3
4
58 ft.
48 ft.
38 ft.
29 ft.
21 ft.
28 ft.
23 ft.
19 ft.
17 ft.
15 ft.
2-1/2"
Select the route that will provide the straightest and most direct path
outdoors. Plan the installation to use the fewest number of elbows and
turns. Avoid making 90° turns.
When using elbows or making turns, allow as much room as possible.
Bend flexible metal vent gradually to avoid kinking.
Determine vent length
1. See the exhaust vent length chart that matches your type hood for the
maximum vent lengths you can use.
Do not use vent runs longer than specified in exhaust vent length charts.
2. Determine the number of elbows you will need.
3. In the column listing the type of metal vent you are using (rigid or
flexible), find the maximum length of metal vent on the same line as the
number of elbows.
The maximum length using a 2" x 6" rectangular vent with 2 elbows and
a 2-1/2" exhaust hood is 8 ft.
3"
3"
48 sq. in.
**
24 sq. in.**
14"
max.
front view
1"
closet
door
** Minimum top and bottom air openings for closet door.
*** External exhaust elbow requires additional space.
0" *
0" *
front view
18"
If a closet door is installed: The minimum unobstructed air
openings are required. Louvered doors with equivalent air
openings are acceptable.
*Wall, door and floor molding may require
additional spacing.
side view
Recessed
Closet
Back
5"/0"
5"/4"
Sides
1"/0"
1"/0"
Top
18"/18"
18"/18"
Front
—
1"/1"
Recommended/Minimum
Recessed
area
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 3397618
01-09-03
4"***
*from floor with dryer
feet extended 1 inch
29"
28" max.
14-1/2"
dryer exhaust
vent
power supply
cord/cable
opening
6"*
42-3/8"*
terminal
block cover
DOOR CLEARANCE DIMENSIONS
Large side-swing
door (reversible)
17-3/4"
22-3/4"
22-3/4"
7"
Extra-large hamper door
Small side-swing door
15-1/4"
15-1/4"
15-1/4"
13-3/4"
13-3/4"
25-5/8"
8-1/4"
8-3/4"
22-3/4"
22-3/4"
19-1/8"
Super-large
side-swing door (reversible)
3-7/8"