Estate TEDX340R, TEDX540R, TEDX640P, TEDS840P, TEDS740P User Manual

...
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
RECESSED AREA AND CLOSET INSTALLATION
EXHAUST VENTING
EED4100S EED4300S EED4400S TEDS740P
TEDS840P TEDX340R TEDX540R TEDX640P
Electrical: A four-wire or three-wire, single phase, 120/240-volt, 60 Hz, AC-only, electrical supply (or 120/208-volt electrical supply, if specified on the serial/rating plate) is required on a separate 30 amp circuit, fused on both sides of the line. Use 10 gauge solid copper wire. A time-delay fuse or circuit breaker is recommended.
Exhaust venting: Exhaust your dryer to the outside. Four-inch diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do not use plastic or metal foil vent. Exhaust outlet hood must be at least 12 inches from the ground or any object that may be in the path of the exhaust.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. 8577187
08-10-06
A. Small opening side-swing door B. Large opening side-swing door C. Wide opening side-swing door D. Wide opening hamper door
43³⁄₈"
(110cm)
*26" (66cm)
29"
(73.66cm)
A
15¼"
(38.74cm)
43³⁄₈"
(110cm)
*27¾"
(70.5cm)
29"
(73.66cm)
B
22¾"
(57.8cm)
43³⁄₈"
(110cm)
13¾"
(34.9cm)
*27¾"
(70.5cm)
29"
(73.66cm)
D
43³⁄₈"
(110cm)
*27¾"
(70.5cm)
29"
(73.66cm)
C
22¾"
(57.8cm)
For closet installation with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air openings are acceptable.
Electric Dryer
* Most installations require a
minimum 5¹⁄₂" (14 cm) clearance behind the dryer for the exhaust vent with elbow.
Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. Avoid making 90° turns.
Do not use vent runs longer than specified in vent length chart. Determine the number of elbows you will need.
A. Louvered hood style
B. Box hood style
4" (10.2 cm)
4" (10.2 cm)
A
B
4"
(10.2 cm)
2.5"
(6.4 cm)
Recommended hood styles
Angled hood style is
acceptable.
Type of vent
Flexible metal
Flexible metal
Flexible metal
Flexible metal
Flexible metal
Number of 90° turns or elbows
0Rigid metal
1Rigid metal
2Rigid metal
3Rigid metal
4Rigid metal
NOTE:
Side and bottom exhaust installations have a 90° turn inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart.
Box or Louvered hoods
64 ft (20 m) 36 ft (11 m)
54 ft (16.5 m) 31 ft (9.4 m)
44 ft (13.4 m) 27 ft (8.2 m)
35 ft (10.7 m) 25 ft (7.6 m)
27 ft (8.2 m) 23 ft (7 m)
Angled hoods
58 ft (17.7 m) 28 ft (8.5 m)
48 ft (14.6 m) 23 ft (7 m)
38 ft (11.6 m) 19 ft (5.8 m)
29 ft (8.8 m) 17 ft (5.2 m)
21 ft (6.4 m) 15 ft (4.6 m)
18" (45.7 cm)
0"* (0 cm)
29" (73.66 cm)
0"* (0 cm)
A
*Additional spacing recommended
0"* (0 cm)
14" max. (35.6cm)
5½"
27¾"
(14 cm)
(70.5 cm)
B
2
48 in.
2
(310 cm )
2
24 in.
2
(155 cm )
C
3" (7.6 cm)
3" (7.6 cm)
A. Recessed area B. Side view - closet or confined area C. Closet door with vents