Estate ETW4400W User Manual

27"
(
686 mm)
42"
(
1067 mm)
25
1
/2"
Top Load Washer
3"
(76 mm)
3"
(76 mm)
24 in.
2
(155 cm2)
48 in.
2
(310 cm2)
19"
(483 mm)
1"
(25 mm)
0"
(0 mm)
4"
(102 mm)
1
4" max.
(356 mm)
PRODUCT MODEL NUMBERS
VERALL DIMENSIONS
O
ETW4100S, ETW4400V, ETW4400W
Electrical: A 120 volt, 60 Hz., AC only, 15- or 20-amp, fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is recommended that a separate circuit serving only this appliance be provided.
RECESSED AREA OR CLOSET INSTALLATION
For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air ventilation openings are acceptable.
DRAIN SYSTEM OPTIONS
Wall standpipe drain system
Floor drain system
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Minimum diameter for a wall or floor standpipe drain: 2"(51 mm). Minimum carry-away capacity: 17 gal (64L) per minute. Top of standpipe must be at least 39
"
(991 mm) high; install no higher than 96"(2.4 m) from bottom of washer. A sump pump system is required for higher installations.
Laundry tub drain system
Minimum capacity: 20 gal (76 L). Top of laundry tub must be at least
"
39
(991 mm) above floor; install no higher than 96"(2.4 m) from
bottom of washer.
Floor drain system
Floor drain systems require a Siphon Break Kit (Part No. 280129) and additional drain hose (Part No. 3357090). Minimum siphon break:
"
(711 mm) from bottom of washer. Additional hoses might be needed.
28
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10200890-D-ES
06/2009