Estate EED4400W User Manual

29" (73.7 cm) Electric Dryer
22
3
/4"
(578 mm)
43
3
/8"
(1102 mm)
*27
3
/4"
(705 mm)
29
"
(737 mm)
29"
(737 mm)
*26
"
(660 mm)
43
3
/8"
(1102 mm)
15
1
/4"
(387 mm)
43
3
/8"
(
1102 mm)
*27
3
/4"
(705 mm)
29"
(737 mm)
22
3
/4"
(578 mm)
43
3
/8"
(1102 mm)
*27
3
/4"
(705 mm)
29
"
(737 mm)
13
3
/4"
(349 mm)
A
B
C
D
A. Recessed area B. Side view - closet or confined area C. Closet door with vents
A
B
C
18"*
(457 mm)
1"
(25 mm)
29"
(737 mm)
1"
(25mm)
1"*
(25mm)
14" max.* (356
mm)
27¾"
(705 mm)
5"*
(127 mm)
48 in.
(310 cm )
2
*
2
24 in.
(150 cm )
2
*
2
3"*
(76 mm)
3"*
(76 mm)
Number of 90 turns or elbows
Type of vent
Box or Louvered hoods
Angled hoods
0
Rigid metal
64 ft (20 m)
58 ft (17.7 m)
1
54 ft (16.5 m)
48 ft (14.6 m)
2
44 ft (13.4 m)
38 ft (11.6 m)
3
35 ft (10.7 m)
29 ft (8.8 m)
4
27 ft (8.2 m)
21 ft (6.4 m)
Rigid metal
Rigid metal
Rigid metal
Rigid metal
o
Louvered style
4"
(102 mm)
4
"
(102 mm)
Box hood style
4"
(102 mm)
Angled style
21/2"
(64 mm)
RODUCT MODEL NUMBERS
P
ED4400W
E
Electrical: To supply the required three- or four­wire, single-phase, 120/240-volt, 60-Hz, AC-only electrical supply (or three- or four-wire, 120/208-volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit,
used on both sides of the line. A time-delay fuse
f or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm) diameter heavy metal exhaust vent and clamps must be used. DURASAFE™ venting products are recommended. For best drying performance, rigid metal vents are recommended. Flexible metal vents are acceptable only if accessible for cleaning. Do NOT use plastic or metal foil vent. Exhaust outlet hood must be at least 12" (304 mm) from the ground or any object that may be in the path of the exhaust.
RODUCT DIMENSIONS
P
A. Small Opening
Side-Swing Door
B. Large Opening
Side-Swing Door
C. Wide Opening
Side-Swing Door
D. Wide Opening
Hamper Door
*Most installations require a minimum 5" (127 mm) clearance behind the dryer for exhaust
vent with elbow.
EXHAUST VENTING
Vent System Chart NOTE: Side and bottom exhaust installations have
a 90° turn inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
RECESSED AREA AND CLOSET INSTALLATION
For closet installation with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air openings are acceptable.
1. Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. When using elbows or making turns, allow as much room as possible. Bend vent gradually to avoid kinking. Use the fewest 90° turns possible.
2. Determine vent length.
The maximum length of the exhaust system depends upon:
• The type of vent (rigid metal or flexible metal).
• The number of elbows used.
• Type of hood.
See the exhaust vent length chart that matches your hood type for the maximum vent lengths you can use.
3. Determine the number of elbows you will need.
IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.