Estate EED4400V, EED4300V User Manual

Electric Dryer
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
RECESSED AREA AND CLOSET INSTALLATION
EXHAUST VENTING
EED4300V EED4400V
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10150612
04-18-08
43³⁄₈"
(
110cm)
*26" (66cm)
29"
(73.66cm)
A
15¹⁄₄"
(38.74cm)
43³⁄₈"
(110cm)
*27³⁄₄"
(70.5cm)
29"
(73.66cm)
B
22³⁄₄"
(57.8cm)
43³⁄₈"
(110cm)
13³⁄₄"
(34.9cm
)
*27³⁄₄"
(70.5cm)
29"
(73.66cm)
D
43
³⁄₈
"
(
110cm)
*27³⁄₄"
(70.5cm)
29"
(73.66cm)
C
22³⁄₄"
(57.8cm)
For closet installation with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air openings are acceptable.
1. Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. When using elbows or making turns, allow as much room as possible. Bend vent gradually to avoid kinking. Avoid 90° turns.
2. Determine vent length.
The maximum length of the exhaust system depends upon:
• The type of vent (rigid metal or flexible metal).
• The number of elbows used.
• Type of hood.
See the exhaust vent length chart that matches your hood type for the maximum vent lengths you can use.
3. Determine the number of elbows you will need.
IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart. In the column listing the type of metal vent you are using (rigid metal or flexible metal),
find the maximum length of metal vent on the same line as the number of elbows.
Electrical: A four-wire or three-wire, single phase, 120-volt, 60 Hz, AC-only, electrical supply is required on a separate 15 or 20 amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended.
Exhaust venting: Exhaust your dryer to the outside. Four-inch diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do Not use plastic or metal foil vent. Exhaust outlet hood must be at least 12 inches from the ground or any object that may be in the path of the exhaust.
A. Small Opening
Side-Swing Door
B. Large Opening
Side-Swing Door
C. Wide Opening
Side-Swing Door
D. Wide Opening
Hamper Door
*Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for exhaust
vent with elbow.
4"
Box or
Louvered
hoods
(10.2 cm)
Angled
58 ft (17.7 m) 28 ft (8.5 m)
48 ft (14.6 m) 23 ft (7 m)
38 ft (11.6 m) 19 ft (5.8 m)
29 ft (8.8 m) 17 ft (5.2 m)
21 ft (6.4 m) 15 ft (4.6 m)
Angled style
hoods
Box hood style
4" (10.2 cm)
4" (10.2 cm)
Louvered style
vent
64 ft (20 m) 36 ft (11 m)
54 ft (16.5 m) 31 ft (9.4 m)
44 ft (13.4 m) 27 ft (8.2 m)
35 ft (10.7 m) 25 ft (7.6 m)
27 ft (8.2 m) 23 ft (7 m)
Vent Length Chart
Number of
90° turn s
or elbows
0 Rigid metal
1 Rigid metal
2 Rigid metal
3 Rigid metal
4 Rigid metal
Type of
Flexible metal
Flexible metal
Flexible metal
Flexible metal
Flexible metal
18" (45.7 cm)
14" max. (35.6
cm)
48 in. (310 cm )
2.5"
(6.4 cm)
1" (2.5 cm)
29" (73.66 cm)
1"
1" (2.5 cm)
27³⁄₄" (70.5 cm)
B
(2.5 cm)
A
A. Recessed area B. Side view - closet or confined area C. Closet door with vents
5¹⁄₂" (14 cm)
24 in. (155 cm )
3"
2
2
2
2
(7.6 cm)
3" (7.6 cm)