Electric Dryer
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
RECESSED AREA AND CLOSET INSTALLATION
EXHAUST VENTING
EED4300V
EED4400V
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10150612
04-18-08
110cm)
*26"
(66cm)
29"
(73.66cm)
A
15¹⁄₄"
(38.74cm)
43³⁄₈"
(110cm)
*27³⁄₄"
(70.5cm)
29"
(73.66cm)
B
22³⁄₄"
(57.8cm)
43³⁄₈"
(110cm)
13³⁄₄"
(34.9cm
*27³⁄₄"
(70.5cm)
29"
(73.66cm)
D
43
³⁄₈
"
110cm)
*27³⁄₄"
(70.5cm)
29"
(73.66cm)
C
22³⁄₄"
(57.8cm)
For closet installation
with a door, minimum
ventilation openings in
the top and bottom of
the door are required.
Louvered doors with
equivalent air openings
are acceptable.
1. Select the route that will provide the straightest and most direct path outdoors. Plan
the installation to use the fewest number of elbows and turns. When using elbows or
making turns, allow as much room as possible. Bend vent gradually to avoid kinking.
Avoid 90° turns.
2. Determine vent length.
The maximum length of the exhaust system depends upon:
• The type of vent (rigid metal or flexible metal).
• The number of elbows used.
• Type of hood.
See the exhaust vent length chart that matches your hood type for the maximum vent
lengths you can use.
3. Determine the number of elbows you will need.
IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart.
In the column listing the type of metal vent you are using (rigid metal or flexible metal),
find the maximum length of metal vent on the same line as the number of elbows.
Electrical: A four-wire or three-wire, single
phase, 120-volt, 60 Hz, AC-only, electrical supply
is required on a separate 15 or 20 amp circuit,
fused on both sides of the line. A time-delay fuse
or circuit breaker is recommended.
Exhaust venting: Exhaust your dryer to the
outside. Four-inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do Not
use plastic or metal foil vent. Exhaust outlet hood
must be at least 12 inches from the ground or any
object that may be in the path of the exhaust.
A. Small Opening
Side-Swing Door
B. Large Opening
Side-Swing Door
C. Wide Opening
Side-Swing Door
D. Wide Opening
Hamper Door
*Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for exhaust
vent with elbow.
4"
Box or
Louvered
hoods
(10.2 cm)
Angled
58 ft (17.7 m)
28 ft (8.5 m)
48 ft (14.6 m)
23 ft (7 m)
38 ft (11.6 m)
19 ft (5.8 m)
29 ft (8.8 m)
17 ft (5.2 m)
21 ft (6.4 m)
15 ft (4.6 m)
Angled style
hoods
Box hood style
4"
(10.2 cm)
4"
(10.2 cm)
Louvered style
vent
64 ft (20 m)
36 ft (11 m)
54 ft (16.5 m)
31 ft (9.4 m)
44 ft (13.4 m)
27 ft (8.2 m)
35 ft (10.7 m)
25 ft (7.6 m)
27 ft (8.2 m)
23 ft (7 m)
Vent Length Chart
Number of
90° turn s
or elbows
0 Rigid metal
1 Rigid metal
2 Rigid metal
3 Rigid metal
4 Rigid metal
Type of
Flexible metal
Flexible metal
Flexible metal
Flexible metal
Flexible metal
18"
(45.7 cm)
14" max.
(35.6
cm)
48 in.
(310 cm )
2.5"
(6.4 cm)
1"
(2.5 cm)
29"
(73.66 cm)
1"
1"
(2.5 cm)
27³⁄₄"
(70.5 cm)
B
(2.5 cm)
A
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
5¹⁄₂"
(14 cm)
24 in.
(155 cm )
3"
2
2
2
2
(7.6 cm)
3"
(7.6 cm)
C