Important Safeguards
READ BEFORE USING YOUR HUMIDIFIER
1) This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit into a polarized 120-volt AC, 15-amp outlet, only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature. If an extension cord must be used, it should also accept the wide blade plug and meet this electrical rating.
2) Do not place the cord under rugs, in traffic areas, or near heat sources.
3) Do not use the humidifier if the cord is damaged.
4) Always unplug the power cord before cleaning, servicing or when the unit is not in use.
5) Do not place the humidifier near loose drapes, combustible materials, or heat-producing objects.
6) This humidifier is UL approved with Bemis by Essick Air brand evaporative wicks in place. To maintain your UL rating, see your service center for all repairs. Use only Bemis by Essick Air brand replacement wicks and chemicals. To order parts, wicks and chemicals call 1- 800-547-3888.
7) Regular cleaning is recommended. Refer to CARE & MAINTENANCE
section in this manual
Introduction
Your Bemis by Essick Air evaporative humidifier adds invisible moisture to your home by moving dry inlet air through a saturated wick. As air moves through the wick, the water evaporates into the air, leaving behind any white dust, minerals or dissolved and suspended solids. Because the water is evaporated, there is no messy mist or spray and no white dust, just clean and invisible moist air.
As the evaporative wick traps accumulated minerals from the water, its ability to absorb and evaporate water decreases. We recommend chang­ing the wick at least once a year the end of the humidifying season and starting with a new one at the beginning of the next humidifying season. In hard water areas, more frequent replacement may be necessary to maintain your humidifier's efficiency.
, preferably disposing of the used one at
CAUTION- We recommend using Bemis by Essick Air Bacteria Treatment whenever you refill the reservoir to eliminate bacteria growth. Follow the directions to deter­mine the proper amount to be added to the 1 gallon reservoir.
The wick does not r intended for use in Rotobelt or Water Wheel type humidifiers.
Locate your humidifier on an inside wall, near an electrical outlet. The humidifier should be at least 4" away from the wall for best results. Do not position the unit directly in front of a hot air duct or radiator. We suggest placing the unit on a table or on a bookshelf.
equire the use of chelating agent type water treatments that are
Assembly & Operation
1) Unpack humidifier from carton.
2) Lift off the “cover/chassis” unit from the cabinet. Remove any packaging material from the inside of the cabinet. The evaporative wick (only one) should remain in place, positioned within the two pair of locating ribs inside of the cabinet. (See illustration.)
3) Place the humidifier “cabinet” with evaporative wick at the location where the product will be operated. Fill the “cabinet” reservoir with cool, fresh, preferably unsoftened water to the top of the rear handle shelf. If only softened water is available, it can be used, however you will notice a build up of minerals on the evaporative wick much sooner. A fill level is indicated. Reservoir capacity is one gallon. Do not overfill. If you carry the filled cabinet, tip the evaporative wick side up slightly to avoid spillage.
DO NOT POUR WATER INTO THE TOP GRILLE ONTO THE FAN MOTOR. ELECTRICAL COMPONENTS MUST BE KEPT DRY.
4) In the course of daily operation, we recommend emptying any remaining water in the reservoir, rinsing the humidifier reservoir, and wiping it clean prior to adding fresh water.
5) Place the cover/chassis unit onto the cabinet. Align the cord exit with the slot in the rear of the cabinet. The cover should fit snug over the edges of the bottom.
6) We recommend using Bemis by Essick Air Bacteria Treatment whenever you refill
the humidifier reservoir to eliminate bacterial growth. Add bacteriostat according to the instructions on the bottle.
7) Plug cord into wall receptacle.
8) Turn humidifier on.
Controls
9) Model 926 000 is equipped with a two speed fan control switch. Use the low
setting for quiet operation and the high speed for maximum output.
Care and Maintenance
IMPORTANT: We recommend cleaning your humidifier once a week. Follow instructions.
Humidifiers provide comfort by adding moisture to dry, heated indoor air. To get the most benefit from the humidifier and avoid product misuse, fol­low all instructions carefully, specifically the operation, care and mainte­nance guidelines. Please note this is an electrical appliance and requires careful attention when in use.
In addition, if you do not follow the recommended care and maintenance guidelines, microorganisms may be able to grow in the water within the humidifier's reservoir.
Caution: Disconnect power before cleaning or servicing unit.
1) Turn unit off.
2) Unplug electrical cord from wall outlet.
3) Lift off motor and fan assembly (top portion of humidifier).
REMOVING SCALE
4) Carefully lift wick from cabinet, allowing any water to drain from wick into cabinet.
5) Empty cabinet into sink. Remove any remaining water from cabinet with a sponge. Fill reservoir with one 8 oz cup of undiluted white vinegar. Let solution stay 20 minutes.
Clean all interior surfaces with a soft brush. Dampen a soft cloth with undiluted white vinegar and wipe out reservoir to remove scale.
6) Rinse cabinet thoroughly with fresh water to remove scale & cleaning solution before disinfecting.
DISINFECTING RESERVOIR
EVAPORATIVE WICK
7) Fill reservoir with mixture of one teaspoon chlorine bleach in one gallon water. Let solution stay 20 minutes, swishing every few minutes. Wet all surfaces.
8) Empty reservoir after 20 minutes. Rinse with water until bleach smell is gone. Dry with clean cloth or paper towel.
9) Replace wick in cabinet by sliding the wick into position between locating ribs in sides of cabinet.
10) Replace motor and fan assembly ensuring that it seats correctly on the front and back edge of the cabinet and that the cord is not caught on the edge of the unit.
11) Plug cord into wall outlet. Turn unit on.
12) We recommend replacing the wick at least once a season more often in hard water areas. When it appears excessively clogged with mineral deposits, discard it and restore your humidifier's efficiency with a new wick. Bemis by Essick Air evaporative wick number 1044 fits the 900 Series tabletop humidifiers. For replacement wicks call 800-547-3888. Only Bemis by Essick Air evaporative wicks guarantee the out-put of your humidifier other than Bemis by Essick Air will void your warranty and may reduce the efficiency and output of your humidifier.
. Use of wicks
Summer Storage
1) Clean unit as outlined in Care & Maintenance section.
2) Discard used wick. (install a new Bemis by Essick Air wick at the beginning of the next sea­son. Only Bemis by Essick Air wicks guarantee the output of your humidifier.)
3) Allow unit to dry thoroughly before storage. Do not store with water inside unit.
4) Do not store unit in attic or other high-temperature area.
5) Clean humidifier and install new wick before next season begins.
6) A convenient order form for wicks and accessories is found in the back of this manual.
Accessories
Evaporative Wick
Model 1044. Each 900 Series portable humidifier requires one evaporative wick. The wick continuously wicks up moisture as it traps mineral deposits. Only Bemis by Essick Air wicks guarantee the rated performance from your Bemis by Essick Air Humidifier.
Bacteria Treatment
No. 1970-32 oz. Bacteria Treatment controls bacteria growth in humidifiers. Helps eliminate unpleasant odors.
Humidifier Descaler/Cleaner
No. 1961-32 oz. Descaler/Cleaner Bemis by Essick Air Humidifier Descaler
will clean and prepare your humidifier for efficient operation by removing any lime scale build-up or sediment.
Tabletop Humidifiers
No. H7000
Dust Cover for
700 Series
$4.99
$7.49
No. 1040
Twin Pack Wick for
$12.99
Bacteria Treatment, 32 oz.
No. 1044
900 Series
$5.49
No. 1970
$5.99
Replacement Wick Filter for
Summer Protective
No. SGL1040
Single Pack Wick for
300, 500, & 700 Series
Tabletop Humidifiers
300, 500, & 700 Series
Tabletop Humidifiers
• Helps Eliminate Bacteria & Algae Build-up
• Strongly Recommended for Bemis Humidifiers & All Other Evaporative Humidifiers
No. 1052SGL Air Cleaner for 700 Series Tabletop Humidifiers $5.99
No. 1050 Air Cleaner Filter for 500 Series Tabletop Humidifiers $7.99
No. 1990 Digital Hygrometer/Comfort Sensor $25.99
• Digitally monitors temperature & humidity
No. 1053 Twin Pack Air Cleaner for 300 Series Tabletop Humidifiers $12.99
No. 1961 Humidifier Cleaner, 32 oz. $3.99
• Helps Remove Lime Scale
• Aides in Cleaning Your Humidifier
HOME COMFORT DIVISION
ONE-YEAR LIMITED WARRANTY
The Bemis by Essick Air humidifier warranty covers defects in materials and workman­ship for a period of one year from date of retail purchase. This warranty applies only to the original purchaser of the product.
Within the first 12 months from date of purchase, Essick Air will repair or replace, at its discretion, any defective part of the humidifier covered by this warranty.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state or province to province.
This warranty does not cover damage resulting from misuse or abuse of the humidifier, accidents or alterations to the product, commercial use or damage during ship­ment. Misuse includes malfunctions caused by negligence in cleaning or parts fouled with mineral deposits due to hard-water conditions. Alterations to the product include the sub­stitution of non-Bemis by Essick Air brand components including, but not limited to, wicks.
If service becomes necessary, take or send the product to any Bemis by Essick Air service center.
Essick Air Products, Inc.
5800 Murray Street
Little Rock, AR 72209
501.562.1094
LEER Y CONSERVAR ESTAS INSTRUCCIONES
L
U
®
C
L
U
®
Humidificador Vaporizador
MANUAL
CUIDADO
Y USO
POR EL
PROPIETARIO
Impreso en EE.UU.
Modelo:
916 600 Color de dos Tonos.
Una Velocidad. Humidificador para Mesa
926 000 Humidificador de Dos
Velocidades para Mesa
PROTEJA EL MEDIO AMBIENTE
RECICLE LOS MATERIALES APROPIADOS
Patentes 5,037,583; 5,110,511; 5,133,904
Otras patentes pendientes
Para ordenar repuestos y accesorios llamar al 1-800 547-3888
Loading...
+ 22 hidden pages