Essick Air 736200, 726000, 726400, 726 User Manual

READ AND SAVE THESE INSTRUCTIONS
EVAPORATIVE
HUMIDIFIER
OWNERS CARE & USE
5800 Murray St.
Little Rock, AR 72209
1-800-547-3888
MANUAL
726 000 White/Teal
2- Speed with removable water bottle
726 400 Oak Burl
2- Speed with removable water bottle
736 200 Granite/Blue
3-Speed with removable water bottle, Automatic Humidistat
RECYCLE APPROPRIATE MATERIALS
Patents: 5,037,583; 5,110,511; 5,133,904
To order parts and accessories call 1-800-547-3888
MODELS:
SAVE THE ENVIRONMENT
Other Patents Pending
French and Spanish Instructions included.
Se incluyen instrucciones En Español y Francés.
Directives en Français et en espagnol compris
726 Series
1B71483 4/06
IMPORTANT SAFEGUARDS
READ BEFORE USING YOUR HUMIDIFIER
1) This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit into a polarized 120­volt AC, 15 amp outlet, and only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature. If an extension cord must be used, it should also accept the wide blade plug and meet this electrical rating.
2) Do not place the cord under rugs, near loose drapes, in tr affic areas, nor near heat sources or combustible materials.
3) Do not use the humidifier if the cord is damaged.
4) Always unplug the power cord before filling, cleaning, servicing, or when the unit is not in use.
5) This humidifier is UL listed with Essick Air brand evaporative wicks in place. To maintain your UL rating, see your service center for all repairs.
6) Regular cleaning is recommended. Refer to the CARE & MAINTENANCE section in the manual.
INTRODUCTION
Your Essick Air evaporative humidifier adds invisible moisture to your home by moving dry inlet air through a saturated wick. As air moves through the wick, the water evaporates into the air, leaving behind any white dust, minerals, or dissolved and suspended solids. Because the water is evaporated, there is just clean and invisible moist air. As the evaporative wick traps accumulated minerals from the water, its ability to absorb and evaporate water decreases. We recommend changing the wick at the beginning of every season. In hard water areas, more frequent replacement may be necessary to maintain your humidifier’s ef ficiency. Use only Essick Air brand replacement wicks and chemicals. To order parts , wicks and chemicals call 1-800-547-3888. The 700 Series humidifiers use Essick Air wick # 1040. Only the Essick Air evaporative wick guarantees the certified output of your humidifier. Use of wicks other than Essick Air brand will void your warranty as well as the certification of output and may reduce the efficiency of your humidifier.
CAUTION: Do NOT position the unit directly in front of a hot air duct or radiator. Do NOT place on soft carpet. We suggest placing the unit on a table or on a bookshelf.
ASSEMBLY, CONTROLS & OPERATION ASSEMBLY
1) Unpack humidifier from carton and remove all packaging material, wicks, etc. from box. Remove foam from bottle.
2) Place the humidifier “cabinet” with evaporative wick at the location where the product will be operated at least 4 inches from the wall. Fill bottle to capacity of 1 ¾ gallons, replace cap and tighten securely. Using bot h hands to carry the bottle to the base. NOTE: If only softened water is available, it can be used; however you will notice a build up of minerals on the evaporative wick much sooner. Do not spill water on fan motor. Electrical components must be
kept dry.
3) Make sure wick is resting all the way into the
water channel as making sure the wick is resting all the way into the water channel..
4) Return bottle to its upright position using the handles on
the top of the bottle. Set the bottle in the recessed area, the top of the bottle flush with the top of the humidifier.
See illustration. When positioned properly, the valve will
open and water will flow into the water channel.
5) We recommend using Essick Air Bacteriostat Treatment
whenever you refill the humidifier reservoir to eliminate bacterial growth. Add bacteriostat according to the instructions on the bottle.
6) Plug cord into wall receptacle and turn humidifier on.
louvered and may be rotated 360 degrees to direct the airflow where you want it.
**When excessive condensation exists, a lower speed setting is recommended.
CAUTION: Disconnect power before filling, cleaning or servicing unit. Keep grille dry at all times.
OPERATION & CONTROLS –
1) The humidifier should be placed at least FOUR inches away from any walls and
away from heat registers. Do not place on soft carpet. Unrestricted airf low into the unit will result in the best efficiency and performance. Set desired levels and speed.
2) Model 736 200 only- has an humidistat. (The humidistat control knob is located on the right). The humidistat will turn the humidifier on when the relative humidity in your home is below the humidistat setting and will turn the humidifier off when the relative humidity reaches the humidistat setting. For initial operation, set the humidistat at its midpoint a nd adjust up or down from there to achieve the desired humidity level.
indicated by the illustrations,
700 Wick Placement
Note The outlet grille is
automatic
700 Bottle Placement
Loading...