To order parts and accessories call 1-800 547-3888
Other Patents Pending
French and Spanish
instructions included.
Se incluyen instrucciones
en Español y Francés.
Directives en français et
en espagnol compris.
586 4140 Rev.4/04
Important Safeguards
READ BEFORE USING YOUR HUMIDIFIER
1) This appliance has a polarized plug (one blade is wider than the other).
To reduce the risk of electric shock, this plug is intended to fit into a
polarized 120-volt AC, 15 amp outlet, only one way. If the plug does
not fit fully in the outlet, reverse the plug. If it still does not fit, contact a
qualified electrician. Do not attempt to defeat this safety feature. If an
extension cord
and meet this electrical rating.
2) Do not place the cord under rugs, in traffic areas, or near heat sources.
3) Do not use the humidifier if the cord is damaged.
4) Always unplug the power cord before filling, cleaning,
servicing, or when the unit is not in use.
5) Care must be used when filling. Remove top grille and fill through the
left opening between wick and sidewall of cabinet. Any water spilled
on chassis must be dryed before energizing humidifier.
6) Do not place the humidifier near loose drapes, combustible materials, or
heat-producing objects.
7) This humidifier is UL listed with Bemis by Essick Air brand evaporative
wicks in place. To maintain your UL rating, see your service center for
all repairs. Use only Bemis by Essick Air brand replacement wicks and
chemicals. To order parts, wicks and chemicals call 1-800-547-3888.
8) It is very important that cleaning solutions such as bleach, bacteria treatment or descaler, which could be used to clean the cabinet, are not
sprayed or applied to the chassis assembly. These solutions can cause
serious electrical malfunction of the humidifier.
must be used, it should also accept the wide blade plug
Introduction
Your Bemis by Essick Air evaporative humidifier adds invisible moisture to your
home by moving dry inlet air through a saturated wick. As air moves through
the wick, the water evaporates into the air, leaving behind any white dust, minerals or dissolved and suspended solids. Because the water is evaporated, there
is no messy mist or spray and no white dust, just clean and invisible moist air.
As the evaporative wick traps accumulated minerals from the water, its ability
to absorb and evaporate water decreases. W
at least once a year
humidifying season and starting with a new one at the beginning of the next
humidifying season. In hard water areas, more frequent replacement may by
necessary to maintain your humidifier's efficiency.
, preferably disposing of the used one at the end of the
e recommend changing the wick
CAUTION-We recommend using Bemis by Essick Air Bacteria Treatment when
ever you refill the water bottles to eliminate bacteria growth. Follow the directions to determine the proper amount to be added to the 3 gallon reservoir.
The wick does not requir
that are intended for use in Rotobelt or Water Wheel type humidifiers
Locate your humidifier on an inside wall, near an electrical outlet. The
humidifier should be at least 4" away from the wall for best results. Do not
position the unit directly in front of a hot air duct or radiator.
e the use of chelating agent type water treatments
.
Clean, Space Saver moisturizing.
Dry air is drawn into the unit and
washed with water as it passes
through the moistened wick and
out into the room to provide a
comfortable spring fresh moistened
atmosphere.
Assembly, Filling & Operation
ASSEMBLY:
1) Unpack humidifier from carton.
2) Remove all packaging
material, wicks, etc. from cabinet.
3) The wicks are located by four
pairs of ribs in the bottom of
the cabinet. Locate the two
wicks. Insert them by dropping each one down into the locating ribs
(see illustration).
4) After inserting the wicks, place the transition molding on top of them,
flange side up. The notch along one side of the transition goes to the
back of the cabinet.
5) Place the chassis unit into the cabinet, with the switch to the back and
hang it onto the mounts at the front and back inside of the cabinet.
FILLING:
6) Before replacing the top grille, fill the reservoir with cool, fresh, preferably
unsoftened water
CHASSIS. Fill the cabinet only through the opening between the left
wick and the cabinet sidewall, to the level marked “Fill to Here” on
the left side rear wall of the cabinet. If water spills on the chassis, it must
. DO NOT POUR WATER OVER THE ELECTRICAL
Assembly, Filling and Operation(cont.)
be allowed to dry completely before energizing the humidifier. If
you have only softened water available in your home, you can use
it, but you will notice a build up of minerals on the evaporative
wicks much sooner. Reservoir capacity is 3.0 gallons.
DO NOT OVERFILL
7)
We recommend using Bemis by Essick Air Bacteria Treatment, whenever
you refill the humidifier reservoir to eliminate bacterial growth.
Add bacteriostat according to the instructions on the bottle.
8) Replace the grille onto the cabinet with the switch opening to the back.
OPERATION:
9) Plug cordset into interlock receptacle at back of unit.
10) Plug cordset into wall receptacle.
11) Turn Humidifier on.
12) The amount of humidity is regulated by using the HI/LO speed switch
on the chassis.
Air Care®Filters
The 527 300 features a two-stage air filter inserted into the top of the
power pak which filters the air as it humidifies.
The first stage of the air filter is 3M FIlTRETE
a high-efficiency, electrostatically-charged
filter media which traps dust, pollen and
airborne pollutants. The second stage of the
Air Care filter is an activated carbon media
which absorbs odors from cooking, pets or
tobacco smoke.
We recommend replacing the Air Care filter
at least once a year, more often if necessary.
When the white filter media is coated with a
layer of dust and dirt, it is time to replace the filter.
The certified water output of your humidifier will be reduced when using
the Air Care filter.
Air Care filters are optional and are not required for normal operation of
the humidifier.
*FILTRETETMis Trademark of 3M Corp.
TM,
Care and Maintenance
IMPORTANT: We recommend cleaning your humidifier once a week. Follow
instructions.
Humidifiers provide comfort by adding moisture to dry, heated indoor air.
To get the most benefit from the humidifier and avoid product misuse, follow all instructions carefully, specifically the filling operation, care and
maintenance guidelines. Please note this is an electrical appliance and
requires careful attention when in use.
Keep the chassis dry at all times.
In addition, if you do not follow the recommended care and maintenance
guidelines, microorganisms may be able to grow in the water within the
humidifier's reservoir.
Caution: Disconnect power before filling, cleaning or servicing unit.
CLEANING/DISINFECTING INSTRUCTIONS
1) Turn unit off.
2) Unplug electrical cord from the
wall outlet.
3) Unplug interlock plug from
chassis receptacle.
4) Lift off grille
5) Lift chassis unit from cabinet
and set aside
REMOVING SCALE
6) Carefully lift wicks from cabinet,
allowing any water to drain
from wicks into cabinet.
7) Empty cabinet into sink. Remove
any remaining water from
cabinet with a sponge. Fill
reservoir with one 8 oz. cup of
undiluted white vinegar.
Let solution stay 20 minutes.
Clean all interior surfaces of
reservoir with a soft brush.
Dampen soft cloth with a
undiluted white vinegar
and wipe out reservoir to
remove scale.
8) Rinse cabinet thoroughly with
fresh water to remove scale &
cleaning solution before
disinfecting.
Cont. next page
Care and Maintenance (cont')
DISINFECTING RESERVOIR
9) Fill reservoir with mixture of one
teaspoon chlorine bleach in one
gallon water. Let solution stay
20 minutes, swishing every few
minutes. Wet all surfaces inside
the reservoir. DO NOT
ALLOW BLEACH OR
CLEANING SOLUTION TO
REACH THE CHASSIS OR
ANY ELECTRICAL COMPONENT. THIS COULD CAUSE
SERIOUS ELECTRICAL
MALFUNCTION.
10) Empty reservoir after 20
minutes. Rinse with water until
bleach smell is gone. Dry with
clean cloth or paper towel.
11) Replace wicks in cabinet by
dropping wicks into locating
ribs in bottom of cabinet.
12) Replace transition molding on
top of the wicks.
13) Replace chassis unit into
cabinet, with switch to the back,
ensuring that the chassis seats
correctly on the front and back
edge of the cabinet.
14) Plug cord set into interlock
receptacle at back of unit. Plug
cord set into wall outlet. Turn
unit on.
EVAPORATIVE WICKS
15)
We recommend replacing the wicks
at least once a season, more often
in hard water areas. When they
appear excessively clogged with
mineral deposits, discard them and
restore your humidifier's efficiency
with new wicks. Bemis by Essick
Air wick number 1040 fits all 500
Series Tabletop humidifiers. For
replacement wicks,
call 1-800-547-3888.
Only the Bemis by Essick Air
evaporative wick guarantees
the
certified output of your
humidifier.
than Bemis by Essick Air brand
will void your warranty as well
as the certification of output and
may reduce the efficiency and
output of your humidifier.
Use of wicks other
Summer Storage
1) Clean unit as outlined in Care
&
Maintenance section.
2) Discard used wicks-install new
Bemis by Essick Air evaporative
wicks at the beginning of the
next season. Only Bemis by
Essick Air wicks guarantee the
rated output of your humidifier.
3) Allow unit to dry thoroughly
before storage. Do not store
with water inside reservoir.
4) Do not store unit in an attic or
other high-temperature area.
5) Clean humidifier and install
new filter before next
season begins.
6) A convenient order form for
wicks and accessories is found
in the back of this manual.
Accessories
Evaporative Wick
Model 1040. Each portable humidifier
requires two evaporative wicks. Each wick
continuously wicks up moisture as it traps
mineral deposits. Only Bemis by Essick Air
wicks guarantee the rated performance from
your Bemis by Essick Air Evaporative Humidifier
Air Care®Filter
Model 1050. Replaceable two-stage Air Care
filter 3M FiltreteTMremoves airborne particles
and activated carbon removes odors.
Bacteria Treatment
No.1970-32 oz. Bacteria Treatment.
Controls bacteria growth in humidifiers. Helps
eliminate unpleasant odors.
.
Humidifier
Descaler/Cleaner
No. 1961-32 oz. Descaler/Cleaner.
Bemis by Essick Air Humidifier Descaler will
clean and prepare your humidifier for efficient
operations by removing any lime scale
build-up or sediment.
HOME COMFORT DIVISION
ONE-YEAR LIMITED WARRANTY
The Bemis by Essick Air humidifier warranty covers defects in materials and workmanship for a period of one year from date of retail purchase. This warranty applies only
to the original purchaser of the product.
Within the first 12 months from date of purchase, Essick Air will repair or replace, at its
discretion, any defective part of the humidifier covered by this warranty.
This warranty gives you specific legal rights, and you may also have other rights which
vary from state to state or province to province.
This warranty does not cover damage resulting from misuse or abuse of the humidifier, accidents or alterations to the product, commercial use or damage during shipment.
Misuse includes malfunctions caused by negligence in cleaning or parts fouled with mineral deposits due to hard-water conditions. Alterations to the product include the substitution of non-Bemis by Essick Air brand components including, but not limited to, wicks.
If service becomes necessary, take or send the product to any Bemis by Essick Air
service center.
Essick Air Products
5800 Murray Street
Little Rock, AR 72209
501.562.1094
To keep your humidifier in top working condition, use only Bemis by Essick Air replacement parts. Only Bemis
ACCESSORY ORDER FORM
by Essick Air replacement wicks guarantee your humidifier will maintain its original AHAM certified output.
Replacement Wick Filter for
Summer Protective
No. SGL1040
Single Pack Wick for
300, 500, & 700 Series
Tabletop Humidifiers
300, 500, & 700 Series
Tabletop Humidifiers
• Helps Eliminate Bacteria & Algae Build-up
• Strongly Recommended for Bemis Humidifiers
& All Other Evaporative Humidifiers
900 Series
Tabletop Humidifiers
No. H7000
Dust Cover for
700 Series
$4.99
$7.49
No. 1040
Twin Pack Wick for
$12.99
Bacteria Treatment, 32 oz.
No. 1044
$5.49
No. 1970
$5.99
Item #DescriptionQtyPriceAmount
1040Twin Pack Wick for 300, 500, &, 700 Tabletop Humidifiers$ 12.99
SGL1040 Single Pack Wick for 300, 500 & 700 Tabletop Humidifiers$ 7.49
1044Replacement Wick Filter for 900 Series Tabletop Humidifiers$ 5.49
1050Air Cleaner Filter for 500 Series Tabletop Humidifiers$ 7.99
1052SGL Air Cleaner for 700 Series Tabletop Humidifiers$ 5.99
1053Twin Pack Air Cleaner Filter for 300 Series Tabletop Humidifiers$ 12.99
1961Cleaner for all Humidifiers, 32 oz.$ 3.99
1970Bacteria Treatment, 32 oz.$ 5.99
H7000 Summer Protective Dust Cover for 700 Series$ 4.99
1990Digital Hygrometer/Comfort Sensor$ 25.99