DANGER: means if the safety information is not followed someone will be
seriously injured or killed.
WARNING: means if the safety information is not followed someone could be
seriously injured or killed.
CAUTION: means if the safety information is not followed someone may be
injured.
1. To reduce the risk of fire or shock hazard, this humidifier has a polarized plug
(one blade is wider than the other). Plug humidifier directly into a 120V, A.C.
electrical outlet. Do not use extension cords. If the plug does not fully fit
into the outlet, reverse plug. If it still does not fit, contact a qualified electrician
to install the proper outlet. Do not change the plug in any way.
2. Keep the electric cord out of traffic areas. To reduce the risk of fire hazard,
never put the electric cord under rugs, near heat registers, radiators, stoves
or heaters.
3. Always unplug the unit before moving, cleaning or removing the fan assembly
section from the humidifier, or whenever it is not in service.
4. Keep the humidifier clean.To reduce the risk of injury, fire or damage to
humidifier, use only cleaners specifically recommended for humidifiers. Never
use flammable, combustible or poisonous materials to clean your humidifier
5. Do not put foreign objects inside the humidifier.
6. Do not allow unit to be used as a toy. Close attention is necessary when used
by or near children.
7. To reduce the risk of electrical hazard or damage to humidifier, do not tilt, jolt
or tip humidifier while unit is running.
8. To reduce the risk of accidental electrical shock, do not touch the cord or
controls with wet hands.
9. To reduce the risk of fire, do not use near an open flame such as a candle or
other flame source.
WARNING: For your own safety, do not use humidifier if any parts are
damaged or missing.
WARNING: To reduce risk of fire, electric shock, or injury always unplug
before servicing or cleaning.
WARNING:To reduce the risk of fire or shock hazard, do not pour or spill
liquid into control or motor area. If controls get wet, let them dry completely
and have unit checked by authorized service personnel before plugging in.
2
INTRODUCTION
Your new humidifier adds invisible moisture to your home by moving dry inlet air
through a saturated wick. As air moves through the wick, the water evaporates into
the air, leaving behind any white dust, minerals, or dissolved and suspended solids.
Because the water is evaporated, there is just clean and invisible moist air.
As the evaporative wick traps accumulated minerals from the water, its ability to
absorb and evaporate water decreases. We recommend changing the wick at the
beginning of every season. In hard water areas, more frequent replacement may
be necessary to maintain your humidifier’s efficiency.
Use only AIRCARE
order parts, wicks and chemicals call 1-800-547-3888. This humidifier uses two
wicks # 1040. Only the AIRCARE® or Essick Air® evaporative wick guarantees the
certified output of your humidifier. Use of other brands of wicks voids the
certification of output and may void your warranty.
HOW YOUR HUMIDIFIER WORKS
Your new evaporative humidifier is designed
to satisfy home humidity requirements
through the principle of evaporation of water
in the air.
Once the wick becomes saturated, air is
drawn in, passes through the wick and
moisture is absorbed into the air. All
evaporation occurs in the humidifier so any
residue remains in the wick.
This natural process of evaporation creates no white dust like some other humidifiers.
Water Capacity 3 Gallons
Sq. ft. coverage
Fan Speeds 4
Replacement Wicks (2 required) 1040
Auto Humidistat Yes
Controls Digital
ETL Listed Yes
Volts 120
Hertz 60
Watts 40
* Based on an area with average insulation and an 8’ ceiling height.
NOTES ON LOCATION
In order to get the most effective use from your humidifier, it is important to
position the unit where the most humidity is needed or where the moist air will be
circulated throughout the house such as near a cold air return. If the unit is
positioned close to a window, condensation may form on the window pane. If this
occurs the unit should be repositioned in another location.
Do NOT position the unit directly in front of a hot air duct or radiator. Do NOT
place on soft carpet.
Due to release of cool, moist air from the humidifier, it is best to direct air away
from thermostat and hot air registers. Position humidifier next to an inside wall on
a level place at least 4 inches away from the wall or curtains.
®
or Essick Air® brand replacement wicks and chemicals. To
Description3D6 100
1800 (Tight Constr.)
1200 ( Avg. Constr.)
:
3
ASSEMBLY
1) Unpack humidifier from carton.
2) Remove all packaging material from humidifier.
3) Remove bottles from base.
4) REMOVE PLASTIC WRAP FROM WICKS IF NECESSARY.
RIGHT WATER BOTTLE
BASE
FAN GRILLE
(AIR EXIT)
AIR INTAKE LOUVERS
WICK
HOUSING
WATER BOTTLE VALVE
LEFT WATER BOTTLE
BOTTLE CAP
Replacement Parts Available for Purchase
Description Part Number
Chasis 1B72701
Left water bottle 1B71937L
Right water bottle 1B71937R
Bottle caps 1B71780
Wicks (2) 1040
Manual (not shown) 1B72878
To order parts and accessories pleas call 1-800-547-3888. Please have
humidifier serial number when you call.
WATER FILL
CAUTION: Before filling, ensure unit is turned OFF and unplugged.
NOTE: Unit will continue running, even when out of water.
1) Remove water bottles
and unscrew caps on
bottom. Fill bottle with
unsoftened water.
Replace caps and
tighten securely. Use
both hands to carry
each bottle to the base.
NOTE: If only softened
water is available, it can be used; however you will notice a build-up of minerals
on the evaporative wick much sooner.
2) Return bottle to its upright position using the handle on the top of the bottle.
Set the bottle in the recessed area with the top of the bottle flush with the top
of the humidifier. When positioned properly, the valve will open and water will
flow into the water channel.
4
CAUTION: Do not spill water on fan motor. Electrical components must be
kept dry.
ABOUT HUMIDITY
Where you set your desired humidity levels depends on your personal comfort
level, the outside temperature and the inside temperature.
NOTE: Recent CDC tests show that the chances of flu transmission are greatly
reduced at levels of 43% humidity.
You may wish to purchase a hygrometer* to measure the humidity level in your
home. The following is a chart of recommended humidity settings. NOTE: We
recommend using AIRCARE® or Essick Air® Bacteriostat Treatment when you
refill the water reservoir to eliminate bacterial growth. Add bacteriostat according
to the instructions on the bottle.
Under no circumstances should you use Water Treatment products intended for
Rotobelt or Ultrasonic humidifiers.
IMPORTANT: Water damage
may result if condensation
starts to form on windows or
walls. Humidity SET point
should be lowered until
condensation no longer forms.
We recommend room humidity
levels do not exceed 50%.
*Model 1990 digital hygrometer is available for purchase by calling 1-800-547-3888.
NOTE: External hygrometer readings and humidistat readings may differ.
Humidity levels can vary significantly even in one room.
OPERATION
Plug cord into wall receptacle. Your humidifier is now ready for use. The humidifier should
be placed at least FOUR inches away from any walls and away from heat registers.
Unrestricted airflow into the unit will result in the best efficiency and performance.
NOTE: This unit has an automatic humidistat located on the cord that senses the
humidity level around the immediate area of the humidifier. It turns the humidifier on when
the relative humidity in your home is below the humidistat setting and will turn the
humidifier off when the relative humidity reaches the humidistat setting.
DIGITAL DISPLAY
TO TURN ON/OFF
For initial operation, plug the unit
in (the display will show - -). Press
the speed button and hold for 5
seconds to turn the unit on or off.
FAN SPEED
The 3D6100 has a four speed
digital control panel.
PRESS TO
INCREASE
HUMIDITY
PRESS AND HOLD
TO TURN UNIT ON
PUSH TO ADJUST
FAN SPEED
1) Press the SPEED button to
adjust the fan speeds.
2) The speeds: High (F4) - Low
(F1) display on the digital panel.
5
HUMIDITY CONTROL
3) The hygrometer on the cord reads the current room humidity and displays the
percentage on LCD panel.
4) To set the desired humidity, press the HUMIDITY button. Each successive
push increases the humidity in 5% increments. The range is 25% to 65%.
5) At 65% the humidifier will run constantly with or without water.
NOTE: If excessive condensation occurs, reduce fan to a lower speed setting.
CHECK FILTER
The ability of any humidifier to efficiently supply humidity output relies heavily on the
condition of the filter. As the filter loads with impurities it gradually loses its wicking
capability. When this happens, moisture output is reduced and the humidifier has to work
longer to satisfy the selected setting.
1) This humidifier has a check filter reminder timed to appear after
720 hours of operation. When the Check Filter (CF) message is
displayed, disconnect the power cord and check the condition of
the filter. If a build-up of deposits or severe discoloration is
evident replace the filter to restore maximum efficiency.
2) The CF function is reset after plugging the unit back in.
Check Filter
Function Display
CONTROL LOCK FEATURE
To avoid unwanted tampering with the humidifier settings the
controls can be locked.
Control Lock
Display
ACTIVATION PROCEDURE
After the humidifier functions have been set up, hold the Speed and
Humidity buttons down for 5 seconds. The display will show “CL”
for 2 seconds;
Release the buttons and the control will resume the display of the room humidity.
The humidifier will continue to function with the locked in settings. If buttons are
operated while “CL” is active, the “CL” is displayed and settings are unaffected.
DEACTIVATION PROCEDURE
To deactivate the “CL” function simply press and hold both buttons for 5
seconds. “CL” will flash at the rate of 1 second on and 1 second off for a period
of 2 seconds and then resume the display of room humidity.
REPLACEMENT OF WICK
CAUTION: Before changing wick, ensure unit is turned OFF and unplugged.
NOTE: This unit uses 2 model 1040 wicks. Replace the wick at the beginning of
each season, and more often in areas with hard water.
Remove water bottles from the humidifier and place them in a secure place. Locate
the two internal spring latches on the front and rear of the base. Releasing these
latches will allow removal of the top housing.
1) Flex the rear latch and lift the back of the top housing off the base far enough to
clear the latch. Flex the front latch and lift the complete top housing away from the
base. Place the top housing on a flat surface.
6
CARE AND MAINTENANCE
Cleaning your humidifier regularly helps eliminate odors and bacterial and
fungal growth. Ordinary household bleach is a good disinfectant and can be used to
wipe out the humidifier base and bottle/reservoir after cleaning .We recommend
cleaning your humidifier at least once every two weeks to maintain optimum
environmental conditions for your home. We also recommend using AIRCARE
Essick Air
eliminate bacterial growth. Add bacteriostat according to the instructions on the
bottle. Please call 1-800-547-3888 to order Bacteriostat Treatment, part number 1970.
REMOVING SCALE
1) Turn off unit and unplug from outlet.
2) Remove water bottles from the humidifier and place it with the cap up in a
3) Carry base to sink and wash it following the instructions in the and
4) Lift the wicks from the base allowing excess water to drain.
5) Rinse wicks under freshwater only. Do not use soap, detergent, or any other
6) Empty the water from the base and water bottles. Fill the base and water
7) Dampen a soft cloth with white vinegar and wipe out water bottles and base to
DISINFECTING UNIT
8) Fill the water bottles and base with water and adding 1 teaspoon of bleach to
9) Refill unit and re-assemble per ASSEMBLY instructions.
UMMER STORAGE
®
Bacteriostat Treatment each time you refill your humidifier to
secure location. Locate the two internal spring latches on the front and rear of
the base. Releasing these latches will allow removal of the top housing. Flex
the rear latch and lift the back of the top housing off the base far enough to
clear the latch. Flex the front latch and lift the complete top housing away
from the base. Place the top housing on a flat surface.
DISINFECTING UNIT sections below.
cleaners on the wicks. Leave in sink to drain.
bottles with water and add 8 oz. (1 cup) of white vinegar. Let stand 20
minutes. Then empty solution.
remove scale. Rinse the water bottles and base thoroughly with fresh water
to remove scale and cleaning solution before disinfecting.
each bottle. Dampen a soft cloth with solution and wipe all surfaces on water
bottles and base. Let solution stay for 20 minutes, then rinse with water until
bleach smell is gone. Dry with clean cloth. The outside of the unit and water
bottle may be wiped down with a soft cloth dampened with fresh water.
®
or
1) Clean unit as outlined in Care & Maintenance section.
2) Discard used wicks and any water in the reservoir and allow cabinet to
dry thoroughly before storage. Do not store with water inside reservoir.
3) Do not store unit in an attic or other high-temperature area, as damage will
occur.
4) Install new filter at beginning of season.
7
HUMIDIFIER TWO YEAR LIMITED WARRANTY POLICY
SALES RECEIPT REQUIRED AS PROOF OF PURCHASE FOR ALL
WARRANTY CLAIMS.
This warranty is extended only to the original purchaser of this humidifier when the
unit is installed and used under normal conditions against defects in workmanship
and materials as follows:
Two (2) years from date of sale on the unit, and
Thirty (30) days on wicks and filters, which are considered disposable
components and should be replaced periodically.
The manufacturer will replace the defective part/product, at its discretion, with
return freight paid by the manufacturer. It is agreed that such replacement is the
exclusive remedy available from the manufacturer and that TO THE MAXIMUM
EXTENT PERMITTED BY LAW, THE MANUFACTURER IS NOT RESPONSIBLE
FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND
CONSEQUENTIAL DAMAGE OR LOSS OF PROFITS OR REVENUES.
Some states do not allow limitations on how long an implied warranty lasts, so the
above limitations may not apply to you.
Exclusions from this warranty
We are not responsible for replacement of wicks and filters.
We are not responsible for any incidental or consequential damage from any
malfunction, accident, misuse, alterations, unauthorized repairs, abuse, including
failure to perform reasonable maintenance, normal wear and tear, nor where the
connected voltage is more than 5% above the nameplate voltage.
Alterations include the substitution of name brand components including, but not
limited to wicks and bacteria treatment.
We are not responsible for any damage from the use of water softeners or
treatments, chemicals or descaling materials.
We are not responsible for the cost of service calls to diagnose the cause of
trouble, or labor charge to repair and/or replace parts.
No employee, agent, dealer or other person is authorized to give any warranties or
conditions on behalf of the manufacturer. The customer shall be responsible for all
labor costs incurred.
This warranty will be null & void if purchaser attempts to repair or replace any parts
which are mechanical or electrical.
Some states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitations or exclusions may not apply to you.
How to obtain service under this warranty
Within the limitations of this warranty, purchaser with inoperative units should
contact customer service at 800-547-3888 for instructions on how to obtain service
within warranty as listed above.
This warranty gives the customer specific legal rights, and you may also have other
rights which vary from province to province, or state to state.
Register your product at www.essickair.com or www.AIRCAREproducts.com.
8
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.