This manual contains information on limitations regarding product use and function
and information on the limitations as to liability of the manufacturer.
The entire manual should be carefully read!
WARNING
General Information
The system is to be installed by a qualied person to the latest Fire Alarm and
Installation Regulations which are mandatory in the applicable country of installation.
Before commencing the installation of this Fire Alarm Panel, ensure it is sited in a
position, which is visible to the Fire Brigade when entering the premises, and where
ease of access is provided for users and service engineers. Space must be available
to easily open external and internal doors.
The Electrical Supply to the panel must be isolated and must not be capable of being
accidentally switched off. A ‘Lockable Switch fuse Unit’ positioned within 2 meters of
the panel should be clearly labelled FIRE ALARM - DO NOT SWITCH OFF.
EN 54-2 compatible panels.
All specications are subject to change without notice.
Technical Support help:
+44 (0) 1527 51 51 50
Fire Control Panel MAG2 / MAG4 - User Manual 3
CONTENTS
General Information ....................................................................................2
During the guarantee period the manufacturer shall, at its sole discretion, replace or repair any defective product
when it is returned to the factory. All parts replaced and/or repaired shall be covered for the remainder of the
original guarantee, or for ninety (90) days, whichever period is longer. The original purchaser shall immediately
send manufacturer a written notice of the defective parts or workmanship, which written notice must in all cases
be received prior to expiry of the guarantee.
International Guarantee
Foreign customers shall enjoy the same guarantee rights as those enjoyed by any customer in Bulgaria, except
that manufacturer shall not be liable for any related customs duties, taxes or VAT, which may be payable.
Guarantee Procedure
This guarantee will be granted when the appliance in question is returned. The manufacturer shall accept no
product whatsoever, of which no prior notice has been received.
Conditions for waiving the guarantee
This guarantee shall apply to defects in products resulting only from improper materials or workmanship, related
to its normal use. It shall not cover:
§ Damages resulting from improper transportation and handling;
§ Damages caused by natural calamities, such as re, oods, storms, earthquakes or lightning;
§ Damages caused by incorrect voltage, accidental breakage or water; beyond the control of the manufacturer;
§ Damages caused by unauthorized system incorporation, changes, modications or surrounding objects:
§ Damages caused by peripheral appliances (unless such peripheral appliances have been supplied by the
manufacturer:
§ Defects caused by inappropriate surrounding of installed products;
§ Damages caused by failure to use the product for its normal purpose; Damages caused by improper
maintenance;
§ Damages resulting from any other cause, bad maintenance or product misuse.
In the case of a reasonable number of unsuccessful attempts to repair the product, covered by this guarantee, the
manufacturer’s liability shall be limited to the replacement of the product as the sole compensation for breach of the
guarantee. Under no circumstances shall the manufacturer be liable for any special, accidental or consequential
damages, on the grounds of breach of guarantee, breach of agreement, negligence, or any other legal notion.
Waiver
This Guarantee shall contain the entire guarantee and shall be prevailing over any and all other guarantees,
explicit or implicit (including any implicit guarantees on behalf of the dealer, or adaptability to specic purposes),
and over any other responsibilities or liabilities on behalf of the manufacturer. The manufacturer does neither
agree, nor empower, any person, acting on his own behalf, to modify or alter this Guarantee, nor to replace it with
another guarantee, or another liability with regard to this product.
Unwarranted Services
The manufacturer shall repair or replace unwarranted products, which have been returned to its factory, at its sole
discretion under the conditions below. The manufacturer shall accept no products for which no prior notice has
been received.
The products, which the manufacturer deems repairable, will be repaired and returned. The manufacturer has
prepared a price list and those products, which can be repaired, shall be paid for every repaired appliance.
The closest equivalent product, available at the time, shall replace the products manufacturer deems unrepairable.
The current market price shall be charged for every replaced product.
Fire Control Panel MAG2 / MAG4 - User Manual 5
Using the MAG2 / MAG4 Controls
!
• Refer to the instructions on the inside of the outer door.
Indications / Outputs
NORMAL: • The green LED next to the ‘power Supply 230V AC’ will be
illuminated.
FIRE:• Two integrated red status FIRE LED’s and a zone identication LED
will ash together on receipt of a FIRE condition and become steady
after the Silence Alarm button is pressed.
• An internal buzzer will operate until silenced.
• The external sounders will operate.
• The FIRE relay will energize.
FAULT:• A yellow General Fault LED will always illuminate together with an
external or internal identication LED.
• An internal buzzer will sound.
• The FAULT relay will de-energize.
Faults are monitored as follows:
IndicationFault description
○ 1 / ○ 2 / ○ 3 / ○ 4Zone fault - open or short circuit. Detector head removed.
○ µPProcessor break down.
○ Sounder 1
○ Sounder 2
○ +24V DC Overload Overload of “+24” VDC power supply.
○ +24V DC Failed Absence of “+24” VDC power supply.
○ Battery Low Low battery condition.
○ Battery Lost Battery loss.
○ ACMains Supply loss.
○ Charger Battery charger fault.
○ AUX Auxiliary supply fault.
○ Earth Short circuit to earth.
NOTE: Fault conditions will not be announced instantly. There will be a short delay which
will vary from condition to condition. Faults when cleared will automatically reset at the
panel.
Sounder Circuit One fault - open or short circuit, reverse connected
sounder, or bad sounder parameters.
Sounder Circuit Two fault - open or short circuit, reverse connected
sounder, or bad sounder parameters.
Engineers Facilities:
MAG2 / MAG4 has the ability to select various facilities to assist the engineer during
installation and testing of the system. These facilities include:
Zone Test- Individual zones can be tested and activated without the need to return to the panel to effect a RESET. This is done
automatically by the panel.
Isolate Sounders - System can be tested without operating the Sounder
circuits.
Disable / Enable Zone - Each zone can be disabled / enabled.