ESP EV-ML-500XT Installation Instructions

Page 1
EV-ML-500XT
EXTERNAL I P R ATE D 5 0 0 KG MAG N E T I C LOCK
Page 2
EV-ML-500XT Diagram
Armature Screw
Armature Plate
Blind Nut
Cable
Door Spacer
Sexnut Bolt
Rubber Washer
Fixing Screw
Anti-tamper Cap
Mounting Confi gurations
Please identify the type of installation required, for example; which way the door/gate will swing. Refer to the installation diagrams for the blind nut, magnetic lock, bracket & armature to complete the install.
Standard mounting
Surface mounted electromagnetic lock with door mounted armature.
Door
Out-swinging
‘Z’ Bracket mounting
Face mounted electromagnetic lock with ‘Z’ Bracket mounting.
Door Frame
Door Frame
EM Lock
Armature Plate
Armature Plate
EM Lock
‘L’ Bracket mounting
‘L’ Bracket mounted electromagnetic lock with door mounted armature.
Out-swinging
Door Frame
Door
Adjustable
‘L’ Bracket
EM Lock
Armature Plate
Swinging gate
Face mounting electromagnetic lock with ‘Z’ Bracket mounting configuration for armature.
Post Post
Door
In-swinging
‘Z’ Bracket Set
Swinging Gate
Magnet
Armature Plate
‘Z’
Bracket
Page 3
Sliding gate
Face mounting electromagnetic lock.
Armature
Plate
Post Post
Magnet
Installation Instructions
Blind nut installation x2
9.4mm holes for M6 Blind Nuts
Blind Nuts
Allen Key
Blind nut and electromagnetic lock installation
Sliding Gate
Surface Mount
Fixing Screw
Blind nut and bracket installation
‘L’ Bracket con figuration
Cap Nut
Blind Nut
EM Lock
M6x30
M6x30
Fixing Screw
Face Mount
‘Z’ Bracket configuration
M6
M6x30
M8x25
M5x10
Blind Nuts
Page 4
Armature installation
Armature Door Mount Armature Bracket Mount
Door Frame
Armature
Rubber Washer
Steel Washer
Sexnut
Bolt
Wiring configuration
It is recommended to install the electromagnetic lock inside the property and conceal the cable inside the door frame to avoid unlawful entry.
Voltage Selection: 12 VDC
Yellow
Green
White
Brown
Control Device
N.C. contact or Access Relay
Power
Supply
Rubber washer installation
The rubber washer allows the armature plate to pivot to compensate for door misalignment.
Rubber Washer
Fig. 8
Voltage Selection: 24 VDC
Yellow
Green
White
Brown
Control Device
N.C. contact or Access Relay
Power Supply
Technical Specifications
Holding force 500kg / 1100lbs max
Housing Stainless Steel
Weather resistant rating IP67
Dual voltage 12 & 24 VDC
Current drawn 420mA @ 12VDC
240mA @ 24VDC
Safety approval CE
Magnet Dimension 220(L) x 62(W) x 43(D)mm
Armature Plate Dimension 185(L) x 61(W) x 17(D)mm
Telephone: 01527 515150 www. e spuk. com